IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 130VAC/VDC coil, open style

IEC CONTACTOR, TESYS DECA GREE

SQDLC1D65A6EHE LC1D65A6EHE 3606489493424
456.28 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 65A/690V AC-3/3e (30kW@400V). They can be used to create motor starters for almost any type of application. It provides a low consumption 48-130V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.21 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 65A/690V AC-3/3e (30kW@400V). They can be used to create motor starters for almost any type of application. It provides a low consumption 48-130V AC/DC coil with electronic control, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.21 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Conformance Attributes
    • Standards : EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC 60335-1
  • Complementary Attributes
    • Control Circuit Type : AC/DC 50/60 Hz AC/DC electronic, AC/DC 50/60 Hz AC/DC electronic, AC/DC 50/60 Hz AC/DC electronic
    • Control Circuit Voltage Limits : <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, <= 0.1 Uc (-40-70 °C):drop-out AC/DC, 0.85...1.1 Uc (-40-60 °C):operational AC/DC, 0.85...1.1 Uc (-40-60 °C):operational AC/DC, 0.85...1.1 Uc (-40-60 °C):operational AC/DC, 0.85...1.1 Uc (-40-60 °C):operational AC/DC, 1...1.1 Uc (60-70 °C):operational AC/DC, 1...1.1 Uc (60-70 °C):operational AC/DC, 1...1.1 Uc (60-70 °C):operational AC/DC, 1...1.1 Uc (60-70 °C):operational AC/DC
    • IRMS Rated Making Capacity : 1000 A at 440 V for power circuit conforming to IEC 60947, 1000 A at 440 V for power circuit conforming to IEC 60947, 1000 A at 440 V for power circuit conforming to IEC 60947, 1000 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Maximum Horse Power Rating : 5 hp at 115 V AC 60 Hz for 1 phase motors, 5 hp at 115 V AC 60 Hz for 1 phase motors, 5 hp at 115 V AC 60 Hz for 1 phase motors, 5 hp at 115 V AC 60 Hz for 1 phase motors, 5 hp at 115 V AC 60 Hz for 1 phase motors, 10 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 230/240 V AC 60 Hz for 1 phase motors, 10 hp at 230/240 V AC 60 Hz for 1 phase motors, 20 hp at 200/208 V AC 60 Hz for 3 phase motors, 20 hp at 200/208 V AC 60 Hz for 3 phase motors, 20 hp at 200/208 V AC 60 Hz for 3 phase motors, 20 hp at 200/208 V AC 60 Hz for 3 phase motors, 20 hp at 200/208 V AC 60 Hz for 3 phase motors, 20 hp at 230/240 V AC 60 Hz for 3 phase motors, 20 hp at 230/240 V AC 60 Hz for 3 phase motors, 20 hp at 230/240 V AC 60 Hz for 3 phase motors, 20 hp at 230/240 V AC 60 Hz for 3 phase motors, 20 hp at 230/240 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 40 hp at 460/480 V AC 60 Hz for 3 phase motors, 50 hp at 575/600 V AC 60 Hz for 3 phase motors, 50 hp at 575/600 V AC 60 Hz for 3 phase motors, 50 hp at 575/600 V AC 60 Hz for 3 phase motors, 50 hp at 575/600 V AC 60 Hz for 3 phase motors, 50 hp at 575/600 V AC 60 Hz for 3 phase motors
    • Maximum Operating Rate : 3600 cyc/h at 60 °C, 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit, 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit, 17 V for signalling circuit
    • Rated Breaking Capacity : 1000 A at 440 V for power circuit conforming to IEC 60947, 1000 A at 440 V for power circuit conforming to IEC 60947, 1000 A at 440 V for power circuit conforming to IEC 60947, 1000 A at 440 V for power circuit conforming to IEC 60947
    • ICW Rated Short Time Withstand Current : 110 A 40 °C - 10 min for power circuit, 110 A 40 °C - 10 min for power circuit, 110 A 40 °C - 10 min for power circuit, 110 A 40 °C - 10 min for power circuit, 260 A 40 °C - 1 min for power circuit, 260 A 40 °C - 1 min for power circuit, 260 A 40 °C - 1 min for power circuit, 260 A 40 °C - 1 min for power circuit, 640 A 40 °C - 10 s for power circuit, 640 A 40 °C - 10 s for power circuit, 640 A 40 °C - 10 s for power circuit, 640 A 40 °C - 10 s for power circuit, 900 A 40 °C - 1 s for power circuit, 900 A 40 °C - 1 s for power circuit, 900 A 40 °C - 1 s for power circuit, 900 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • IE Rated Operational Current : 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit
    • UC Control Circuit Voltage : 48...130 V AC 50/60 Hz, 48...130 V AC 50/60 Hz, 48...130 V AC 50/60 Hz, 48...130 V DC, 48...130 V DC
