SQUARE D

Limit switch, Limit switches XC Standard, XCKP, plastic roller lever Ø 50 var.length, 1NC+1 NO, snap, M12

LIMIT SWITCH, LIMIT SWITCHES X

SQDXCKP2149M12 T3389110204179
142.66 / EA
http://schema.org/OutOfStock
  • Certifications: CCC, CSA, UL
  • Depth: 30 mm
  • Height: 65-65 mm
  • Material: Plastic
  • Net Weight: 0.16 kg
  • Number of Poles: 2
  • Standard: CSA C22.2 No 14, EN 60204-1, EN 60947-5-1, IEC 60204-1, IEC 60947-5-1, UL 508
  • Storage Temperature: -40-70 °C
  • Warranty Length: 18 mth
  • Width: 31 mm
This product is a compact limit switch with a M12 connector. It features a plastic fixed body and a rotary head, with a variable length thermoplastic roller lever, diameter 50mm. Contacts: 2-pole NC + NO, snap action.
QTY
  • Product Description
  • Specifications
This product is a compact limit switch with a M12 connector. It features a plastic fixed body and a rotary head, with a variable length thermoplastic roller lever, diameter 50mm. Contacts: 2-pole NC + NO, snap action.
  • Specifications
    • Movement Of Operating Head : rotary
    • Range Of Product : Telemecanique Limit switches XC Standard
    • Fixing Mode : by the body
    • Type Of Operator : spring return roller lever thermoplastic variable length, roller diameter 50 mm
    • Sensor Design : compact
    • Product Or Component Type : limit switch
    • Head Material : zamak
    • Material : plastic
    • Head Type : rotary head
    • Type Of Approach : lateral approach, 2 directions
    • Series Name : standard format
    • Contacts Type And Composition : 1 NC + 1 NO
    • Body Type : fixed
    • Contact Operation : snap action
    • Body Material : plastic
    • Device Short Name : XCKP
    • Number Of Poles : 2
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Height : 65-65 mm
    • Terminals Description Iso N°1 : (21-22)NC || (13-14)NO
    • Short-Circuit Protection : 4 A cartridge fuse gG
    • Electrical Connection : male connector M12, 4 pins
    • [Ithe] Conventional Enclosed Thermal Current : 3 A
    • Net Weight : 0.16 kg
    • [Uimp] Rated Impulse Withstand Voltage : 2.5 kV IEC 60664 || 2.5 kV IEC 60947-1
    • Switch Actuation : by 30° cam
    • [Ui] Rated Insulation Voltage : 300 VUL 508 || 300 VCSA C22.2 No 14 || 250 V 3)IEC 60947-1
    • Electrical Durability : 5000000 cycles, DC-13, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
    • Positive Opening : with
    • Contacts Insulation Form : Zb
    • [Ie] Rated Operational Current : 3 A 240 V, AC-15 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13 EN/IEC 60947-5-1 appendix A
    • Mechanical Durability : 10000000 cycles
    • Maximum Actuation Speed : 1.5 m/s
    • Width : 31 mm
    • Depth : 30 mm
    • Minimum Torque For Tripping : 0.1 N.m
    • Repeat Accuracy : 0.1 mm on the tripping points with 1 million operating cycles
    • Maximum Resistance Across Terminals : 25 MOhm IEC 60255-7 category 3
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110606EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : ENVEOLI110603EN
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Product Certifications : CSA || UL || CCC
    • Ik Degree Of Protection : IK04 EN 50102
    • Ambient Air Temperature For Operation : -25-70 °C
    • Standards : CSA C22.2 No 14 || EN 60204-1 || UL 508 || IEC 60204-1 || IEC 60947-5-1 || EN 60947-5-1
    • Shock Resistance : 50 gn 11 ms IEC 60068-2-27
    • Vibration Resistance : 25 gn 10-500 Hz)IEC 60068-2-6
    • Ip Degree Of Protection : IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
    • Ambient Air Temperature For Storage : -40-70 °C
    • Electrical Shock Protection Class : class II IEC 61140 || class II NF C 20-030
    • Protective Treatment : TC