IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 415VAC 50/60Hz coil, open

IEC contactor, TeSys D, nonrev

SQDLC1D65N7 3389110437416
444.00 / EA
http://schema.org/OutOfStock
  • Certifications: BV, CCC, CSA, DNV, GOST, LROS (Lloyds Register Of Shipping), RINA, UKCA, UL
  • Contact Configuration: 1 NO + 1 NC, 3 NO
  • Depth: 118 mm
  • Height: 122 mm
  • Impedance: 1.5 Ohm - Ith 80 A 50 Hz For Power Circuit
  • Net Weight: 2.185 kg
  • Standard: CSA C22.2 No 14, EN 60947-4-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Warranty Length: 18 mth
  • Width: 70 mm
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 415 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
QTY
  • Product Description
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 415 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
  • Environment
    • Product Certifications : GOST || CSA || DNV || UL || CCC || LROS (Lloyds register of shipping) || BV || RINA || UKCA
    • Height : 122 mm
    • Standards : IEC 60947-5-1 || EN 60947-4-1 || IEC 60947-4-1 || UL 508 || CSA C22.2 No 14
    • Climatic Withstand : IACS E10 exposure to damp heat
    • Net Weight : 2.185 kg
    • Flame Retardance : V1 conforming to UL 94
    • Protective Treatment : TH 3)IEC 60068-2-30
    • Ip Degree Of Protection : IP2X VDE 0106 || IP2X IEC 60529
    • Mechanical Robustness : shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor opened 10 Gn for 11 ms)
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Quantity Per Set : set of 10
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Width : 70 mm
    • Depth : 118 mm
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP110205EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Rohs Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Circularity Profile : N/A
    • Eu Rohs Directive : Compliant
  • Complementary
    • Non-Overlap Time : 1.5 ms on energisation between NC and NO contacts || 1.5 ms on de-energisation between NC and NO contacts
    • Minimum Switching Current : 5 mA for control circuit
    • Power Dissipation Per Pole : 6.4 W AC-1 || 4.2 W AC-3e || 6.3 W AC-3 || 9.6 W AC-1
    • Average Impedance : 1.5 Ohm - Ith 80 A 50 Hz for power circuit
    • Auxiliary Contact Composition : 1 NO + 1 NC
    • Terminals Description Iso N°1 : (13-14)NO || (21-22)NC
    • [Ith] Conventional Free Air Thermal Current : 80 A (at 60 °C) for power circuit || 10 A (at 60 °C) for control circuit
    • Control Circuit Voltage Limits : 0.8...1.1 Uc -40-60 °C operational AC 50 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz || 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz
    • Mounting Support : rail
    • Control Circuit Type : AC 50/60 Hz
    • Safety Reliability Level : B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Insulation Resistance : > 10 MOhm for control circuit
    • Rated Breaking Capacity : 1000 kA at 440 V for power circuit conforming to IEC 60947
    • Irms Rated Making Capacity : 140 A at 440 V AC for control circuit conforming to IEC 60947-5-1 || 140 A AC for control circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
    • Associated Fuse Rating : 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1 || 10 A gG for control circuit conforming to IEC 60947-5-1
    • Inrush Power In Va : 160-160 VA cos phi 0.75 (at 20 °C) || 140-140 VA cos phi 0.75 (at 20 °C)
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947
    • Pole Contact Composition : 3 NO
    • Connections - Terminals : control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: rigid || power circuit: screw terminals 2 2.5-16 mm² - cable stiffness: rigid without cable end || power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end || power circuit: screw terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end || power circuit: screw terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end || power circuit: screw terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: rigid
    • Coil Technology : without built-in
    • Operating Time : 12...26 ms closing || 4...19 ms opening
    • Minimum Switching Voltage : 17 V for control circuit
    • Maximum Operating Rate : 3600 cyc/mn 60 °C
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm || control circuit 1.7 N.m screw clamp terminal pozidriv No 2 || control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm
    • Mechanical Durability : 6000000 cycles
    • Auxiliary Contacts Type : mirror contact 1 NC IEC 60947-4-1 || mechanically linked 1 NO + 1 NC IEC 60947-5-1
    • Compatibility Code : LC1D
    • Hold-In Power Consumption In Va : 15-15 VA 50 Hz cos phi 0.3 (at 20 °C) || 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
    • Overvoltage Category : III
    • Maximum Horse Power Rating : 10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 50 hp at 575/600 V AC 60 Hz for 3 phase motors || 5 hp at 115 V AC 60 Hz for 1 phase motors
    • Motor Power Kw : 11 kW at 400 V AC 50 Hz (AC-4) || 30 kW at 380...400 V AC 50 Hz (AC-3) || 37 kW at 500 V AC 50 Hz (AC-3) || 37 kW at 660...690 V AC 50 Hz (AC-3) || 18.5 kW at 220...230 V AC 50 Hz (AC-3) || 30 kW at 415 V AC 50 Hz (AC-3) || 37 kW at 1000 V AC 50 Hz (AC-3) || 30 kW at 440 V AC 50 Hz (AC-3e) || 30 kW at 380...400 V AC 50 Hz (AC-3e) || 37 kW at 500 V AC 50 Hz (AC-3e) || 37 kW at 660...690 V AC 50 Hz (AC-3e) || 18.5 kW at 220...230 V AC 50 Hz (AC-3e) || 30 kW at 415 V AC 50 Hz (AC-3e) || 37 kW at 1000 V AC 50 Hz (AC-3e) || 37 kW at 500 V AC 50 Hz || 30 kW at 380...400 V AC 50 Hz
    • [Ui] Rated Insulation Voltage : control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL IEC 60947-1 || control circuit 690 V IEC 60947-1 || power circuit 690 V CSA IEC 60947-1 || control circuit 600 V CSA
    • [Icw] Rated Short-Time Withstand Current : 520 A 40 °C - 10 s for power circuit || 900 A 40 °C - 1 s for power circuit
    • Heat Dissipation : 4-5 W at 50/60 Hz for control circuit
    • Protective Cover : with
  • Specifications
    • [Uc] Control Circuit Voltage : 415 V AC 50/60 Hz
    • [Ue] Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz
    • Range Of Product : TeSys Deca
    • Contactor Application : resistive load || motor control
    • Product Or Component Type : contactor
    • Range : TeSys
    • Utilisation Category : AC-1 || AC-2 || AC-3 || AC-3e
    • [Ie] Rated Operational Current : 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 65 A (at <60 °C) at 415 V AC AC-3 for power circuit || 80 A (at <60 °C) at 415 V AC AC-1 for power circuit
    • Poles Description : 3P
    • Device Short Name : LC1D