SQUARE D

Load center, Homeline, 1 phase, 20 spaces, 40 circuits, 125A convertible main lugs, PoN, NEMA1, combo cover

HOM INDR 125A MLO 20/40CIR

SQDHOM2040L125PC HOM2040L125PC 785901860693
78.89 / EACH
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Cover Type: Combination Flush/surface Cover
  • Number of Spaces: 20
The Homeline load center offer features Homeline circuit breakers, ground fault circuit breakers and arc fault interrupters. Homeline load centers enable the use of a full complement of accessories. Systems are single phase and are rated for indoor use o
QTY
  • Product Description
  • Features
  • Specifications
The Homeline load center offer features Homeline circuit breakers, ground fault circuit breakers and arc fault interrupters. Homeline load centers enable the use of a full complement of accessories. Systems are single phase and are rated for indoor use o
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0.0431555628
    • 0 kg CO2 eq.
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 1 kg CO2 eq.
    • 0.996327995
  • Phase
    • 1 phase 3 wires
  • Material
    • tin plated aluminium: busbar
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 53 kg CO2 eq.
    • 53.3466433479
  • Nema Degree Of Protection
    • NEMA 1 indoor enclosure
  • Persona Type Names
    • End User
    • Consumer
    • Contractor
    • Original Equipment Manufacturer
    • Electrician
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 0.1 kg CO2 eq.
    • 0.087341
  • Persona Type Ids
    • EU
    • EUA
    • LC
    • OM
    • SC
  • Carbon Footprint Of The Distribution Phase A4
    • 1.3758624859
    • 1 kg CO2 eq.
  • AWG Gauge
    • AWG 6...AWG 2/0 aluminium
    • AWG 6...AWG 1 copper
    • AWG 6...AWG 1/0 copper
  • UE Rated Operational Voltage
    • 120/240 V AC
  • Surface Finish
    • baked enamel Gray
  • Complementary Attributes
    • Bus Rated Current : 125.0 A
  • Important Information Attributes
    • B2B Bullet Point 1 : Fast installation, reliability, and superior circuit protection
    • B2B Bullet Point 2 : Protects against equipment overloads and short-circuits
    • B2B Bullet Point 3 : Tin and copper plated aluminum bus bars
    • B2B Bullet Point 4 : Replacement covers in gray and white
    • B2B Bullet Point 5 : Distributed neutral bars keeps wiring tidy
    • Local Data Status : Publishable
    • Local Publishable Date : 8/18/2025
    • HTML Description : Homeline, LC, 125 A, 120/240 V, 1 PH, MLO, PoN, 20 SP, N1, combo
    • Manufacturer : Schneider Electric
    • Manufacturing Carbon Footprint : 53.34664335
    • Distribution Carbon Footprint : 1.375862486
    • Installation Carbon Footprint : 0.043155563
    • Use Carbon Footprint : 0.087341
    • End Of Life Carbon Footprint : 0.996327995
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Conformity Date : 2531
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • China ROHS Label : 1
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : RESIDENTIAL
    • Market Segmentation : Residential
    • H And D Domain : Safety
    • H And D Subrange : RESI
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : ENCLOSURES
    • H And D Enrichment Class 3 : Load centers (equipped)
    • H And D Enrichment Class 4 : Single-phase convertible mains indoor load center
    • Cover Type : combination flush/surface cover
    • Electrical Connection : lugs
    • Load Center Type : PoN Convertible Mains (lugs)
    • Number Of Spaces : 20
    • Number Of Tandem Circuit Breakers : 20
    • Package Weight Lbs : 10.664 kg
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : Load Center
    • Range Of Product : Homeline
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 56 kg CO2 eq.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 55.84933039
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2212003EN
    • Pep Verification Date : 11/1/2021
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 10664
    • Functional Unit Description : Protect persons during 20 years against direct contact with live parts and allow grouping monitoring, control and protection devices in a single enclosure or a cabinet having the following dimensions 1000mm x362mm x 95mm, that is certified for UL 67.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 0.126144
    • Energy Model Manufacturing A1 A3 : Energy model used: Tlaxcala Mexico
    • Energy Model Installation A5 : Electricity mix; AC; 120V; US
    • Energy Model Use B6 : Electricity mix; AC; 120V; US
    • Energy Model End Of Life C1 C4 : Electricity mix; AC; 120V; US
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.012136132
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.012136045
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 5.51E-08
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 1.6E-09
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 9E-10
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 2.95E-08
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 550.0877969
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 517.5603548
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 19.33041499
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.557758506
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 1.0634
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 11.57586858
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.002482447
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.000233349
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.002249098
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 968.7258281
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 957.6951405
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 4.5826E-06
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.0023352
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 11.02834778
    • Materials For Energy Recovery Kg Total Life Cycle : 0.023151071
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0.023151071
    • Materials For Recycling Kg Total Life Cycle : 10.74253127
    • Materials For Recycling Kg Manufacturing A1 A3 : 1.060471855
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.783181212
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 8.898878201
    • Net Use Of Fresh Water M3 Total Life Cycle : 3.814634856
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 3.813195953
    • Net Use Of Fresh Water M3 Distribution A4 : 0.000123139
    • Net Use Of Fresh Water M3 Installation A5 : 5.1494E-06
