SQUARE D

IEC contactor, TeSys D, nonreversing, 25A, 15HP at 480VAC, 3 phase, 3 pole, 3 NO, 72VDC coil, open style

IEC contactor, TeSys D, nonreversing, 25A, 15HP at 480VAC, 3 phase, 3 pole, 3 NO, 72VDC coil, open style

SQDLC1D256SD LC1D256SD 3389110807745
234.54 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 25A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 7.5HP at 240VAC, 15HP at 480VAC and 20HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a 72 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.98 inches deep. It weighs 1.17 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
QTY
  • Product Description
  • Features
  • Specifications
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 25A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 7.5HP at 240VAC, 15HP at 480VAC and 20HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a 72 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.98 inches deep. It weighs 1.17 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, IEC 60335-1:Clause 30.2, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, CSA C22.2 No 60947-4-1
  • Complementary Attributes
    • Control Circuit Type : DC standard, DC standard
    • Control Circuit Voltage Limits : 0.1...0.25 Uc (-40-70 °C):drop-out DC, 0.1...0.25 Uc (-40-70 °C):drop-out DC, 0.1...0.25 Uc (-40-70 °C):drop-out DC, 0.1...0.25 Uc (-40-70 °C):drop-out DC, 0.7...1.25 Uc (-40-60 °C):operational DC, 0.7...1.25 Uc (-40-60 °C):operational DC, 0.7...1.25 Uc (-40-60 °C):operational DC, 0.7...1.25 Uc (-40-60 °C):operational DC, 1...1.25 Uc (60-70 °C):operational DC, 1...1.25 Uc (60-70 °C):operational DC, 1...1.25 Uc (60-70 °C):operational DC, 1...1.25 Uc (60-70 °C):operational DC
    • IRMS Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947, 450 A at 440 V for power circuit conforming to IEC 60947, 450 A at 440 V for power circuit conforming to IEC 60947, 450 A at 440 V for power circuit conforming to IEC 60947
    • Maximum Horse Power Rating : 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors
    • Maximum Operating Rate : 3600 cyc/h at 60 °C, 3600 cyc/h at 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit, 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit, 17 V for signalling circuit
    • Rated Breaking Capacity : 450 A at 440 V for power circuit conforming to IEC 60947, 450 A at 440 V for power circuit conforming to IEC 60947, 450 A at 440 V for power circuit conforming to IEC 60947, 450 A at 440 V for power circuit conforming to IEC 60947
    • ICW Rated Short Time Withstand Current : 240 A 40 °C - 10 s for power circuit, 240 A 40 °C - 10 s for power circuit, 240 A 40 °C - 10 s for power circuit, 240 A 40 °C - 10 s for power circuit, 380 A 40 °C - 1 s for power circuit, 380 A 40 °C - 1 s for power circuit, 380 A 40 °C - 1 s for power circuit, 380 A 40 °C - 1 s for power circuit, 50 A 40 °C - 10 min for power circuit, 50 A 40 °C - 10 min for power circuit, 50 A 40 °C - 10 min for power circuit, 50 A 40 °C - 10 min for power circuit, 120 A 40 °C - 1 min for power circuit, 120 A 40 °C - 1 min for power circuit, 120 A 40 °C - 1 min for power circuit, 120 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • IE Rated Operational Current : 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • UC Control Circuit Voltage : 72 V DC, 72 V DC
    • UE Rated Operational Voltage : power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC, power circuit <= 300 V DC, power circuit <= 300 V DC
    • UI Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1, power circuit 690 V IEC 60947-4-1, power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V CSA, power circuit 600 V CSA, power circuit 600 V UL, power circuit 600 V UL, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 690 V IEC 60947-1, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V CSA, signalling circuit 600 V CSA, signalling circuit 600 V UL, signalling circuit 600 V UL, signalling circuit 600 V UL
    • UIMP Rated Impulse Withstand Voltage : 6 kV IEC 60947, 6 kV IEC 60947
    • Maximum Motor Phase Current : 25 A
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 1 for power circuit, 40 A gG at <= 690 V coordination type 2 for power circuit, 40 A gG at <= 690 V coordination type 2 for power circuit, 40 A gG at <= 690 V coordination type 2 for power circuit, 40 A gG at <= 690 V coordination type 2 for power circuit, 40 A gG at <= 690 V coordination type 2 for power circuit
