IEC contactor, TeSys D, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style

IEC contactor, TeSys D, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style

SQDLC1D80AG7 LC1D80AG7 3606481312150
388.32 / EA
  • Certifications: CCC, CSA, DNV-GL, EAC, KC, LROS (Lloyds Register Of Shipping), UKCA, UL
  • Color: Gray SE GREY 6)
  • Contact Configuration: 1 NO + 1 NC
  • Contact Configuration: 3 NO
  • Depth: 120 mm
  • Height: 122 mm
  • Impedance: 1.5 MOhm - Ith 80 A 50 Hz Power Circuit
  • Net Weight: 0.86 kg
  • Standard: CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1
  • Storage Temperature: -60-80 °C
  • Warranty Length: 18 mth
  • Width: 55 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Environment
    • Ambient Air Temperature For Operation : -40-60 °C || 60-70 °C with derating
    • Mechanical Robustness : vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open10 Gn for 11 ms
    • Net Weight : 0.86 kg
    • Maximum Depth : 120 mm
    • Pollution Degree : 3
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Protective Treatment : TH IEC 60068-2-30
    • Maximum Height : 122 mm
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Maximum Width : 55 mm
    • Ambient Air Temperature For Storage : -60-80 °C
    • Color : Gray SE GREY 6)
    • Flame Retardance : V1 conforming to UL 94
  • Control Circuit Type : AC 60 Hz
  • Standards : EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
  • [Ie] Rated Operational Current : 80 A 60 °C) <= 440 V AC-1 power circuit || 66 A 60 °C) <= 440 V AC-3 power circuit
  • Electrical Durability : 0.7 Mcycles 80 A AC-1 <= 440 V || 1 Mcycles 66 A AC-3 <= 440 V
  • Device Short Name : LC1D
  • Protective Cover : with
  • Associated Fuse Rating : 10 A gG signalling circuit IEC 60947-5-1 || 125 A gG <= 690 V type 1 power circuit || 125 A gG <= 690 V type 2 power circuit
  • Product Or Component Type : contactor
  • Motor Power Kw : 18.5 kW 220...230 V AC 50 Hz AC-3) || 37 kW 380...400 V AC 50 Hz AC-3) || 37 kW 415 V AC 50 Hz AC-3) || 37 kW 440 V AC 50 Hz AC-3) || 37 kW 500 V AC 50 Hz AC-3) || 37 kW 660...690 V AC 50 Hz AC-3)
  • Product Certifications : CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
  • Average Impedance : 1.5 mOhm - Ith 80 A 50 Hz power circuit
  • Range : TeSys
  • [Ui] Rated Insulation Voltage : signalling circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-4-1
  • Mounting Support : plate || rail
  • Pole Contact Composition : 3 NO
  • [Icw] Rated Short-Time Withstand Current : 520 A 40 °C - 10 s power circuit || 900 A 40 °C - 1 s power circuit || 110 A 40 °C - 10 min power circuit || 260 A 40 °C - 1 min power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
  • Maximum Operating Rate : 3600 cyc/h 60 °C
  • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • Utilisation Category : AC-1 || AC-3
  • Poles Description : 3P
  • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Contactor Application : motor control || resistive load
  • Mechanical Durability : 6 Mcycles
  • [Uc] Control Circuit Voltage : 120 V AC 60 Hz
  • Irms Rated Making Capacity : 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1 || 1000 A 440 V AC power circuit IEC 60947
  • Maximum Horse Power Rating : 5 hp 115 V at AC 60 Hz for 1 phase || 10 hp 230/240 V at AC 60 Hz for 1 phase || 20 hp 200/208 V at AC 60 Hz for 3 phase || 20 hp 230/240 V at AC 60 Hz for 3 phase || 40 hp 460/480 V at AC 60 Hz for 3 phase || 50 hp 575/600 V at AC 60 Hz for 3 phase
  • Product Name : TeSys D
  • Power Dissipation Per Pole : 9.6 W AC-1 || 6.5 W AC-3
  • Overvoltage Category : III
  • [Ue] Rated Operational Voltage : power circuit 690 V AC 25...400 Hz || power circuit 300 V DC
  • [Ith] Conventional Free Air Thermal Current : 10 A 60 °C signalling circuit || 80 A 60 °C power circuit
  • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connectors 1-25 mm² hexagonal 4 mm
  • Connections - Terminals : control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit EverLink BTR screw connectors 1 1-35 mm²flexible with cable end || power circuit EverLink BTR screw connectors 2 1-25 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid || power circuit EverLink BTR screw connectors 1 1-35 mm²solid || power circuit EverLink BTR screw connectors 2 1-25 mm²solid || control circuit screw clamp terminals 1 1-4 mm²flexible || control circuit screw clamp terminals 2 1-4 mm²flexible || power circuit EverLink BTR screw connectors 1 1-35 mm²flexible || power circuit EverLink BTR screw connectors 2 1-25 mm²flexible
  • Auxiliary Contact Composition : 1 NO + 1 NC
  • Rated Breaking Capacity : 1000 A 440 V power circuit IEC 60947
  • Operating Time : 4...19 ms opening || 12...26 ms closing
  • Offer Sustainability
    • Sustainable Offer Status : Green Premium product
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Pvc Free : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Free Of Svhc : Yes
    • Eu Rohs Directive : Compliant
    • Environmental Disclosure : ENVPEP110205EN
    • Mercury Free : Yes
    • Rohs Exemption Information : Yes
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
  • Complementary
    • Control Circuit Voltage Limits : 0.3...0.6 Uc -40-70 °C drop-out AC 60 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 60 Hz
    • Hold-In Power Consumption In Va : 13-13 VA 60 Hz 0.3 20 °C)
    • Minimum Switching Voltage : 17 V signalling circuit
    • Heat Dissipation : 4-5 W 60 Hz
    • Signalling Circuit Frequency : 25...400 Hz
    • Coil Technology : without built-in suppressor module
    • Minimum Switching Current : 5 mA signalling circuit
    • Non-Overlap Time : 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
    • Auxiliary Contacts Type : mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
    • Insulation Resistance : > 10 MOhm signalling circuit
    • Inrush Power In Va : 140-140 VA 60 Hz 0.75 20 °C)
  • Contractual warranty
    • Warranty : 18 months