Illuminated push button, Harmony XB7, red projecting, 22mm, integral LED, push and push to release, 1NO, 24V AC

ILLUMINATED PUSH BUTTON, HARMO

SQDXB7NJ04B1 XB7NJ04B1 3606480470400
59.24 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
This Harmony XB7, illuminated monolithic red push button operates with a latched push to release mechanism, is supplied with 24V AC/DC and uses screw-clamp terminals. It is easily installed into a standard 22mm diameter cut-outs and connected to control circuits with classic screw-clamp connections. It is clearly distinguishable visually at a distance due to clear colors and illuminated head, minimizing errors in machine control and enabling complex machine statuses to be read at a glance. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. It has a double insulated plastic bezel. Its wide range of operating temperatures from -25°C to 70°C allows versatility in usage of product. It provides high brightness for easy identification of function and operation mode, even in brightly lit environments.
QTY
  • Product Description
  • Features
  • Specifications
This Harmony XB7, illuminated monolithic red push button operates with a latched push to release mechanism, is supplied with 24V AC/DC and uses screw-clamp terminals. It is easily installed into a standard 22mm diameter cut-outs and connected to control circuits with classic screw-clamp connections. It is clearly distinguishable visually at a distance due to clear colors and illuminated head, minimizing errors in machine control and enabling complex machine statuses to be read at a glance. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. It has a double insulated plastic bezel. Its wide range of operating temperatures from -25°C to 70°C allows versatility in usage of product. It provides high brightness for easy identification of function and operation mode, even in brightly lit environments.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Physical Attributes
    • Cad Overall Depth : 57.5 mm
    • Cad Overall Height : 29 mm
    • Cad Overall Width : 29 mm
  • Complementary Attributes
    • IE Rated Operational Current : 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1
    • UI Rated Insulation Voltage : 250 V 3)IEC 60947-1, 250 V 3)IEC 60947-1, 250 V 3)IEC 60947-1
    • UIMP Rated Impulse Withstand Voltage : 4 kV IEC 60947-1, 4 kV IEC 60947-1
    • US Rated Supply Voltage : 24 V AC/DC, 24 V AC/DC
  • Environment Attributes Additional
    • Energy Model Manufacturing A1 A3 : Energy model used: France
    • Energy Model Installation A5 : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model Use B6 : Electricity Mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 : Electricity Mix; AC; < 1kV; EU-27
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.0000259355
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.0000259047
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000000001
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000000306
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000001
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 12.7370981706
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 5.7426382979
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 0.0435033191
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.0005187472
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 6.9190407
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 0.0313971064
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.0000000484
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.0000000046
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.0000000439
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 0.4653826034
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.4309174468
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0000001353
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0344650213
    • Materials For Energy Recovery Kg Total Life Cycle : 0.0004435915
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0.0004435915
    • Materials For Recycling Kg Total Life Cycle : 0.0146813821
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.0020157957
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.0001181821
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.0125474043
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.0041006088
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.0023451574
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000002771
    • Net Use Of Fresh Water M3 Installation A5 : 0.0000000274
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.0017519896
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.0000031572
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 2.6457846096
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.1327761702
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0001100221
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0002846604
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 2.51250831
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0001054468
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.000000214
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000000507
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000001632
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000002
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.0021315684
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0000832208
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0000000784
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000000099
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.0020480932
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000001662