    • UE Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz
    • UI Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1, power circuit 690 V IEC 60947-4-1, power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1, signalling circuit 690 V IEC 60947-1, signalling circuit 690 V IEC 60947-1
    • UIMP Rated Impulse Withstand Voltage : 6 kV IEC 60947, 6 kV IEC 60947
    • Maximum Motor Phase Current : 65 A
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1
    • Average Impedance : 1.5 mOhm - Ith 80 A 50 Hz for power circuit, 1.5 mOhm - Ith 80 A 50 Hz for power circuit, 1.5 mOhm - Ith 80 A 50 Hz for power circuit, 1.5 mOhm - Ith 80 A 50 Hz for power circuit
    • Contactor Application : motor control, resistive load
    • Electrical Durability : 1.8 Mcycles 57 A AC-3 <= 440 V, 1.8 Mcycles 57 A AC-3 <= 440 V, 1.8 Mcycles 57 A AC-3 <= 440 V, 1.8 Mcycles 57 A AC-3 <= 440 V, 0.5 Mcycles 80 A AC-1 <= 440 V, 0.5 Mcycles 80 A AC-1 <= 440 V, 0.5 Mcycles 80 A AC-1 <= 440 V, 0.5 Mcycles 80 A AC-1 <= 440 V, 1.8 Mcycles 57 A AC-3e <= 440 V, 1.8 Mcycles 57 A AC-3e <= 440 V, 1.8 Mcycles 57 A AC-3e <= 440 V, 1.8 Mcycles 57 A AC-3e <= 440 V
    • Fire Resistance : 850 °C IEC 60695-2-1, 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94, V1 conforming to UL 94
    • Heat Dissipation : 0.9-0.9 W at 50/60 Hz, 0.9-0.9 W at 50/60 Hz
    • Hold In Power Consumption In VA : 1.8-1.8 VA 50/60 Hz (at 20 °C), 1.8-1.8 VA 50/60 Hz (at 20 °C), 1.8-1.8 VA 50/60 Hz (at 20 °C)
    • Hold In Power Consumption In W : 0.9-0.9 W 20 °C, 0.9-0.9 W 20 °C
    • Inrush Power In VA : 25-25 VA 50/60 Hz (at 20 °C), 25-25 VA 50/60 Hz (at 20 °C), 25-25 VA 50/60 Hz (at 20 °C)
    • Inrush Power In W : 20-20 W 20 °C), 20-20 W 20 °C)
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor open 10 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
    • Motor Power KW : 18.5 kW at 220...230 V AC 50 Hz (AC-3), 18.5 kW at 220...230 V AC 50 Hz (AC-3), 18.5 kW at 220...230 V AC 50 Hz (AC-3), 18.5 kW at 220...230 V AC 50 Hz (AC-3), 18.5 kW at 220...230 V AC 50 Hz (AC-3), 30 kW at 380...400 V AC 50 Hz (AC-3), 30 kW at 380...400 V AC 50 Hz (AC-3), 30 kW at 380...400 V AC 50 Hz (AC-3), 30 kW at 380...400 V AC 50 Hz (AC-3), 30 kW at 380...400 V AC 50 Hz (AC-3), 37 kW at 415 V AC 50 Hz (AC-3), 37 kW at 415 V AC 50 Hz (AC-3), 37 kW at 415 V AC 50 Hz (AC-3), 37 kW at 415 V AC 50 Hz (AC-3), 37 kW at 415 V AC 50 Hz (AC-3), 37 kW at 440 V AC 50 Hz (AC-3), 37 kW at 440 V AC 50 Hz (AC-3), 37 kW at 440 V AC 50 Hz (AC-3), 37 kW at 440 V AC 50 Hz (AC-3), 37 kW at 440 V AC 50 Hz (AC-3), 37 kW at 500 V AC 50 Hz (AC-3), 37 kW at 500 V AC 50 Hz (AC-3), 37 kW at 500 V AC 50 Hz (AC-3), 37 kW at 500 V AC 50 Hz (AC-3), 37 kW at 500 V AC 50 Hz (AC-3), 37 kW at 660...690 V AC 50 Hz (AC-3), 37 kW at 660...690 V AC 50 Hz (AC-3), 37 kW at 660...690 V AC 50 Hz (AC-3), 37 kW at 660...690 V AC 50 Hz (AC-3), 37 kW at 660...690 V AC 50 Hz (AC-3), 18.5 kW at 220...230 V AC 50 Hz (AC-3e), 18.5 kW at 220...230 V AC 50 Hz (AC-3e), 18.5 kW at 220...230 V AC 50 Hz (AC-3e), 18.5 kW at 220...230 V AC 50 Hz (AC-3e), 18.5 kW at 220...230 V AC 50 Hz (AC-3e), 30 kW at 380...400 V AC 50 Hz (AC-3e), 30 kW at 380...400 V AC 50 Hz (AC-3e), 30 kW at 380...400 V AC 50 Hz (AC-3e), 30 kW at 380...400 V AC 50 Hz (AC-3e), 30 kW at 380...400 V AC 50 Hz (AC-3e), 37 kW at 415 V AC 50 Hz (AC-3e), 37 kW at 415 V AC 50 Hz (AC-3e), 37 kW at 415 V AC 50 Hz (AC-3e), 37 kW at 415 V AC 50 Hz (AC-3e), 37 kW at 415 V AC 50 Hz (AC-3e), 37 kW at 440 V AC 50 Hz (AC-3e), 37 kW at 440 V AC 50 Hz (AC-3e), 37 kW at 440 V AC 50 Hz (AC-3e), 37 kW at 440 V AC 50 Hz (AC-3e), 37 kW at 440 V AC 50 Hz (AC-3e), 37 kW at 500 V AC 50 Hz (AC-3e), 37 kW at 500 V AC 50 Hz (AC-3e), 37 kW at 500 V AC 50 Hz (AC-3e), 37 kW at 500 V AC 50 Hz (AC-3e), 37 kW at 500 V AC 50 Hz (AC-3e), 37 kW at 660...690 V AC 50 Hz (AC-3e), 37 kW at 660...690 V AC 50 Hz (AC-3e), 37 kW at 660...690 V AC 50 Hz (AC-3e), 37 kW at 660...690 V AC 50 Hz (AC-3e), 37 kW at 660...690 V AC 50 Hz (AC-3e)
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 55...65 ms closing, 55...65 ms closing, 20...80 ms opening, 20...80 ms opening
    • Power Dissipation Per Pole : 9.6 W AC-1, 9.6 W AC-1, 6.3 W AC-3, 6.3 W AC-3, 6.3 W AC-3e, 6.3 W AC-3e
