SQUARE D

IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 127VAC 50/60Hz coil, open

IEC CONTACTOR, TESYS DECA, NON

SQDLC1D40AFC7 LC1D40AFC7 3389118326613
296.19 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Warranty Length: 18 mth
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 40A/440V AC-3/3e (18.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 127V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contact
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 40A/440V AC-3/3e (18.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 127V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contact
  • Insulation Resistance
    • > 10 MOhm for signalling circuit
  • Heat Dissipation
    • 4-5 W at 50/60 Hz
  • Inrush Power In VA
    • 140-140 VA 60 Hz cos phi 0.75 (at 20 °C)
    • 160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
    • 160-160
  • Connections Terminals
    • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
    • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffne
  • IE Rated Operational Current
    • 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • 60 A (at <60 °C) at <= 440 V AC AC
  • ITH Conventional Free Air Thermal Current
    • 10 A (at 60 °C) for signalling circuit
    • 60 A (at 60 °C) for power circuit
  • CAD
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003731_3D-CAD&p_File_name=MCADPP0003731_3D-simplified.stp
    • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003731_3D-CAD&p_File_name=MCADPP0003731_2D-back.dwg
    • https://downlo
  • IP Degree Of Protection
    • IP20 front face IEC 60529
  • Climatic Withstand
    • IACS E10 exposure to damp heat
    • IEC 60947-1 Annex Q category D exposure to damp heat
  • Power Dissipation Per Pole
    • 2.4 W AC-3
    • 5.4 W AC-1
    • 2.4 W AC-3e
  • Maximum Operating Rate
    • 3600 cyc/h at 60 °C
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0 kg CO2 eq.
    • 0.022837598859720254
  • Non Overlap Time
    • 1.5 ms on de-energisation between NC and NO contact
    • 1.5 ms on energisation between NC and NO contact
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 1.5197069782699568
    • 2 kg CO2 eq.
  • Standards
    • EN 60947-4-1
    • EN 60947-5-1
    • IEC 60947-4-1
    • IEC 60947-5-1
    • CSA C22.2 No 14
    • UL 60947-4-1
    • IEC 60335-2-40:Annex JJ
    • UL 60335-2-40:Annex JJ
    • IEC 60335-1:Clause 30.2
  • Operating Time
    • 4...19 ms opening
    • 12...26 ms closing
  • Control Circuit Type
    • AC 50/60 Hz
  • Minimum Switching Voltage
    • 17 V for signalling circuit
  • UC Control Circuit Voltage
    • 127 V AC 50/60 Hz
  • ICW Rated Short Time Withstand Current
    • 320 A 40 °C - 10 s for power circuit
    • 720 A 40 °C - 1 s for power circuit
    • 720 A 40 °C - 1 s for power circui
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 5 kg CO2 eq.
    • 5.048661309412005
  • Protective Treatment
    • THIEC 60068-2-30
  • UI Rated Insulation Voltage
    • power circuit 600 V CSA
    • power circuit 600 V UL
    • signalling circuit 690 V IEC 60947-1
    • si
  • Average Impedance
    • 1.5 mOhm - Ith 60 A 50 Hz for power circuit
  • Accessories
    • GV3G264
    • LAD9R3
  • Electrical Durability
    • 1.4 Mcycles 60 A AC-1 <= 440 V
    • 1.5 Mcycles 40 A AC-3 <= 440 V
    • 1.5 Mc
  • Maximum Horse Power Rating
    • 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
    • 10 hp at
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • System Integrator
  • Fire Resistance
    • 850 °C IEC 60695-2-1
  • Contactor Application
    • motor control
    • resistive load
  • Motor Power KW
    • 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
    • 11 kW at 220...230 V AC 50/60 Hz (AC-3)
    • 11 k
  • Flame Retardance
    • V1 conforming to UL 94
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 54 kg CO2 eq.
    • 53.57766617965933
  • Persona Type Ids
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SI
  • Auxiliaries
    • LADN22
    • LAD4RC3E
    • LADN11
    • LADN20
    • LAD8N11
    • LADT2
    • LADN40
    • LAD6K10F
  • Safety Reliability Level
    • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
    • B10d = 1369863 cycles contactor with nominal load EN/ISO 13
  • Carbon Footprint Of The Distribution Phase A4
    • 1.0844582125739306
    • 1 kg CO2 eq.
  • Tightening Torque
    • control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
    • control circuit 1.7 N.
