SQUARE D

ION8650 meter 128MB, 9S/29S/36S, 277VAC 60Hz, Full comm No I/O

ION8650 meter 128MB, 9S/29S/36

SQDS8650A0C0E6C7A0A SQDS8650A0C0E6C7A0A
0.00 / EA
http://schema.org/OutOfStock
  • Depth: 237 mm
  • Height: 178 mm
  • Line Rated Current: 1 A, 2 A, 5 A
  • Mounting Type: Socket-mounted
  • Net Weight: 7 kg
  • Number of Outputs: 2
  • Standard: ANSI C12.1, IEC 62052-11
  • Width: 178 mm
QTY
  • Specifications
  • Specifications
    • Product Or Component Type : energy and power quality meter
    • Product Name : PowerLogic ION8650
    • Device Short Name : ION8650A
    • Range : PowerLogic
  • Complementary
    • Network Frequency : 60 Hz
    • Communication Port Support : RJ45 Ethernet || SUB-D 9 RS485/RS232 || terminal block RS485 || infrared || RJ11 modem
    • Power Quality Analysis : IEC 61000-4-15 flicker || magnitude harmonic up to the 50th || transient capture || EN 50160 ed. 4 compliance report || harmonic distortion || voltage sag and swell detection || waveform capture || programmablity (logic and math functions) || up to the 63rd harmonic || IEC 61000-4-30 class A power quality measurement
    • Form Designation : 9S 3-element 4 || 36S 2 1/2-element 4 || 29S 2 1/2-element 4
    • Time Synchronisation Protocol : GPS: Truetime/Datum || IRIG-B
    • Measurement Accuracy : current 0.1 % || voltage 0.1 % || power 0.1 % || power factor 0.1 % || frequency 0.001 Hz || energy 0.1 %
    • Measurement Voltage : 57-277 V AC phase to neutral || 100-480 V AC phase to phase
    • Sampling Rate : 1024 samples/cycle
    • Ethernet Service : enable/disable serial ports || enable/disable Ethernet protocols || SNMP-Traps and SYSLOG
    • Memory Capacity : 128 MB
    • Number Of Outputs : 2 pulse
    • Type Of Measurement : current || voltage || frequency || apparent power total || power factor total || apparent power per phase || power factor per phase || active power total || active power per phase || reactive power total || reactive power per phase
    • Communication Port Protocol : DNP3 300...115200 bauds || ION 300...115200 bauds || Ansi C12.18 <= 19200 bauds || IEC 61850 ed. 2 10/100 Mbit/s || TCP/IP 10/100 Mbit/s || DLMS 300...115200 bauds || Modbus 57600 bauds || TCP/IP 300...57600 bauds || DNP3 10/100 Mbit/s || ION 10/100 Mbit/s || ModemGate || Modbus RTU, slave 300...115200 bauds || Modbus TCP, slave 10/100 Mbit/s || EtherGate
    • Poles Description : 3P || 3P + N || 1P + N
    • Compatibility Code : ION8650A
    • Data Recording : GPS synchronisation || harmonics logs || revenue logs || time stamping || historical logs || event logs || alarms || sag and swell logs || transient logs || data logs
    • [Us] Rated Supply Voltage : 120...277 V AC 47...63 Hz || 120...480 V AC 47...63 Hz
    • Line Rated Current : 5 A || 1 A || 2 A
    • Analogue Input Type : current 0.01...20 A 0.05 Ohm)
    • Web Services : web server || robust security logs || port addressing user designed || alarm notification by e-mail
    • Display Type : FSTN transflective LCD
    • Transmission Rate : 10/100 Mbit/s || 300...57600 bauds || <= 19200 bauds || 57600 bauds || 300...115200 bauds
    • Power Consumption In Va : 24 VA
    • Number Of Inputs : 0
    • Device Application : co-generation and IPP monitoring || tariff metering || load curtailment || equipment monitoring and control || instrument transformer correction || demand and power factor control || energy pulsing and totalisation
    • Tamperproof Of Settings : protected by access code
    • Accuracy Class : class 0.2S energy IEC 62053-23 || class 0.2 energy ANSI C12.20 || class 0.2S energy IEC 62053-22
    • Measurement Current : 0.001-24 A
    • Maximum Power Consumption In Va : 33 VA
  • Offer Sustainability
    • China Rohs Regulation : X
    • Circularity Profile : ENVEOLI110703EN
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110723EN
    • Sustainable Offer Status : Green Premium product
    • Eu Rohs Directive : Compliant
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • Environment
    • Ambient Air Temperature For Operation : -40-85 °C
    • Height : 178 mm
    • Pollution Degree : 2
    • Mounting Mode : socket-mounted
    • Ambient Air Temperature For Storage : -40-85 °C
    • Relative Humidity : 5-95 %
    • Mounting Support : enclosure door
    • Standards : ANSI C12.1 || IEC 62052-11
    • Ip Degree Of Protection : front face IP65 || back IP51
    • Electromagnetic Compatibility : electrostatic discharge immunity test IEC 61000-4-2 || conducted RF disturbances IEC 61000-4-6 || immunity to impulse waves IEC 61000-4-12 || electrical fast transient/burst immunity test IEC 61000-4-4 || susceptibility to electromagnetic fields IEC 61000-4-3 || 1.2/50 µs shock waves immunity test IEC 61000-4-5 || conducted and radiated emissionsB CISPR 22
    • Width : 178 mm
    • Overvoltage Category : III
    • Depth : 237 mm
    • Net Weight : 7 kg
    • Type Of Installation : indoor installation
    • Operating Altitude : 0...9842.52 ft (0...3000 m)