SQUARE D

IEC contactor, TeSys D, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, low consumption 72VDC, open style

IEC CONTACTOR, TESYS D, NONREV

SQDLC1D096SLS207 LC1D096SLS207 3389118234222
169.83 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys Deca contactor, 3 poles (3NO), for motor control in railway applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a low consumption 72V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Multi standards certified (IEC, CCC, EAC) and compliant with the railway European standard EN 45545 R22HL3. Contactor is supplied with a low consumption 72 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as stanard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control in railway applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a low consumption 72V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Multi standards certified (IEC, CCC, EAC) and compliant with the railway European standard EN 45545 R22HL3. Contactor is supplied with a low consumption 72 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as stanard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : EN/IEC 60947-4-1, EN/IEC 60947-5-1, EN 45545: R22 HL3, EN 45545: R22 HL3, EN 45545: R26 HL3, EN 45545: R26 HL3, DIN 5510-2
  • Complementary Attributes
    • Control Circuit Type : DC low consumption, DC low consumption
    • Control Circuit Voltage Limits : 0.1...0.25 Uc (-40-70 °C):drop-out DC, 0.1...0.25 Uc (-40-70 °C):drop-out DC, 0.1...0.25 Uc (-40-70 °C):drop-out DC, 0.1...0.25 Uc (-40-70 °C):drop-out DC, 0.7...1.25 Uc (-40-70 °C):operational DC, 0.7...1.25 Uc (-40-70 °C):operational DC, 0.7...1.25 Uc (-40-70 °C):operational DC, 0.7...1.25 Uc (-40-70 °C):operational DC
    • IRMS Rated Making Capacity : 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Maximum Operating Rate : 3600 cyc/h 60 °C, 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit, 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit, 17 V for signalling circuit
    • Rated Breaking Capacity : 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A at 440 V for power circuit conforming to IEC 60947
    • ICW Rated Short Time Withstand Current : 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit
    • IE Rated Operational Current : 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • UC Control Circuit Voltage : 72 V DC, 72 V DC
    • UE Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz
    • UI Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1, power circuit 690 V IEC 60947-4-1, power circuit 690 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1, signalling circuit 690 V IEC 60947-1, signalling circuit 690 V IEC 60947-1
    • UIMP Rated Impulse Withstand Voltage : 6 kV IEC 60947, 6 kV IEC 60947
  • Important Information Attributes
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at <= 690 V coordination type 1 for power circuit, 25 A gG at <= 690 V coordination type 1 for power circuit, 25 A gG at <= 690 V coordination type 1 for power circuit, 25 A gG at <= 690 V coordination type 1 for power circuit, 25 A gG at <= 690 V coordination type 1 for power circuit, 20 A gG at <= 690 V coordination type 2 for power circuit, 20 A gG at <= 690 V coordination type 2 for power circuit, 20 A gG at <= 690 V coordination type 2 for power circuit, 20 A gG at <= 690 V coordination type 2 for power circuit, 20 A gG at <= 690 V coordination type 2 for power circuit
    • Average Impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit, 2.5 mOhm - Ith 25 A 50 Hz for power circuit, 2.5 mOhm - Ith 25 A 50 Hz for power circuit, 2.5 mOhm - Ith 25 A 50 Hz for power circuit
    • Contactor Application : resistive load, motor control
    • Electrical Durability : 0.6 Mcycles 25 A AC-1 <= 440 V, 0.6 Mcycles 25 A AC-1 <= 440 V, 0.6 Mcycles 25 A AC-1 <= 440 V, 0.6 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 9 A AC-3 <= 440 V, 2 Mcycles 9 A AC-3 <= 440 V, 2 Mcycles 9 A AC-3 <= 440 V, 2 Mcycles 9 A AC-3 <= 440 V, 2 Mcycles 9 A AC-3e <= 440 V, 2 Mcycles 9 A AC-3e <= 440 V, 2 Mcycles 9 A AC-3e <= 440 V, 2 Mcycles 9 A AC-3e <= 440 V
    • Fire Resistance : 850 °C IEC 60695-2-1, 850 °C IEC 60695-2-1
    • Flame Retardance : V0 conforming to UL 94, V0 conforming to UL 94
    • Hold In Power Consumption In W : 4-4 W 20 °C, 4-4 W 20 °C
    • Inrush Power In W : 4-4 W 20 °C), 4-4 W 20 °C)
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor open 10 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms), shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
