IEC contactor, TeSys D, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, low consumption 72VDC, open style

IEC contactor, TeSys D, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, low consumption 72VDC, open style

SQDLC1D096SLS207 LC1D096SLS207 3389118234222
172.45 / EA
http://schema.org/OutOfStock
  • Country of Origin: France
  • Depth: 95 mm
  • Warranty Length: 18 mth
TeSys Deca contactor, 3 poles (3NO), for motor control in railway applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a low consumption 72V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Multi standards certified (IEC, CCC, EAC) and compliant with the railway European standard EN 45545 R22HL3. Contactor is supplied with a low consumption 72 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as stanard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for motor control in railway applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a low consumption 72V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Multi standards certified (IEC, CCC, EAC) and compliant with the railway European standard EN 45545 R22HL3. Contactor is supplied with a low consumption 72 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as stanard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Irms Rated Making Capacity : 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Control Circuit Type : DC low consumption
    • Control Circuit Voltage Limits : 0.1...0.25 Uc (-40-70 °C):drop-out DC0.7...1.25 Uc (-40-70 °C):operational DC
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 250 A at 440 V for power circuit conforming to IEC 60947
  • Important Information Attributes
    • Contactor Application : resistive load, motor control
    • Electrical Durability : 0.6 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 9 A AC-3 <= 440 V, 2 Mcycles 9 A AC-3e <= 440 V
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz)vibrations contactor closed 4 Gn, 5...300 Hz)shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
    • Motor Power Kw : 4 kW at 380/400 V AC 50 Hz (AC-3e), 4 kW at 415 V AC 50 Hz (AC-3e), 4 kW at 440 V AC 50 Hz (AC-3e), 5.5 kW at 500 V AC 50 Hz (AC-3e), 5.5 kW at 660/690 V AC 50 Hz (AC-3e)2.2 kW at 220/230 V AC 50 Hz (AC-3)4 kW at 380/400 V AC 50 Hz (AC-3), 4 kW at 415 V AC 50 Hz (AC-3), 4 kW at 440 V AC 50 Hz (AC-3)5.5 kW at 500 V AC 50 Hz (AC-3), 5.5 kW at 660/690 V AC 50 Hz (AC-3), 2.2 kW at 220/230 V AC 50 Hz (AC-3e)
    • Mounting Support : rail, plate
    • Power Dissipation Per Pole : 1.56 W AC-10.2 W AC-3, 0.2 W AC-3e
    • Range : TeSys, TeSys Deca
    • Tightening Torque : power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5power circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5
    • Utilisation Category : AC-3, AC-1, AC-3e
    • Certificate Agency : IEC, CCC, EAC, UA, TR, UKCA
    • [Icw] Rated Short-time Withstand Current : 100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit105 A 40 °C - 10 s for power circuit, 210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit
    • [Ie] Rated Operational Current : 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • Non-overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Carbon Footprint Of The Distribution Phase [A4] : 0.9529548881344351, 1 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 1.208204740755529, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0 kg CO2 eq., 0.03153297541368215
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 3 kg CO2 eq., 2.8213407946325786
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 15 kg CO2 eq., 14.924864966718363
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 2538
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • China Rohs Label : 3
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Persona Type Ids : OM8
    • Persona Type Names : OEM - Control Panelbuilder
    • Tier Id : 2
    • Tier : 2
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-125 A gG at <= 690 V coordination type 1 for power circuit20 A gG at <= 690 V coordination type 2 for power circuit
    • Average Impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit
    • Coil Technology : with integral suppression device
    • Compatibility Code : LC1D
    • Contact Compatibility : M5
    • Device Short Name : LC1D
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V0 conforming to UL 94
    • Inrush Power In W : 4-4 W 20 °C)
    • Mechanical Durability : 30 Mcycles
    • Number Of Poles : 3P
    • Operating Time : 77 ±15 % ms closing25 ±20 % ms opening
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : TeSys Deca
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
    • Returnability : No
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v6.1
    • Sustainable Packaging : Yes
    • Time Constant : 37 ms
    • Total Lifecycle Carbon Footprint : 20 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pole Contact Comp : 3 NO
    • Control Circuit Voltage 18 Control Circuit Voltage : 72 V
    • Control Circuit Type 1 Coil Type : low consumption
    • Pep Code : ENVPEP2205004EN
    • Database Version : 2023-02
    • Pep Verification Date : 2025-08-11
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 223.38
    • Energy Model - Manufacturing [A1-a3] : France, FR
    • Energy Model - Installation [A5] : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model - Use [B6] : Electricity Mix; Low voltage; 2018; France, FR
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Low voltage; 2018; France, FR
    • Recyclability Potential In % : 73
    • Height Nominal : 77 mm
    • Width Nominal : 45 mm
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit25 A (at 60 °C) for power circuit
    • [Uc] Control Circuit Voltage : 72 V DC
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • [Ui] Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1signalling circuit 690 V IEC 60947-1
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Connections - Terminals : control circuit: lugs-ring terminals - external diameter: 8 mmpower circuit: lugs-ring terminals - external diameter: 9.5 mm
    • Hold-in Power Consumption In W : 4-4 W 20 °C
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 501.000 g
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536490065
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Storage : -60-80 °C, -60-80 °C
    • Climatic Withstand : IACS E10, IEC 60947-1 Annex Q category D
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 19.93889836565459
    • Ambient Air Temperature For Operation : -40-70 °C-40-70 °C
    • Environmental Disclosure : ENVPEP2205004EN
    • Eu Rohs Directive : Compliant By Exemption
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2205004EN
    • Pep Verification Date : 2025-08-11
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : France
    • Depth : 95 mm