SQUARE D

IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 48/130VAC/VDC coil, open style

IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 48/130VAC/VDC coil, open style

SQDLC1DT80A6EHE LC1DT80A6EHE 3606489493547
738.06 / EA
http://schema.org/OutOfStock
  • Depth: 120 mm
  • Warranty Length: 18 mth
TeSys Deca contactor, 4 poles (4NO), for non-inductive load applications up to 80A/690V AC-1. They can be used to create motor starters for almost any type of application. It provides a low consumption 48-130V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (70mm width), DIN-rail mounting or screw fixing. Power contacts have a 80A resistive load rating. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 4 poles (4NO), for non-inductive load applications up to 80A/690V AC-1. They can be used to create motor starters for almost any type of application. It provides a low consumption 48-130V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (70mm width), DIN-rail mounting or screw fixing. Power contacts have a 80A resistive load rating. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Features
    • Ultra low consumption coil for maximized energy efficiency to meet sustainability needs
    • Designed to meet the requirements of industrial and HVAC applications
    • Easier to install and operate with multi-standard screws
    • With IEC60335-1 compliance, improved fire resistance, and dustproof auxiliaries
    • Digital customer experience for technical documents
    • Maintenance guide via EcoStruxureTM Facility Expect
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_3D-simplified.stp, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-back.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-back.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-bottom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-bottom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-front.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-front.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-isometric.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-isometric.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-left.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-left.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-right.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-right.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-top.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=LC1DT60A6BBE_3D-CAD&p_File_name=LC1DT60A6BBE_2D-top.dxf
  • Conformance Attributes
    • Product Certifications : CCC, CSA, EAC, UL, KC, DNV-GL, LROS (Lloyds register of shipping), UKCA
    • Standards : EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC 60335-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, 0.85...1.1 Uc (-40-60 °C):operational AC/DC, 1...1.1 Uc (60-70 °C):operational AC/DC
    • Irms Rated Making Capacity : 1000 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Icw Rated Short Time Withstand Current : 110 A 40 °C - 10 min for power circuit, 260 A 40 °C - 1 min for power circuit, 520 A 40 °C - 10 s for power circuit, 900 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Uc Control Circuit Voltage : 48...130 V, 48...130 V AC 50/60 Hz, 48...130 V DC
    • Ui Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    • Control Circuit Type : AC/DC 50/60 Hz AC/DC electronic
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 1000 A at 440 V for power circuit conforming to IEC 60947
    • Ie Rated Operational Current : 80 A (at <60 °C) at <= 440 V AC-1 for power circuit
    • Ue Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • Uimp Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
    • Mounting Support : plate, rail
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 55...65 ms closing, 20...80 ms opening
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6, power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4
    • Connections Terminals : power circuit: lugs-ring terminals - external diameter: 16.5 mm, control circuit: lugs-ring terminals - external diameter: 8 mm, lugs-ring terminals
    • Icw Rated Short Time Withstand Current : 110 A 40 °C - 10 min for power circuit, 260 A 40 °C - 1 min for power circuit, 520 A 40 °C - 10 s for power circuit, 900 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Ith Conventional Free Air Thermal Current : 80 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.17932721045458624, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 3.3912164793891697, 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.3 kg CO2 eq., 0.2571210943430275
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 9 kg CO2 eq., 9.090284460002836
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 65 kg CO2 eq., 64.96717391304345
    • Medium Desc : IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 48/130VAC/VDC coil, open style
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-02-26
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1607010
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 1.6 mOhm - Ith 80 A 50 Hz for power circuit
    • Coil Technology : built-in bidirectional peak limiting
    • Compatibility Code : LC1D
    • Contactor Application : resistive load
    • Device Short Name : LC1D
    • Electrical Durability : 0.5 Mcycles 80 A AC-1 <= 440 V
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Halogen Free Status : Halogen free plastic parts and cables product
    • Heat Dissipation : 0.9-0.9 W at 50/60 Hz
    • Hold In Power Consumption In Va : 1.8-1.8 VA 50/60 Hz (at 20 °C)
    • Hold In Power Consumption In W : 0.9-0.9 W 20 °C
    • Inrush Power In Va : 25-25 VA 50/60 Hz (at 20 °C)
    • Inrush Power In W : 20-20 W 20 °C)
    • Mechanical Durability : 10 Mcycles
    • Overvoltage Category : III
    • Pole Contact Composition : 4 NO
    • Poles Description : 4P
    • Power Dissipation Per Pole : 10.2 W AC-1
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca Advanced
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 78 kg CO2 eq.
    • Utilisation Category : AC-1
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ie Rated Operational Current : 80 A (at <60 °C) at <= 440 V AC-1 for power circuit
    • Rated Thermal Current Ith : 80 A
    • Control Circuit Voltage : 48...130 V
    • Rated Thermal Current Hv : 80 A
    • Pep Code : ENVPEP1607010EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Production mix; Low voltage; CZ
    • Energy Model Installation A5 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Use B6 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Production mix; Low voltage; FR
    • Height Nominal : 122 mm
    • Width Nominal : 70 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Climatic Withstand : IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C, -40-60 °C, 60-70 °C with derating
    • Take Back : Nej
    • Halogene Performance : Halogen free plastic parts & cables product
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 77.88512315723308
    • Circularity Profile : ENVEOLI1607010
    • Environmental Disclosure : ENVPEP1607010EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1607010EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca Advanced
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 120 mm