Line-Voltage Fan Coil Room Controller: BACnet MS/TP, RH sensor & control, Silver Case/Fascia [TAA]

LINE-VOLTAGE FAN COIL ROOM CON

SQDSER8350A0B00 SER8350A0B00 3606480771491
398.11 / EA
http://schema.org/OutOfStock
  • Input Voltage: ...10 V
  • Output Voltage: ...10 V, 24 V
This SER8350 Line Voltage fan coil unit room controller works with VC3000 relay pack. With touch color screen. Silver Fascia & Casing. BACnet communication to connect with BMS.
QTY
  • Product Description
  • Features
  • Specifications
This SER8350 Line Voltage fan coil unit room controller works with VC3000 relay pack. With touch color screen. Silver Fascia & Casing. BACnet communication to connect with BMS.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: LEAD, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : EN/IEC 60730-1, FCC part 15 Subpart B, ICES-003, ETSI EN 300 328, ETSI EN 301 489-1:v1.9.2, FCC part 15 Subpart C, UL 60730-2-9, ETSI EN 301 489-17:v2.2.1, 2012
  • Important Information Attributes
    • Sensor Type : 10 kOhm T2 NTC thermistor Temperature, space RH sensor Humidity, bulk polymer Humidity
    • Temperature Setting Range : 12-37.5 °C cooling, 4.5-32 °C heating
    • Carbon Footprint Of The Distribution Phase A4 : 0.3900762008763621, 0.4 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.4 kg CO2 eq., 0.3882996644250015
    • Carbon Footprint Of The Installation Phase A5 : 0.00915778220350734, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 12 kg CO2 eq., 11.79340434044568
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 159 kg CO2 eq., 158.71402126211765
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-09-16
    • HTML Description : Requires SC3000 relay pack to control fan coil unitProduct Alert: Must purchase communication module (VCM8000V5045P) separately for Zigbee Pro
    • Manufacturer : Schneider Electric
    • Device Type : HVAC control devices - HVAC room controller
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DBIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2405011
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Device Short Name : SER8300
    • Economizer : Yes
    • Energy Efficiency Optimized : False
    • Humidity Control : Yes
    • Package Weight Lbs : 220 g
    • PIR Cover : No
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : room controller
    • Range : SpaceLogic
    • Returnability : Yes
    • Scheduling : No
    • Surface Treatment : untreated
    • Sustainable Packaging : No
    • Temperature Resolution : 0.1 °C
    • Total Lifecycle Carbon Footprint : 171 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2405011EN
    • Pep Verification Date : 2024-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
    • Functional Unit Unit : Unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Directives : 2014/30/EU - electromagnetic compatibility, 2014/35/EU - low voltage directive, 2014/53/EU - radio equipment directive
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 171.29495925006822
    • Circularity Profile : ENVEOLI2405011
    • Environmental Disclosure : ENVPEP2405011EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 0-95 %
    • Pep Code : ENVPEP2405011EN
    • Pep Verification Date : 2024-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : room controller
  • Output Attributes
    • Output Type : 5 xrelay output, 4 xuniversal
    • Output Voltage : 24 V AC relay output, 0...10 V DC analog output
    • Output Current : 1 A relay output
  • Input Attributes
    • Input Type : dry contact 2, analog 5
    • Input Voltage : 0...10 V DC
  • Specifications
    • Compliance : TAA