    • Motor Power KW : 2.2 kW at 220/230 V AC 50 Hz (AC-3), 2.2 kW at 220/230 V AC 50 Hz (AC-3), 2.2 kW at 220/230 V AC 50 Hz (AC-3), 2.2 kW at 220/230 V AC 50 Hz (AC-3), 2.2 kW at 220/230 V AC 50 Hz (AC-3), 4 kW at 380/400 V AC 50 Hz (AC-3), 4 kW at 380/400 V AC 50 Hz (AC-3), 4 kW at 380/400 V AC 50 Hz (AC-3), 4 kW at 380/400 V AC 50 Hz (AC-3), 4 kW at 380/400 V AC 50 Hz (AC-3), 4 kW at 415 V AC 50 Hz (AC-3), 4 kW at 415 V AC 50 Hz (AC-3), 4 kW at 415 V AC 50 Hz (AC-3), 4 kW at 415 V AC 50 Hz (AC-3), 4 kW at 415 V AC 50 Hz (AC-3), 4 kW at 440 V AC 50 Hz (AC-3), 4 kW at 440 V AC 50 Hz (AC-3), 4 kW at 440 V AC 50 Hz (AC-3), 4 kW at 440 V AC 50 Hz (AC-3), 4 kW at 440 V AC 50 Hz (AC-3), 5.5 kW at 500 V AC 50 Hz (AC-3), 5.5 kW at 500 V AC 50 Hz (AC-3), 5.5 kW at 500 V AC 50 Hz (AC-3), 5.5 kW at 500 V AC 50 Hz (AC-3), 5.5 kW at 500 V AC 50 Hz (AC-3), 5.5 kW at 660/690 V AC 50 Hz (AC-3), 5.5 kW at 660/690 V AC 50 Hz (AC-3), 5.5 kW at 660/690 V AC 50 Hz (AC-3), 5.5 kW at 660/690 V AC 50 Hz (AC-3), 5.5 kW at 660/690 V AC 50 Hz (AC-3), 2.2 kW at 220/230 V AC 50 Hz (AC-3e), 2.2 kW at 220/230 V AC 50 Hz (AC-3e), 2.2 kW at 220/230 V AC 50 Hz (AC-3e), 2.2 kW at 220/230 V AC 50 Hz (AC-3e), 2.2 kW at 220/230 V AC 50 Hz (AC-3e), 4 kW at 380/400 V AC 50 Hz (AC-3e), 4 kW at 380/400 V AC 50 Hz (AC-3e), 4 kW at 380/400 V AC 50 Hz (AC-3e), 4 kW at 380/400 V AC 50 Hz (AC-3e), 4 kW at 380/400 V AC 50 Hz (AC-3e), 4 kW at 415 V AC 50 Hz (AC-3e), 4 kW at 415 V AC 50 Hz (AC-3e), 4 kW at 415 V AC 50 Hz (AC-3e), 4 kW at 415 V AC 50 Hz (AC-3e), 4 kW at 415 V AC 50 Hz (AC-3e), 4 kW at 440 V AC 50 Hz (AC-3e), 4 kW at 440 V AC 50 Hz (AC-3e), 4 kW at 440 V AC 50 Hz (AC-3e), 4 kW at 440 V AC 50 Hz (AC-3e), 4 kW at 440 V AC 50 Hz (AC-3e), 5.5 kW at 500 V AC 50 Hz (AC-3e), 5.5 kW at 500 V AC 50 Hz (AC-3e), 5.5 kW at 500 V AC 50 Hz (AC-3e), 5.5 kW at 500 V AC 50 Hz (AC-3e), 5.5 kW at 500 V AC 50 Hz (AC-3e), 5.5 kW at 660/690 V AC 50 Hz (AC-3e), 5.5 kW at 660/690 V AC 50 Hz (AC-3e), 5.5 kW at 660/690 V AC 50 Hz (AC-3e), 5.5 kW at 660/690 V AC 50 Hz (AC-3e), 5.5 kW at 660/690 V AC 50 Hz (AC-3e)
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 77 ±15 % ms closing, 77 ±15 % ms closing, 25 ±20 % ms opening, 25 ±20 % ms opening
    • Power Dissipation Per Pole : 1.56 W AC-1, 1.56 W AC-1, 0.2 W AC-3, 0.2 W AC-3, 0.2 W AC-3e, 0.2 W AC-3e
    • Range : TeSys, TeSys Deca
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5
    • ICW Rated Short Time Withstand Current : 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 210 A 40 °C - 1 s for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 30 A 40 °C - 10 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit, 61 A 40 °C - 1 min for power circuit
    • IE Rated Operational Current : 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • ITH Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 10 A (at 60 °C) for signalling circuit, 10 A (at 60 °C) for signalling circuit, 25 A (at 60 °C) for power circuit, 25 A (at 60 °C) for power circuit, 25 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.9529548881344351, 1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1.208204740755529, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.03153297541368215
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 kg CO2 eq., 2.8213407946325786
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 15 kg CO2 eq., 14.924864966718363
    • Connections Terminals : control circuit: lugs-ring terminals - external diameter: 8 mm, control circuit: lugs-ring terminals - external diameter: 8 mm, control circuit: lugs-ring terminals - external diameter: 8 mm, power circuit: lugs-ring terminals - external diameter: 9.5 mm, power circuit: lugs-ring terminals - external diameter: 9.5 mm, power circuit: lugs-ring terminals - external diameter: 9.5 mm
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 1 - GSC certified
    • Persona Type Ids : OM8
    • Persona Type Names : OEM - Control Panelbuilder
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Coil Technology : with integral suppression device
    • Compatibility Code : LC1D
    • Contact Compatibility : M5
    • Device Short Name : LC1D
    • Package Weight Lbs : 501.000 g
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
    • Returnability : No
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 20 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-11
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Climatic Withstand : IACS E10, IEC 60947-1 Annex Q category D
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • IP Degree Of Protection : IP20 front face IEC 60529, IP20 front face IEC 60529, IP20 front face IEC 60529
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold, Reference contains Substances of Very High Concern above the threshold
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 19.93889836565459
    • Ambient Air Temperature For Operation : -40-70 °C
    • Environmental Disclosure : ENVPEP1501004EN
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-11
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months