SQUARE D

Transformer, control disconnect, 3kVA, 1 phase, 240x480V primary, 120V secondary, 115C rise

MELTING ALLOY O/LOADRELAY 600V

SQD9065SEO8S1 9065SEO8S1 785901117506
250.20 / EACH
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Warranty Length: 18 mth
Overload relays are intended to protect motors, controllers, and branch-circuit conductors against excessive heating due to prolonged motor over currents up to and including locked rotor currents. Protection of the motor and the other branch circuit components from higher currents, due to short circuits or grounds, is a function of the branch circuit fuses, circuit breakers, or motor short circuit protectors. The exclusive one piece melting alloy thermal unit is used in these relays to provide protection against overheating of the motor winding insulation due excessive over current. The melting alloy thermal unit to be used is determined by the full load current of the motor to be controlled, number of phases and the enclosure size. This 45A separate mount overload relay can be used with NEMA size 2 three phase starters with 3 poles. When 3 thermal units are properly installed the relay can be reset. Overload relay has a trip free reset mechanism. The output contact is replaceable. Relay has a maximum voltage rating of 600 VAC. This separate mount overload relay is UL Listed and CSA Certified.
QTY
  • Product Description
  • Features
  • Specifications
Overload relays are intended to protect motors, controllers, and branch-circuit conductors against excessive heating due to prolonged motor over currents up to and including locked rotor currents. Protection of the motor and the other branch circuit components from higher currents, due to short circuits or grounds, is a function of the branch circuit fuses, circuit breakers, or motor short circuit protectors. The exclusive one piece melting alloy thermal unit is used in these relays to provide protection against overheating of the motor winding insulation due excessive over current. The melting alloy thermal unit to be used is determined by the full load current of the motor to be controlled, number of phases and the enclosure size. This 45A separate mount overload relay can be used with NEMA size 2 three phase starters with 3 poles. When 3 thermal units are properly installed the relay can be reset. Overload relay has a trip free reset mechanism. The output contact is replaceable. Relay has a maximum voltage rating of 600 VAC. This separate mount overload relay is UL Listed and CSA Certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Carbon Footprint Of The Distribution Phase A4 : 0.4266460761906587, 0.4 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.8 kg CO2 eq., 0.8341418140460544
    • Carbon Footprint Of The Installation Phase A5 : 0.26935718172346645, 0.3 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 7 kg CO2 eq., 7.147191530932971
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 5 kg CO2 eq., 5.069037029711683
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1312002EN
    • Rohs Eur In Scope : Yes
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Energy Efficiency Optimized : False
    • Number Of Thermal Units Required : 3
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Returnability : No
    • Software Version : v6.2.5-6
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 14 kg CO2 eq.
    • Warranty In Months : 18
    • Pep Code : ENVPEP1312002EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-09-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - Installation [A5] : No energy used
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model - End Of Life [C1-c4] : Global, European and French datasets are used.
    • Recyclability Potential, In % : 42
    • Offer Owner Code : 190788
    • Pn : 1
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Carbon Footprint : 13.746373632604834
    • Circularity Profile : ENVEOLI1312002EN
    • Environmental Disclosure : ENVPEP1312002EN
    • Eu Rohs Directive : Not compliant
    • Nema Size : 2
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Pep Code : ENVPEP1312002EN
    • Pep Verification Date : 2025-09-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Mexico