  • Mechanical Robustness
    • vibrations contactor open 2 Gn, 5...300 Hz)
    • vibrations contactor closed 4 Gn, 5...300 Hz)
    • vibrations contactor closed 4
  • Minimum Switching Current
    • 5 mA for signalling circuit
  • Control Circuit Voltage Limits
    • 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
    • 0.8...1.1 Uc (-40-60 °C)
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • IRMS Rated Making Capacity
    • 140 A AC for signalling circuit conforming to IEC 60947-5-1
    • 250 A DC for s
  • Associated Fuse Rating
    • 10 A gG for signalling circuit conforming to IEC 60947-5-1
    • 80 A gG at <= 690
  • Hold In Power Consumption In VA
    • 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
    • 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
    • 15-15 VA 50 Hz cos phi 0.3
  • UE Rated Operational Voltage
    • power circuit <= 690 V AC 25...400 Hz
    • power circuit <= 300 V DC
  • Permissible Ambient Air Temperature Around The Device
    • -40-60 °C
    • 60-70 °C with derating
  • Rated Breaking Capacity
    • 800 A at 440 V for power circuit conforming to IEC 60947
  • Range
    • TeSys
    • TeSys Deca
  • UIMP Rated Impulse Withstand Voltage
    • 6 kV IEC 60947
  • Complementary Attributes
    • Maximum Motor Phase Current : 40 A
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Manufacturing Carbon Footprint : 5.04866130941201
    • Distribution Carbon Footprint : 1.08445821257393
    • Installation Carbon Footprint : 2.28375988597203e-02
    • Use Carbon Footprint : 53.5776661796593
    • End Of Life Carbon Footprint : 1.51970697826996
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1503009EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Conformity Date : 1926
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • China ROHS Label : 1
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Return Indicator : N
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Coil Technology : without built-in suppressor module
    • Compatibility Code : LC1D
    • Contact Compatibility : M2
    • Device Short Name : LC1D
    • Package Weight Lbs : 850.0 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 61 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 61.253330278774946
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1503009EN
    • Pep Verification Date : 2025-07-25
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 881
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 595.68
    • Energy Model Manufacturing A1 A3 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model Installation A5 : No energy used
    • Energy Model Use B6 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model End Of Life C1 C4 : Global, European and French datasets are used.
    • Recyclability Potential In : 62
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 0.3105012333902616
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.05064188912049537
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.004461528549918333
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.00006922043639011143
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 0.2506538366511604
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.004674758632297307
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.023690302264784305
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Biogenic Carbon Content Of The Product Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Product Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Product Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 2.953641077604496
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : -0.05038478000910273
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.001140383935486103
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 2.996074380838786
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.0068110928393263015
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : 0.005442616508310966
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 58.29968488951232
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 5.099042040367205
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 1.0844582125739306
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.02169721492423415
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 50.58159179882055
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 1.5128956228264059
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -1.8215211932958417
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 61.253330278774946
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 5.048661309412005
    • Climate Change Total Kg Co2 Eq Distribution A4 : 1.0844582125739306
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.022837598859720254
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 53.57766617965933
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 1.5197069782699568
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -1.8160785767875305
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.007581427396593733
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.007521042937237615
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.00000000009293552748
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.00000000058312509573
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.00006032367027304114
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.00000006011302245285
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Benefits Loads Beyond System Boundaries D : -0.000653118659420281
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 7156.0398885741115
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 99.92803743350973
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 13.452662505896539
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.2363855877571504
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 7029.970494244105
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 12.452308802843353
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -41.40788236590065
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 2613.9130090279864
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 2517.064972572676
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 8.799500641279622
    • Ecotoxicity Fresh Water Ctue Installation A5 : 0.32016215566932543
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 81.36135449185728
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 6.367019166503893
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -8.505254523112614
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.00000954347205997118
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.0000012885824594312
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.00000001228381546473
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0.00000000041718511134
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.0000082105333845566
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.0000000316552154073
    • Emission Of Fine Particles Incidence Of Diseases Benefits Loads Beyond System Boundaries D : -0.0000009756240772976
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.005672578815105376
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.00015546491788875677
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.0003932600388135305
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0.0051238538584030885
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.0017318352513382596
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.0000514888679597573
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.00000012660013524912
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.00000042283180424082
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.0016774211753776151
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.00000237577606139726
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.00000312817181225655
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 76.1573997426709
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 76.14854498942685
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0.000895763075720031
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0005985585940523933
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.007360431574281222
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -51.32112531524074
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.00000715253810237682
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000714082822656307
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0.00000000001592417431
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0.00000000270859611886
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000000889161567352
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000009373984706
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000587085955757732
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.00000074293816237085
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000050120009545838
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0.00000000192140769615
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0.0000000000684505683
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000023422746547253
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000552074317549
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000027102977336876
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 2.599638221296189
