Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, lugs, Micrologic 5.0A, 100%

MOLDED CASE CIRCUIT BREAKER 60

SQDPJL36040CU43A PJL36040CU43A 785901952770
24620.25 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, NOM, UL
  • Depth: 8.05 in
  • Height: 12.86 in
  • Line Rated Current: 400-400 A
  • Mounting Type: Unit Mount Lug)
  • Net Weight: 32 lb
  • Standard: CSA, IEC 60947-2, NEMA, NOM-003-SCFI-2000, UL
  • Storage Temperature: -50-85 °C
  • Strip Length: 25 mm
  • Warranty Length: 18 mth
  • Width: 8.27 in
This PowerPact P, circuit breaker has a rated currrent of 400A and a rated operational current of 600VAC with a breaking capacity of 25 kA@600VAC. This unit mounted breaker is a 3-pole and has a continuous current rating of 100 %. This breaker has an electronic trip unit technology and a Micrologic 5.0 A trip unit. Dimensions for this product are 12.86 in (H), 8.05 in (W), 8.27 in (D). This product comes with an 18 month warranty.
QTY
  • Product Description
  • Specifications
This PowerPact P, circuit breaker has a rated currrent of 400A and a rated operational current of 600VAC with a breaking capacity of 25 kA@600VAC. This unit mounted breaker is a 3-pole and has a continuous current rating of 100 %. This breaker has an electronic trip unit technology and a Micrologic 5.0 A trip unit. Dimensions for this product are 12.86 in (H), 8.05 in (W), 8.27 in (D). This product comes with an 18 month warranty.
  • Specifications
    • Product Or Component Type : circuit breaker
    • Product Name : PowerPact P
    • Device Application : distribution
    • Range : PowerPact
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Mounting Mode : unit mount lug)
    • Network Frequency : 50/60 Hz
    • Wire Stripping Length : 25 mm
    • Terminal Identifier : AL800M23K
    • Line Rated Current : 400-400 A
    • [Ics] Rated Service Breaking Capacity : 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • Long Time Pick-Up Adjustment Range : 0.4...1 x Ir
    • Trip Unit Technology : electronic, ammeter, Micrologic 5.0 A, LSI
    • Trip Unit Name : Micrologic 5.0 A
    • Height : 12.86 in
    • Continuous Current Rating : 100 %
    • Breaking Capacity : AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • [Ui] Rated Insulation Voltage : 750 V IEC 60947-2
    • [Ue] Rated Operational Voltage : 600 V AC 50/60 Hz UL 489
    • Tightening Torque : 50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil) || 1.0-1.3 N.m
    • Mounting Support : lug
    • Breaking Capacity Code : J
    • Poles Description : 3P
    • Local Signalling : overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
    • Quantity Per Set : 1
    • Number Of Slots : 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
    • Awg Gauge : 3 x AWG 3/0...3 x 500 kcmil aluminium/copper
    • Width : 8.27 in
    • Electrical Connection : lugs line || lugs load
    • Depth : 8.05 in
    • Net Weight : 32 lb(US)
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • Control Type : toggle
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : ENVEOLI1407012EN
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1407012EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Eu Rohs Directive : Compliant
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Ambient Air Temperature For Operation : -2-70 °C
    • Pollution Degree : 3 IEC 60947-1
    • Ambient Air Temperature For Storage : -50-85 °C
    • Standards : UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
    • Quality Labels : CE
    • Product Certifications : UL || CSA || NOM
    • Operating Altitude : < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
    • Ip Degree Of Protection : front cover IP40