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj TLC : 18.3493118209
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 5.6366297872
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.0437249362
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.0004077038
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 12.6341865
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.0343628936
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 19.4720380736
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 5.7852255319
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 0.0437831489
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.0004161906
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 13.6082115
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 0.0344017021
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj TLC : 1.1224329498
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 0.1486059574
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.0000583486
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.0000084872
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 0.97372197
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.0000381866
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.4510876596
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.4510876596
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj TLC : 17.8982139485
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Mfg A1 A3 : 5.1855319149
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Dist A4 : 0.0437249362
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Inst A5 : 0.0004077038
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 12.6341865
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.0343628936
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.0002597106
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.0002597106
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of RE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of RE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj TLC : 1.1221776307
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Mfg A1 A3 : 0.1483506383
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Dist A4 : 0.0000583486
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Inst A5 : 0.0000084872
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj OpEnergy B6 : 0.97372197
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.0000381866
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.0004442043
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.0004442043
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 82.3695297702
    • Air Pollution M3 Manufacturing A1 A3 : 53.178893617
    • Air Pollution M3 Distribution A4 : 0.1317242553
    • Air Pollution M3 Installation A5 : 0.0038645106
    • Air Pollution M3 Operational Energy Use B6 : 28.8068976
    • Air Pollution M3 End Of Life C1 C4 : 0.2481497872
    • Water Pollution M3 Total Life Cycle : 114.6692132872
    • Water Pollution M3 Manufacturing A1 A3 : 85.6759148936
    • Water Pollution M3 Distribution A4 : 0.5092187234
    • Water Pollution M3 Installation A5 : 0.004416817
    • Water Pollution M3 Operational Energy Use B6 : 28.1848203
    • Water Pollution M3 End Of Life C1 C4 : 0.2948425532
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 0.0060601439
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.0003464593
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.0004996845
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 0.0009591626
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.0000141386
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.0000001427
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 0.0050796486
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.0000070515
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 1.187691144
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 0.5093208511
    • Global Warming Kg Equivalent Co2 Distribution A4 : 0.0030965106
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.0000364912
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 0.67168764
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.0035496511
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.0001046196
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.0000010089
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0.000000011
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.000240082
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.0000007378
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.0003039523
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.0000032564
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0.0000001386
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.0001904067
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.0000019303
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electrical Durability : 1000000 cycles, DC-13, 0.3 A 24 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.3 A 24 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.3 A 24 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.3 A 24 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.3 A 24 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.3 A 24 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.3 A 24 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.03 A 230 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.03 A 230 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.03 A 230 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.03 A 230 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.03 A 230 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.03 A 230 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.03 A 230 V 216000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.09 A 240 V 108000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.09 A 240 V 108000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.09 A 240 V 108000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.09 A 240 V 108000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.09 A 240 V 108000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.09 A 240 V 108000 cyc/mn 0.5 IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 0.09 A 240 V 108000 cyc/mn 0.5 IEC 60947-5-1 appendix C