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.00015436
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.001156255
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 66.74607993
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 66.62835228
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.048885215
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.01101769
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.013355
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.044469746
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 6.5988E-06
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 6.5343E-06
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 2.8E-09
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 1E-10
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 1.6E-09
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 6.01E-08
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.025090655
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0249848
    • Radioactive Waste Disposed Of Kg Distribution A4 : 3.48175E-05
    • Radioactive Waste Disposed Of Kg Installation A5 : 1.3166E-06
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 1.3741E-06
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 6.83468E-05
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 1049.283768
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 1013.779388
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 19.42832929
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.561461931
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 1.1052
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 14.40938863
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 1069.780177
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 1034.161549
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 19.45430656
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.562481039
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 1.1758
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 14.42604072
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 20.46458528
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 20.35085522
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.025925976
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.001018242
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0.070616
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.016169848
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 16.89254866
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 16.89254866
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 1032.43185
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 996.9274703
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 19.42832929
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.561461931
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 1.1052
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 14.40938863
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 15.58302811
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 15.58302811
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 4.881690391
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 4.767960325
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.025925976
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.001018242
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0.070616
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.016169848
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.21916818
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.21916818
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 17646.44692
    • Air Pollution M3 Manufacturing A1 A3 : 17476.70406
    • Air Pollution M3 Distribution A4 : 58.5294406
    • Air Pollution M3 Installation A5 : 1.765521449
    • Air Pollution M3 Operational Energy Use B6 : 7.4172
    • Air Pollution M3 End Of Life C1 C4 : 102.0307008
    • Water Pollution M3 Total Life Cycle : 2853.002534
    • Water Pollution M3 Manufacturing A1 A3 : 2505.340612
    • Water Pollution M3 Distribution A4 : 226.2619713
    • Water Pollution M3 Installation A5 : 6.524156602
    • Water Pollution M3 Operational Energy Use B6 : 4.3059
    • Water Pollution M3 End Of Life C1 C4 : 110.5698938
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 0.217899988
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.018527815
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.02639224
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 0.208484197
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.006282168
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.000179643
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 0.000083625
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.002870355
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 55.84933039
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 53.34664335
    • Global Warming Kg Equivalent Co2 Distribution A4 : 1.375862486
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.043155563
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 0.087341
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.996327995
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.017743138
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.000448301
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 1.34322E-05
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.000013395
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.000309549
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.02418883
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.001446934
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 4.55754E-05
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.000022038
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.000688864
    • Warranty In Months : 18
  • General Attributes
    • Product Or Component Type : Load Center
    • Range Of Product : Homeline
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=423253467&lang=en-us
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0%
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 55.84933039
    • Environmental Disclosure : ENVPEP2212003EN
    • EU ROHS Directive : Compliant
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2212003EN
    • Pep Verification Date : 11/1/2021
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • Specifications
    • Country of Origin : Mexico