SQUARE D

Limit switch, Limit switches XC Standard, XC1AC, roller lever, 2NC, simultaneous

LIMIT SWITCH, LIMIT SWITCHES X

SQDXC1AC146 XC1AC146 3389110314984
236.03 / EA
http://schema.org/OutOfStock
  • Certifications: CSA
  • Depth: 44 mm
  • Height: 130-130 mm
  • Material: Metal
  • Net Weight: 0.53 kg
  • Number of Poles: 2
  • Number of Steps: 1
  • Standard: CSA C22.2 No 14, EN 60947-5-1, IEC 60337-1, IEC 60947-5-1, VDE 0660-200
  • Warranty Length: 18 mth
  • Width: 77 mm
QTY
  • Specifications
  • Specifications
    • Movement Of Operating Head : linear
    • Range Of Product : OsiSense XC
    • Electrical Connection : screw-clamp terminals 1 x 0.5...1 x 2.5 mm²
    • Number Of Steps : 1
    • Fixing Mode : by the body
    • Type Of Operator : spring return roller lever metal -
    • Cable Entry : 3 entries tapped for Pg 13.5 cable gland 9-12 mm
    • Product Or Component Type : limit switch
    • Material : metal
    • Head Type : plunger head
    • Switch Actuation : by 30° cam
    • Type Of Approach : lateral approach, 2 directions
    • Series Name : special format
    • Contacts Type And Composition : 2 NC
    • Body Type : fixed
    • Positive Opening : without
    • Contact Operation : slow-break, simultaneous
    • Product Specific Application : materials handling
    • Minimum Force For Tripping : 23 N
    • Device Short Name : XC1AC
    • Number Of Poles : 2
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Height : 130-130 mm
    • Terminals Description Iso N°1 : (21-22)NC || (11-12)NC
    • Short-Circuit Protection : 10 A cartridge fuse gG
    • Net Weight : 0.53 kg
    • [Ui] Rated Insulation Voltage : 500 V ACIEC 60947-5-1 || 500 V ACNF C 20-040 || 600 V DCIEC 60947-5-1 || 600 V DCNF C 20-040 || 600 V ACCSA C22.2 No 14 || 600 V DCCSA C22.2 No 14
    • Electrical Durability : 1000000 cycles, AC-15 50/60 Hz, inductive, 110 V, 900 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 3000000 cycles, DC-13, inductive, 110 V, 40 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 3000000 cycles, DC-13, inductive, 230 V, 33 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 3000000 cycles, DC-13, inductive, 48 V, 35 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15 50/60 Hz, inductive, 230 V, 1900 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15 50/60 Hz, inductive, 48 V, 450 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, inductive, 110 V, 100 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, inductive, 230 V, 95 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, inductive, 48 V, 100 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 3000000 cycles, AC-15 50/60 Hz, inductive, 110 V, 350 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 3000000 cycles, AC-15 50/60 Hz, inductive, 230 V, 430 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 3000000 cycles, AC-15 50/60 Hz, inductive, 48 V, 170 VA 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
    • Contacts Insulation Form : Zb
    • Mechanical Durability : 10000000 cycles
    • Maximum Actuation Speed : 0.5 m/s
    • Width : 77 mm
    • Depth : 44 mm
    • [Ithe] Conventional Enclosed Thermal Current : 10 A
    • Maximum Resistance Across Terminals : 8 mOhm
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110614EN
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Product Certifications : CSA
    • Ambient Air Temperature For Operation : -25-70 °C
    • Standards : IEC 60337-1 || CSA C22.2 No 14 || VDE 0660-200 || EN 60947-5-1 || IEC 60947-5-1
    • Shock Resistance : 95 gn 11 ms IEC 60068-2-27
    • Vibration Resistance : 9 gn 10-500 Hz)IEC 60068-2-6
    • Ip Degree Of Protection : IP65 conforming to IEC 60529 || IP65 conforming to NF C 20-010
    • Ambient Air Temperature For Storage : -40-70 °C
    • Operating Position : any position
    • Electrical Shock Protection Class : class I IEC 61140 || class I NF C 20-030
    • Protective Treatment : TC