    • Electrical Reliability : λ <= 10exp(-6) 17 V 5 mA IEC 60947-5-4, λ <= 10exp(-6) 17 V 5 mA IEC 60947-5-4, λ <= 10exp(-6) 17 V 5 mA IEC 60947-5-4, λ <= 10exp(-6) 17 V 5 mA IEC 60947-5-4
    • Electrical Shock Protection Class : class II conforming to IEC 61140, class II conforming to IEC 61140
    • Electromagnetic Emission : class B IEC 55011, class B IEC 55011
    • Fixing Center : >= 30 x 40 mm support panel) metal 1-6 mm, >= 30 x 40 mm support panel) metal 1-6 mm, >= 30 x 40 mm support panel) metal 1-6 mm, >= 30 x 40 mm support panel) metal 1-6 mm, >= 30 x 40 mm support panel) plastic 2-6 mm, >= 30 x 40 mm support panel) plastic 2-6 mm, >= 30 x 40 mm support panel) plastic 2-6 mm, >= 30 x 40 mm support panel) plastic 2-6 mm
    • Fixing Mode : fixing nut beneath head 2-2.4 N.m, fixing nut beneath head 2-2.4 N.m
    • Operator Profile : red projecting, unmarked, red projecting, unmarked, red projecting, unmarked
    • Service Life : 70000 h at rated voltage and 25 °C, 70000 h at rated voltage and 25 °C
    • Shape Of Screw Head : cross JIS No 1, cross JIS No 1, cross Philips no 1, cross Philips no 1, cross pozidriv No 1, cross pozidriv No 1, slotted flat Ø 4 mm, slotted flat Ø 4 mm, slotted flat Ø 5.5 mm, slotted flat Ø 5.5 mm
    • Shock Resistance : 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27, 30 gn 18 ms) half sine wave acceleration, 30 gn 18 ms) half sine wave acceleration, 30 gn 18 ms) half sine wave acceleration
    • Short Circuit Protection : 4 A cartridge fuse gG IEC 60947-5-1, 4 A cartridge fuse gG IEC 60947-5-1, 4 A cartridge fuse gG IEC 60947-5-1, 4 A cartridge fuse gG IEC 60947-5-1
    • Supply Voltage Limits : 19.2-30 V DC, 19.2-30 V DC, 21.6-26.4 V AC, 21.6-26.4 V AC
    • Tightening Torque : 0.8-1.2 N.m IEC 60947-1, 0.8-1.2 N.m IEC 60947-1
    • Vibration Resistance : 5 gn (f= 2-500 Hz) conforming to IEC 60068-2-6, 5 gn (f= 2-500 Hz) conforming to IEC 60068-2-6, 5 gn (f= 2-500 Hz) conforming to IEC 60068-2-6
    • IE Rated Operational Current : 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.1 A 250 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.22 A 125 V, DC-13, R300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.3 A 240 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1, 0.6 A 120 V, AC-14, D300 IEC 60947-5-1
    • Connections Terminals : screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1, screw clamp terminals, 1 x 0.34...2 x 2.5 mm² without cable end IEC 60947-1, screw clamp terminals, 1 x 0.34...2 x 2.5 mm² without cable end IEC 60947-1, screw clamp terminals, 1 x 0.34...2 x 2.5 mm² without cable end IEC 60947-1, screw clamp terminals, 1 x 0.34...2 x 2.5 mm² without cable end IEC 60947-1
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-25
    • HTML Description : Illuminated push button, Harmony XB7, red projecting, 22mm, integral LED, push and push to release, 1NO, 24V AC
    • Manufacturer : Square D
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2502022EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Bulb Base : integral LED
    • Compatibility Code : XB7
    • Device Short Name : XB7
    • Mounting Diameter : 22 mm
    • Package Weight Lbs : 24.000 g
    • Positive Opening : with (only NO)
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : illuminated push-button
    • Range Of Product : Harmony XB7
    • Returnability : No
    • Shape Of Signaling Unit Head : round
    • Signalling Type : steady
    • Sustainable Packaging : No
    • Terminals Description ISO N 1 : (13-14)NO
    • Total Lifecycle Carbon Footprint : 1 kg CO2 eq.
    • Type Of Operator : push and push-to-release
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pep Code : ENVPEP2502022EN
    • Pep Verification Date : 2018-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Switch ON/OFF electical contact, and/or provide visual signaling for 20 years at a 30% use rate.
    • Functional Unit Unit : unité (unit)
    • Product Kit Identifier : N
    • Huella De Carbono De La Fase De Distribución A4 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Fabricación A1 A A3 : 0.5 kg CO2 eq.
    • Huella De Carbono De La Fase De Fin De Vida C1 A C4 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Instalación A5 : 0 kg CO2 eq.
    • Huella De Carbono De La Fase De Uso B2 B3 B4 B6 : 0.7 kg CO2 eq.
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • IP Degree Of Protection : IP20 IEC 60529 rear face), IP20 IEC 60529 rear face), IP20 IEC 60529 rear face), IP65 IEC 60529 front face), IP65 IEC 60529 front face), IP65 IEC 60529 front face)
    • Nema Degree Of Protection : NEMA 12 UL 50 E, NEMA 12 UL 50 E
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 1.187691144
    • Circularity Profile : ENVEOLI2502022EN
    • Environmental Disclosure : ENVPEP2502022EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2502022EN
    • Pep Verification Date : 2018-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : illuminated push-button
    • Range Of Product : Harmony XB7
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Overview Attributes
    • Device Presentation : monolithic product