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6, power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6, power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6, power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6, power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6, power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6, power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4, power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4, power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4, power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4, power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5
    • ICW Rated Short Time Withstand Current : 110 A 40 °C - 10 min for power circuit, 110 A 40 °C - 10 min for power circuit, 110 A 40 °C - 10 min for power circuit, 110 A 40 °C - 10 min for power circuit, 260 A 40 °C - 1 min for power circuit, 260 A 40 °C - 1 min for power circuit, 260 A 40 °C - 1 min for power circuit, 260 A 40 °C - 1 min for power circuit, 640 A 40 °C - 10 s for power circuit, 640 A 40 °C - 10 s for power circuit, 640 A 40 °C - 10 s for power circuit, 640 A 40 °C - 10 s for power circuit, 900 A 40 °C - 1 s for power circuit, 900 A 40 °C - 1 s for power circuit, 900 A 40 °C - 1 s for power circuit, 900 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • IE Rated Operational Current : 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 80 A (at <60 °C) at <= 440 V AC-1 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit, 65 A (at <60 °C) at <= 440 V AC-3e for power circuit
    • ITH Conventional Free Air Thermal Current : 80 A (at 60 °C) for power circuit, 80 A (at 60 °C) for power circuit, 80 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit, 10 A (at 60 °C) for signalling circuit, 10 A (at 60 °C) for signalling circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.10191524952277248, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1.4745321097755628, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.1 kg CO2 eq., 0.06610966861825177
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 7 kg CO2 eq., 6.753680570165038
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 44 kg CO2 eq., 44.319760626556445
    • Connections Terminals : power circuit: lugs-ring terminals - external diameter: 16.5 mm, power circuit: lugs-ring terminals - external diameter: 16.5 mm, power circuit: lugs-ring terminals - external diameter: 16.5 mm, control circuit: lugs-ring terminals - external diameter: 8 mm, control circuit: lugs-ring terminals - external diameter: 8 mm, control circuit: lugs-ring terminals - external diameter: 8 mm
    • Auxiliaries : LADN226, LADN116, LADN406, LADN206, LADN316, LADT26, LADR06, LADN026
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1607010
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Coil Technology : built-in bidirectional peak limiting
    • Compatibility Code : LC1D
    • Device Short Name : LC1D
    • Halogen Free Status : Halogen free plastic parts and cables product
    • Package Weight Lbs : 990 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca Advanced
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 53 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1607010EN
    • Pep Verification Date : 2025-07-25
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Climatic Withstand : IACS E10 exposure to damp heat, IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • IP Degree Of Protection : IP20 front face IEC 60529, IP20 front face IEC 60529, IP20 front face IEC 60529
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C, 60-70 °C with derating, 60-70 °C with derating
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold, Reference contains Substances of Very High Concern above the threshold
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Halogene Performance : Halogen free plastic parts & cables product
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 52.71599822463807
    • Circularity Profile : ENVEOLI1607010
    • Environmental Disclosure : ENVPEP1607010EN
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Pep Code : ENVPEP1607010EN
    • Pep Verification Date : 2025-07-25
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca Advanced
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months