SQUARE D

Circuit Breaker, PowerLink™, 15A, 1 pole, 277VAC, 14kA, remotely operated, bolt on mount [TAA]

MOLDED CASE CIRCUIT BREAKER 48

SQDECB14015G3 ECB14015G3 785901335849
322.10 / EACH
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
PowerLink™ circuit breakers are one-pole, two-pole, and three-pole thermal-magnetic circuit breakers that provide arc fault circuit interrupters for PowerLink™ Intelligent panelboard. They can be configured to automatically or manually reset once tripped using a bimetallic strip. This circuit breaker is HACR rated to a current capacity of 15 amperages, allowing for it be ideally used in congruence with HVAC systems. Certified by the Underwriters Laboratory to meet the designed specifications.
QTY
  • Product Description
  • Features
  • Specifications
PowerLink™ circuit breakers are one-pole, two-pole, and three-pole thermal-magnetic circuit breakers that provide arc fault circuit interrupters for PowerLink™ Intelligent panelboard. They can be configured to automatically or manually reset once tripped using a bimetallic strip. This circuit breaker is HACR rated to a current capacity of 15 amperages, allowing for it be ideally used in congruence with HVAC systems. Certified by the Underwriters Laboratory to meet the designed specifications.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL Listed, CSA
  • Complementary Attributes
    • Line Rated Current : 15 A
    • Ue Rated Operational Voltage : 480Y/277 V AC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer
    • Awg Gauge : AWG 10...AWG 8 aluminium, AWG 12...AWG 8 copper
    • Circuit Breaker Application : HACR rated, HID rated, Switching Duty rated
    • Carbon Footprint Of The Distribution Phase A4 : 0.2115974889, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.1 kg CO2 eq., 0.0927297565
    • Carbon Footprint Of The Installation Phase A5 : 0.0166315349, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 4 kg CO2 eq., 3.5618701978
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 51 kg CO2 eq., 50.548
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-18
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • H And D Domain : Safety
    • H And D Subrange : COM
    • H And D Enrichment Assignment : yes
    • H And D Enrichment Function : POWERLINK
    • H And D Enrichment Class 3 : Circuit Breakers
    • H And D Enrichment Class 4 : MCB UL 1P
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Use Carbon Footprint : 50.548
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2212008
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • Product Kit Identifier : N
    • Circuit Breaker Type : ECB-G3
    • Electrical Connection : bolted connection
    • Energy Efficiency Optimized : False
    • Mounting Mode : bolt-on
    • Number Of Spaces Required : 1
    • Poles Description : 1P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : circuit breaker
    • Range Of Product : Powerlink
    • Returnability : Yes
    • Software Version : EIME v5.9.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 54 kg CO2 eq.
    • Trip Unit Technology : thermal-magnetic, standard, LI
    • Accessory Separate Part Type : motor for circuit-breaker 24 V DC
    • Warranty In Months : 18
    • Pep Code : ENVPEP2212008EN
    • Database Version : 2022-01
    • Pep Verification Date : 2023-08-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Protect during 20 years the installation against overloads and short-circuits in circuit with assigned voltage 277 VAC and rated current 20 A. This protection is ensured in accordance with the following parameters:& 10- Number of poles 1P& 10- Rated breaking capacity 18 kA, 25 kA max& 10- Tripping curve 515-1
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 625.958
    • Reference Lifetime In Y2 : 20
    • Energy Model Manufacturing A1 A3 2 : Energy model used: Mexico
    • Energy Model Installation A5 2 : Electricity mix; AC; consumption mix, at consumer; 120V; US
    • Energy Model Use B6 2 : Electricity mix; AC; consumption mix, at consumer; 120V; US
    • Energy Model End Of Life C1 C4 2 : Electricity mix; AC; consumption mix, at consumer; 120V; US
    • Offer Owner Code : 190788
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 2 : 615.44
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 2 : 1.3515
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 2 : 7.7289
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 639.64
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 2 : 680.51
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 40.869
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 639.64
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 2 : 40.869
    • Air Pollution M3 Operational Energy Use B6 2 : 4292.7
    • Water Pollution M3 Operational Energy Use B6 2 : 2492
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 2 : 50.548
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • Carbon Footprint : 54.4308289781
    • Ambient Air Temperature For Operation : 40 °C
    • Circularity Profile : ENVEOLI2212008
    • Environmental Disclosure : ENVPEP2212008EN
    • Eu Rohs Directive : Under investigation
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2212008EN
    • Pep Verification Date : 2023-08-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : circuit breaker
    • Range Of Product : Powerlink
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Compliance : TAA Compliant