  • Depth: 186 mm
  • Warranty Length: 18 mth
TeSys Deca contactor, 3P(3NO) for category AC-3/AC-3e applications up to 95A @440V. It provides with 24V DC standard coil, with 1NO+1NC auxiliary contacts, power and control connections by screw clamp terminals. It procures high reliability and durability with 10 Mcycles mechanical durability and 1.2 Mcycles electrical durability. It provides IP20 protection on front face conforming to IEC 60529. It can cover -40°C to 60°C operation temperature and without derating under 3000m altitude. Designed for demanding applications with maximum operating rates up to 3600 cycles per hour under maximum 60°C. The dimension is 127mm x 85mm x 186mm (H x W x D), mounting on rail or plate. Contactor is supplied with a 24 VDC coil
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3P(3NO) for category AC-3/AC-3e applications up to 95A @440V. It provides with 24V DC standard coil, with 1NO+1NC auxiliary contacts, power and control connections by screw clamp terminals. It procures high reliability and durability with 10 Mcycles mechanical durability and 1.2 Mcycles electrical durability. It provides IP20 protection on front face conforming to IEC 60529. It can cover -40°C to 60°C operation temperature and without derating under 3000m altitude. Designed for demanding applications with maximum operating rates up to 3600 cycles per hour under maximum 60°C. The dimension is 127mm x 85mm x 186mm (H x W x D), mounting on rail or plate. Contactor is supplied with a 24 VDC coil
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Irms Rated Making Capacity : 1100 A at 440 V AC for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Maximum Horse Power Rating : 30 hp at 230/240 V AC 60 Hz for 3 phase motors7.5 hp at 120 V AC 60 Hz for 1 phase motors15 hp at 230/240 V AC 60 Hz for 1 phase motors, 30 hp at 200/208 V AC 60 Hz for 3 phase motors60 hp at 460/480 V AC 60 Hz for 3 phase motors, 60 hp at 575/600 V AC 60 Hz for 3 phase motors
    • Control Circuit Type : DC standard
    • Control Circuit Voltage Limits : 0.1...0.3 Uc (-40-70 °C):drop-out DC0.85...1.1 Uc (-40-55 °C):operational DC1...1.1 Uc (55-70 °C):operational DC
    • Maximum Motor Phase Current : 95 A
    • Maximum Operating Rate : 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Contactor Application : motor control, resistive load
    • Electrical Durability : 1.2 Mcycles 95 A AC-3, 1.3 Mcycles 125 A AC-1, 1.2 Mcycles 95 A AC-3e
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz)shocks contactor open 8 Gn for 11 ms)vibrations contactor closed 3 Gn, 5...300 Hz), shocks contactor closed 10 Gn for 11 ms)
    • Motor Power Kw : 45 kW at 380...400 V AC 50 Hz (AC-3e), 45 kW at 415...440 V AC 50 Hz (AC-3e), 55 kW at 500 V AC 50 Hz (AC-3e), 45 kW at 660...690 V AC 50 Hz (AC-3e), 25 kW at 220...230 V AC 50 Hz (AC-3)45 kW at 380...400 V AC 50 Hz (AC-3), 45 kW at 415...440 V AC 50 Hz (AC-3)55 kW at 500 V AC 50 Hz (AC-3), 45 kW at 660...690 V AC 50 Hz (AC-3), 25 kW at 220...230 V AC 50 Hz (AC-3e), 15 kW at 400 V AC 50 Hz (AC-4)
    • Mounting Support : rail, plate
    • Power Dissipation Per Pole : 12.5 W AC-17.2 W AC-3, 7.2 W AC-3e
    • Tightening Torque : power circuit 5 N.m bars hexagonal 10 mm M6, control circuit 1.2 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.2 N.m lugs-ring terminals Philips No 2 M3.5power circuit 5 N.m lugs-ring terminals flat Ø 8 mm M6power circuit 5 N.m lugs-ring terminals hexagonal 10 mm M6, power circuit 5 N.m bars flat Ø 8 mm M6control circuit 1.2 N.m screw clamp terminals pozidriv No 2 M3.5
    • Utilisation Category : AC-3, AC-3e, AC-4, AC-1
    • Control Circuit Voltage : 24 V
    • Certificate Agency : IECEE CB Scheme, CCC, EAC, LROS (Lloyds register of shipping), RINA, BV, DNV-GL
    • [Icw] Rated Short-time Withstand Current : 1100 A 40 °C - 1 s for power circuit800 A 40 °C - 10 s for power circuit400 A 40 °C - 1 min for power circuit135 A 40 °C - 10 min for power circuit, 140 A - 100 ms for signalling circuit120 A - 500 ms for signalling circuit, 100 A - 1 s for signalling circuit
    • [Ie] Rated Operational Current : 95 A (at <60 °C) at <= 440 V AC-3 for power circuit, 125 A (at <60 °C) at <= 1000 V AC-1 for power circuit, 95 A (at <60 °C) at <= 440 V AC-3e for power circuit
    • [Ui] Rated Insulation Voltage : power circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    • Connections - Terminals : lugs-ring terminals, control circuit: lugs-ring terminals - external diameter: 8 mmpower circuit: bars 1 - busbar cross section: 3 x 16 mm, power circuit: lugs-ring terminals - external diameter: 17 mm
    • Non-overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Carbon Footprint Of The Distribution Phase [A4] : 0.3416810635410429, 0.3 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 6.461453621222985, 6 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0.5 kg CO2 eq., 0.4899056242009124
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 17 kg CO2 eq., 17.320171625437503
    • Carbon Footprint Of The Use Phase [B2 B3 B4 B6] : 160 kg CO2 eq., 160.36942028985501
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-06-27
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1924
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1200 A gG at <= 690 V coordination type 1 for power circuit160 A gG at <= 690 V coordination type 2 for power circuit
    • Average Impedance : 0.8 mOhm - Ith 125 A 50 Hz for power circuit
    • Coil Technology : without built-in suppressor module
    • Compatibility Code : LC1D
    • Contact Compatibility : M9
    • Device Short Name : LC1D
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Inrush Power In W : 22-22 W 20 °C)
    • Mechanical Durability : 10 Mcycles
    • Number Of Poles : 3P
    • Operating Time : 95...130 ms closing20...35 ms opening
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Protective Treatment : THIEC 60068-2-30
    • Range : TeSys
    • Range Of Product : TeSys Deca
    • Returnability : No
    • Safety Reliability Level : B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Time Constant : 75 ms
    • Total Lifecycle Carbon Footprint : 185 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Connections Terminals : lugs-ring terminals
    • Inf Motor Phase Current : 95 A
    • Pep Code : ENVPEP1102005EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control. The functional unit is characterized by a type 3P(3NO), a control circuit voltage 230V AC, a power circuit voltage 690V and a rated operational current 80A
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime In Y : 20
    • Energy Consumption On Product Lifetime In Kwh : 2400.24
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; CZ
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; FR
    • Recyclability Potential In % : 76
    • Height Nominal : 127 mm
    • Width Nominal : 85 mm
    • [Ith] Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit125 A (at 60 °C) for power circuit
    • [Uc] Control Circuit Voltage : 24 V24 V DC
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947
    • Hold-in Power Consumption In W : 22-22 W 20 °C
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 2.34 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Customs Code : 8536490065
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 184.98263222425743
    • Climatic Withstand : IACS E10 exposure to damp heat
    • Environmental Disclosure : ENVPEP1102005EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C-40-60 °C60-70 °C with derating
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1102005EN
    • Pep Verification Date : 2025-08-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil, Czechia, France
    • Depth : 186 mm