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 0.013267361426106544
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0
    • Impacts Related To Land Use Soil Quality Installation A5 : 0.00006571209436009505
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 2.5756772770505227
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.010627870725199676
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 916.1403173550622
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 0.9124709821635637
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.002397089449160378
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.003669064069984553
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 915.0644916712432
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 0.15728854813614646
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Benefits Loads Beyond System Boundaries D : -0.5576840951883506
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.042361812808039356
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.004809342167463506
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.0020301395219427506
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.00002978415344773737
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.03454465554950482
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.0009478914156805445
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0011829911159244894
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 0.5322067040866347
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.014214806076867257
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.5179918980097675
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.28409138569487474
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.04781453946532673
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0012771274647347028
    • Net Use Of Fresh Water M3 Installation A5 : 0.00004076471597569829
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.22992303096161693
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.005035923087220684
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.03226415702003385
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 13.279381194937764
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 2.245676196799846
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.001100431856214943
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.007950212184255187
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 10.099791129460296
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.9248632246371516
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -1.3780294337014816
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.00000217784277208778
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.00000060218805807326
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.00000095409738340281
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.000000000307697069
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.00000059387179758385
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.00000002737783595886
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.00000029908553529928
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 0.1295134067183308
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.018074021622364073
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.007341161965918564
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.00004729709821682473
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 0.1011285083748952
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.0029224176569361635
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.005467709069916061
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.003587130713946018
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0009247172005259294
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.0002149583994564271
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.00000123569148602436
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.002404530645901061
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.00004168877657657627
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.000635139173857713
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 0.662763294407872
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.05261084342452259
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.02202097010439054
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.0002079446632523471
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 0.5770460038920024
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.010877532323704024
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.013695554653858709
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 7.306628361051783
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 7.306628361051783
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 7958.540517173741
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 103.44118382192981
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 13.452750457115533
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.2675876918865365
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 7828.267818806213
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 13.111176396596408
    • Total Use Of Primary Energy During The Life Cycle Mj Benefits Loads Beyond System Boundaries D : -42.32915056350023
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 802.5006285996283
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 3.5131463884201324
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.00008795121899926119
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.031202104129386118
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 798.2973245621067
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.658867593753059
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -0.9212681975995766
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 7.306628361051783
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 7.306628361051783
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 7148.73326021306
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 92.62140907245795
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 13.452662505896539
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.2363855877571504
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 7029.970494244105
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 12.452308802843353
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -41.40788236590065
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.1236360235441263
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.1236360235441263
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -0.33224914832324237
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 802.3769925760841
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 3.3895103648760063
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.00008795121899926119
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.031202104129386118
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 798.2973245621067
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.658867593753059
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : -0.5890190492763342
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.06440128770879511
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.06440128770879511
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
    • Water Use M3 Eq Total Life Cycle : 12.124824601522093
    • Water Use M3 Eq Manufacturing A1 A3 : 2.052538992164143
    • Water Use M3 Eq Distribution A4 : 0.05485262461035549
    • Water Use M3 Eq Installation A5 : 0.0017502993297437875
    • Water Use M3 Eq Maintenance B2 : 0
    • Water Use M3 Eq Repair B3 : 0
    • Water Use M3 Eq Replacement B4 : 0
    • Water Use M3 Eq Operational Energy Use B6 : 9.835778580541982
    • Water Use M3 Eq End Of Life C1 C4 : 0.17990410487586833
    • Water Use M3 Eq Benefits Loads Beyond System Boundaries D : -1.385678495465789
    • Air Pollution M3 Total Life Cycle : 0
    • Air Pollution M3 Manufacturing A1 A3 : 0
    • Air Pollution M3 Distribution A4 : 0
    • Air Pollution M3 Installation A5 : 0
    • Air Pollution M3 Maintenance B2 : 0
    • Air Pollution M3 Repair B3 : 0
    • Air Pollution M3 Replacement B4 : 0
    • Air Pollution M3 Operational Energy Use B6 : 0
    • Air Pollution M3 End Of Life C1 C4 : 0
    • Air Pollution M3 Benefits Loads Beyond System Boundaries D : 0
    • Water Pollution M3 Total Life Cycle : 0
    • Water Pollution M3 Manufacturing A1 A3 : 0
    • Water Pollution M3 Distribution A4 : 0
    • Water Pollution M3 Installation A5 : 0
    • Water Pollution M3 Maintenance B2 : 0
    • Water Pollution M3 Repair B3 : 0
    • Water Pollution M3 Replacement B4 : 0
    • Water Pollution M3 Operational Energy Use B6 : 0
    • Water Pollution M3 End Of Life C1 C4 : 0
    • Water Pollution M3 Benefits Loads Beyond System Boundaries D : 0
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=1472219&lang=en-us
    • Take Back : No
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 61.2533302787749
    • Circularity Profile : ENVEOLI1503009EN
    • Environmental Disclosure : ENVPEP1503009EN
    • EU ROHS Directive : Compliant
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1503009EN
    • Pep Verification Date : 2025-07-25
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : France