SQUARE D

Meter mains, Homeline, CSED, ringless socket, 400A, surface mount, maximum 8 spaces, 16 circuits, Class 320 with lever bypass

HPP - 400A 120/240 1PH 8 CKT

SQDRC816D400SL RC816D400SL 785901335276
1207.03 / EA
http://schema.org/OutOfStock
  • Certifications: UL E-6294
  • Depth: 7.89 in
  • Height: 32.68 in
  • Line Rated Current: 400 A
  • Mounting Type: Surface
  • Number of Circuits: 16
  • Number of Phases: 1
  • Width: 28 in
Square D™ Meter Mains are single phase power distribution panels used in residential applications where local codes require service disconnects to be located outside the dwelling. The meter socket supports a standard utility meter and a main disconnect breaker which provides a time and space saving solution for contractors and installers. Meter mains are surface mount with provisions. This is for the field installation of the service disconnect(s) that feed devices downstream. Interior subfeed load centers are typically used with these. This CSED is a Homeline ringless type with horn bypass, and combination overhead/underground feed. With a current rating of 400A, this product has a short circuit current rating of 22kA. Single main service disconnects option is also available. Devices meet the Electric Utility Service Equipment Requirements Committee (EUSERC) standards, Federal Specifications W-P-115C for government housing.
QTY
  • Product Description
  • Specifications
Square D™ Meter Mains are single phase power distribution panels used in residential applications where local codes require service disconnects to be located outside the dwelling. The meter socket supports a standard utility meter and a main disconnect breaker which provides a time and space saving solution for contractors and installers. Meter mains are surface mount with provisions. This is for the field installation of the service disconnect(s) that feed devices downstream. Interior subfeed load centers are typically used with these. This CSED is a Homeline ringless type with horn bypass, and combination overhead/underground feed. With a current rating of 400A, this product has a short circuit current rating of 22kA. Single main service disconnects option is also available. Devices meet the Electric Utility Service Equipment Requirements Committee (EUSERC) standards, Federal Specifications W-P-115C for government housing.
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1407020EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : N/A
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Height : 32.68 in
    • Tightening Torque : main lugs 500 lb.in, aluminium/copper || main lugs 500 lb.in, AWG 4/0...600 kcmil, aluminium/copper || service ground 50 lb.in, AWG 14...AWG 1/0, copper || service ground 50 lb.in, AWG 12...AWG 1/0, aluminium || branch lugs 50 lb.in, AWG 3...AWG 2/0, aluminium/copper || branch lugs 45 lb.in, AWG 6...AWG 4, aluminium/copper || branch lugs 40 lb.in, AWG 8, aluminium/copper || branch lugs 35 lb.in, AWG 14...AWG 10, copper || branch lugs 35 lb.in, AWG 12...AWG 10, aluminium || Cover 10 lb.in
    • Branch Circuit Breaker Rated Current : 30 A || 50 A || 200 A
    • Bypass Type : class 320 lever bypass
    • Service Feed Location : OH || UG
    • Bus Rated Current : 200.0 A
    • Electrical Connection : feed-thru lugs
    • Number Of Circuits : 16
    • Number Of Spaces : 8
    • Number Of Tandem Circuit Breakers : 8
    • Meter Socket Type : ringless
    • Service Disconnect Rated Current : 200 A
    • Line Rated Current : 400 A
    • Awg Gauge : AWG 4...600 kcmil aluminium/copper) || AWG 1/0...350 kcmil 2 aluminium/copper)
    • Width : 28 in
    • Depth : 7.89 in
    • Network Number Of Phases : 1
    • Device Composition : service disconnect (factory installed)
    • Device Mounting : surface
  • Specifications
    • Range Of Product : Homeline
    • Product Or Component Type : Meter Mains
  • Environment
    • Product Certifications : UL E-6294
    • Nema Degree Of Protection : NEMA 3R