SQUARE D

ION8650 meter 64MB, 9S/29S/36S, 120VAC/160VDC 60Hz, Full comm 3I+4O

ION8650 meter 64MB, 9S/29S/36S

SQDS8650B0C0H6C7B0A S8650B0C0H6C7B0A SQDS8650B0C0H6C7B0A
0.00 / EA
http://schema.org/OutOfStock
  • Depth: 237 mm
  • Height: 178 mm
  • Line Rated Current: 1 A, 2 A, 5 A
  • Mounting Type: Socket-mounted
  • Net Weight: 7 kg
  • Number of Outputs: 2, 4
  • Standard: ANSI C12.1, IEC 62052-11
  • Width: 178 mm
QTY
  • Specifications
  • Specifications
    • Product Or Component Type : energy and power quality meter
    • Product Name : PowerLogic ION8650
    • Device Short Name : ION8650B
    • Range : PowerLogic
  • Complementary
    • Network Frequency : 60 Hz
    • Communication Port Support : RJ11 modem || RJ45 Ethernet || SUB-D 9 RS485/RS232 || infrared || terminal block RS485
    • Power Quality Analysis : harmonic distortion || programmablity (logic and math functions) || voltage sag and swell detection || up to the 63rd harmonic || IEC 61000-4-15 flicker || transient capture || EN 50160 compliance report || IEC 61000-4-30 class S power quality measurement || magnitude harmonic up to the 40th || EN 50160 ed. 4 power quality monitoring
    • Form Designation : 9S 3-element 4 || 36S 2 1/2-element 4 || 29S 2 1/2-element 4
    • Time Synchronisation Protocol : IRIG-B || GPS: Truetime/Datum
    • Measurement Accuracy : current 0.1 % || voltage 0.1 % || power 0.1 % || power factor 0.1 % || frequency 0.001 Hz || energy 0.1 %
    • Measurement Voltage : 57-277 V AC phase to neutral || 100-480 V AC phase to phase
    • Sampling Rate : 1024 samples/cycle
    • Ethernet Service : enable/disable serial ports || SNMP-Traps and SYSLOG || enable/disable Ethernet protocols
    • Memory Capacity : 64 MB
    • Number Of Outputs : 2 pulse || 4 form C relay output
    • Type Of Measurement : power factor total || power factor per phase || apparent power total || apparent power per phase || active power total || active power per phase || reactive power total || reactive power per phase || current || voltage || frequency
    • Poles Description : 1P + N || 3P || 3P + N
    • Communication Port Protocol : TCP/IP 10/100 Mbit/s || DNP3 300...115200 bauds || ION 300...115200 bauds || DLMS 300...115200 bauds || Modbus 57600 bauds || Ansi C12.18 <= 19200 bauds || DNP3 10/100 Mbit/s || ION 10/100 Mbit/s || IEC 61850 ed. 2 10/100 Mbit/s || TCP/IP 300...57600 bauds || Modbus RTU, master/slave 300...115200 bauds || Modbus TCP, master/slave 10/100 Mbit/s || EtherGate || ModemGate
    • Compatibility Code : ION8650B
    • Data Recording : GPS synchronisation || alarms || time stamping || harmonics logs || revenue logs || sag and swell logs || data logs || event logs || historical logs
    • [Us] Rated Supply Voltage : 120...277 V AC 47...63 Hz || 65...120 V AC 47...63 Hz || 80...160 V DC
    • Line Rated Current : 1 A || 5 A || 2 A
    • Outlet Standard : American
    • Analogue Input Type : current 0.01...20 A 0.05 Ohm)
    • Web Services : robust security logs || alarm notification by e-mail || web server || port addressing user designed
    • Display Type : FSTN transflective LCD
    • Transmission Rate : 57600 bauds || 300...115200 bauds || <= 19200 bauds || 300...57600 bauds || 10/100 Mbit/s
    • Power Consumption In Va : 24 VA
    • Number Of Inputs : 3 digital 0.001...100 mA 30 V DC
    • Device Application : load curtailment || energy pulsing and totalisation || equipment monitoring and control || co-generation and IPP monitoring || instrument transformer correction || tariff metering || demand and power factor control
    • Tamperproof Of Settings : protected by access code
    • Accuracy Class : class 0.2S energy IEC 62053-22 || class 0.2S energy IEC 62053-23 || class 0.2 energy ANSI C12.20
    • Measurement Current : 0.001-24 A
    • Maximum Power Consumption In Va : 33 VA
  • Offer Sustainability
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI110703EN
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110723EN
    • Sustainable Offer Status : Green Premium product
    • Eu Rohs Directive : Compliant
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • Environment
    • Ambient Air Temperature For Operation : -40-85 °C
    • Height : 178 mm
    • Pollution Degree : 2
    • Mounting Mode : socket-mounted
    • Ambient Air Temperature For Storage : -40-85 °C
    • Relative Humidity : 5-95 %
    • Mounting Support : enclosure door
    • Standards : ANSI C12.1 || IEC 62052-11
    • Ip Degree Of Protection : front face IP65 || back IP51
    • Electromagnetic Compatibility : electrostatic discharge immunity test IEC 61000-4-2 || susceptibility to electromagnetic fields IEC 61000-4-3 || electrical fast transient/burst immunity test IEC 61000-4-4 || 1.2/50 µs shock waves immunity test IEC 61000-4-5 || conducted and radiated emissionsB CISPR 22 || conducted RF disturbances IEC 61000-4-6 || immunity to impulse waves IEC 61000-4-12
    • Width : 178 mm
    • Overvoltage Category : III
    • Depth : 237 mm
    • Net Weight : 7 kg
    • Type Of Installation : indoor installation
    • Operating Altitude : 0...9842.52 ft (0...3000 m)