IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 24/60VAC/VDC coil, open style

IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 24/60VAC/VDC coil, open style

SQDLC1DT80A6BNE LC1DT80A6BNE 3606489493530
726.88 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 120 mm
  • Height: 122 mm
  • Net Weight: 1.290 kg
  • Warranty Length: 18 mth
  • Weight: 1.290 kg
  • Width: 70 mm
TeSys Deca contactor, 4 poles (4NO), for non-inductive load applications up to 80A/690V AC-1. They can be used to create motor starters for almost any type of application. It provides a low consumption 24-60V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (70mm width), DIN-rail mounting or screw fixing. Power contacts have a 80A resistive load rating. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Specifications
TeSys Deca contactor, 4 poles (4NO), for non-inductive load applications up to 80A/690V AC-1. They can be used to create motor starters for almost any type of application. It provides a low consumption 24-60V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (70mm width), DIN-rail mounting or screw fixing. Power contacts have a 80A resistive load rating. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Environment
    • Product Certifications : CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
    • Net Weight : 1.290 kg
    • Flame Retardance : V1 conforming to UL 94
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Width : 70 mm
    • Depth : 120 mm
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C || 60-70 °C with derating
    • Height : 122 mm
    • Standards : EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
    • Climatic Withstand : IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
    • Fire Resistance : 850 °C IEC 60695-2-1
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Mercury Free : Yes
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Take-Back : No
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 7.881961328924837
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 96 kg CO2 eq.
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 96.46868069485436
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Environmental Disclosure : ENVPEP1607010
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • Packaging Without Single Use Plastic : No
    • Scip Number : 9bb0b51e-73b5-4128-a86b-723dbbccfe86
    • Carbon Footprint Of The Installation Phase [A5] : 0.07715405638504502
    • Circularity Profile : ENVEOLI1607010
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 86.66975411415483
    • Carbon Footprint Of The End-Of-Life Phase [C1 To C4] : 2 kg CO2 eq.
    • Carbon Footprint Of The Distribution Phase [A4] : 0.1 kg CO2 eq.
    • Eu Rohs Directive : Compliant with Exemptions
  • Complementary
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Minimum Switching Current : 5 mA for signalling circuit
    • Power Dissipation Per Pole : 10.2 W AC-1
    • Average Impedance : 1.6 mOhm - Ith 80 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Mounting Support : plate || rail
    • Hold-In Power Consumption In W : 0.7-0.7 W 20 °C
    • Insulation Resistance : > 10 MOhm for signalling circuit
    • Inrush Power In Va : 15-15 VA 50/60 Hz (at 20 °C)
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Pole Contact Composition : 4 NO
    • Connections - Terminals : power circuit: lugs-ring terminals - external diameter: 16.5 mm || control circuit: lugs-ring terminals - external diameter: 8 mm
    • Coil Technology : built-in bidirectional peak limiting
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Inrush Power In W : 16-16 W 20 °C)
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Hold-In Power Consumption In Va : 1-1 VA 50/60 Hz (at 20 °C)
    • Overvoltage Category : III
    • [Ui] Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1
    • Protective Cover : with
    • [Ith] Conventional Free Air Thermal Current : 80 A (at 60 °C) for power circuit || 10 A (at 60 °C) for signalling circuit
    • Control Circuit Voltage Limits : <= 0.1 Uc (-40-70 °C):drop-out AC/DC || 0.85...1.1 Uc (-40-60 °C):operational AC || 0.8...1.1 Uc (-40-60 °C):operational DC || 1...1.1 Uc (60-70 °C):operational AC/DC
    • Control Circuit Type : AC/DC 50/60 Hz AC/DC electronic
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Pollution Degree : 3
    • Rated Breaking Capacity : 1000 A at 440 V for power circuit conforming to IEC 60947
    • Irms Rated Making Capacity : 1000 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Associated Fuse Rating : 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for signalling circuit conforming to IEC 60947-5-1
    • Operating Time : 55...65 ms closing || 20...80 ms opening
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Signalling Circuit Frequency : 25...400 Hz
    • Tightening Torque : control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4 || control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5
    • Electrical Durability : 0.5 Mcycles 80 A AC-1 <= 440 V
    • Mechanical Durability : 6 Mcycles
    • Compatibility Code : LC1D
    • [Icw] Rated Short-Time Withstand Current : 110 A 40 °C - 10 min for power circuit || 260 A 40 °C - 1 min for power circuit || 520 A 40 °C - 10 s for power circuit || 900 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
    • Heat Dissipation : 0.7-0.7 W at 50/60 Hz
  • Specifications
    • Country of Origin : France
    • Width : 70 mm
    • Height : 122 mm
    • Weight : 1.290 kg
    • [Uc] Control Circuit Voltage : 24...60 V AC 50/60 Hz || 24...60 V DC
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • Contactor Application : resistive load
    • Product Or Component Type : contactor
    • Utilisation Category : AC-1
    • [Ie] Rated Operational Current : 80 A (at <60 °C) at <= 440 V AC-1 for power circuit
    • Poles Description : 4P
    • Range Of Product : TeSys Deca Advanced
    • Device Short Name : LC1D