    • Average Impedance : 2 mOhm - Ith 40 A 50 Hz for power circuit, 2 mOhm - Ith 40 A 50 Hz for power circuit, 2 mOhm - Ith 40 A 50 Hz for power circuit, 2 mOhm - Ith 40 A 50 Hz for power circuit
    • Contactor Application : resistive load, motor control
    • Electrical Durability : 1.65 Mcycles 25 A AC-3 <= 440 V, 1.65 Mcycles 25 A AC-3 <= 440 V, 1.65 Mcycles 25 A AC-3 <= 440 V, 1.65 Mcycles 25 A AC-3 <= 440 V, 1.4 Mcycles 40 A AC-1 <= 440 V, 1.4 Mcycles 40 A AC-1 <= 440 V, 1.4 Mcycles 40 A AC-1 <= 440 V, 1.4 Mcycles 40 A AC-1 <= 440 V, 1.65 Mcycles 25 A AC-3e <= 440 V, 1.65 Mcycles 25 A AC-3e <= 440 V, 1.65 Mcycles 25 A AC-3e <= 440 V, 1.65 Mcycles 25 A AC-3e <= 440 V
    • Fire Resistance : 850 °C IEC 60695-2-1, 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94, V1 conforming to UL 94
    • Hold In Power Consumption In W : 5.4-5.4 W 20 °C, 5.4-5.4 W 20 °C
    • Inrush Power In W : 5.4-5.4 W 20 °C), 5.4-5.4 W 20 °C)
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor closed 15 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms), shocks contactor open 8 Gn for 11 ms), shocks contactor open 8 Gn for 11 ms), shocks contactor open 8 Gn for 11 ms)
    • Motor Power KW : 5.5 kW at 220/230 V AC 50/60 Hz (AC-3), 5.5 kW at 220/230 V AC 50/60 Hz (AC-3), 5.5 kW at 220/230 V AC 50/60 Hz (AC-3), 5.5 kW at 220/230 V AC 50/60 Hz (AC-3), 5.5 kW at 220/230 V AC 50/60 Hz (AC-3), 11 kW at 380/400 V AC 50/60 Hz (AC-3), 11 kW at 380/400 V AC 50/60 Hz (AC-3), 11 kW at 380/400 V AC 50/60 Hz (AC-3), 11 kW at 380/400 V AC 50/60 Hz (AC-3), 11 kW at 380/400 V AC 50/60 Hz (AC-3), 11 kW at 415/440 V AC 50/60 Hz (AC-3), 11 kW at 415/440 V AC 50/60 Hz (AC-3), 11 kW at 415/440 V AC 50/60 Hz (AC-3), 11 kW at 415/440 V AC 50/60 Hz (AC-3), 11 kW at 415/440 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 660/690 V AC 50/60 Hz (AC-3), 15 kW at 660/690 V AC 50/60 Hz (AC-3), 15 kW at 660/690 V AC 50/60 Hz (AC-3), 15 kW at 660/690 V AC 50/60 Hz (AC-3), 15 kW at 660/690 V AC 50/60 Hz (AC-3), 5.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 5.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 5.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 5.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 5.5 kW at 220/230 V AC 50/60 Hz (AC-3e), 11 kW at 380/400 V AC 50/60 Hz (AC-3e), 11 kW at 380/400 V AC 50/60 Hz (AC-3e), 11 kW at 380/400 V AC 50/60 Hz (AC-3e), 11 kW at 380/400 V AC 50/60 Hz (AC-3e), 11 kW at 380/400 V AC 50/60 Hz (AC-3e), 11 kW at 415/440 V AC 50/60 Hz (AC-3e), 11 kW at 415/440 V AC 50/60 Hz (AC-3e), 11 kW at 415/440 V AC 50/60 Hz (AC-3e), 11 kW at 415/440 V AC 50/60 Hz (AC-3e), 11 kW at 415/440 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 660/690 V AC 50/60 Hz (AC-3e), 15 kW at 660/690 V AC 50/60 Hz (AC-3e), 15 kW at 660/690 V AC 50/60 Hz (AC-3e), 15 kW at 660/690 V AC 50/60 Hz (AC-3e), 15 kW at 660/690 V AC 50/60 Hz (AC-3e), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 400 V AC 50/60 Hz (AC-4)
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 63 ±15 % ms closing, 63 ±15 % ms closing, 20 ±20 % ms opening, 20 ±20 % ms opening
    • Power Dissipation Per Pole : 3.2 W AC-1, 3.2 W AC-1, 1.25 W AC-3, 1.25 W AC-3, 1.25 W AC-3e, 1.25 W AC-3e
    • Protective Treatment : THIEC 60068-2-30, THIEC 60068-2-30
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5, power circuit 2.5 N.m lugs-ring terminals flat Ø 8 mm M4, power circuit 2.5 N.m lugs-ring terminals flat Ø 8 mm M4, power circuit 2.5 N.m lugs-ring terminals flat Ø 8 mm M4, power circuit 2.5 N.m lugs-ring terminals flat Ø 8 mm M4, power circuit 2.5 N.m lugs-ring terminals flat Ø 8 mm M4, power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4, power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4, power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4, power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4, power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4
    • ICW Rated Short Time Withstand Current : 240 A 40 °C - 10 s for power circuit, 240 A 40 °C - 10 s for power circuit, 240 A 40 °C - 10 s for power circuit, 240 A 40 °C - 10 s for power circuit, 380 A 40 °C - 1 s for power circuit, 380 A 40 °C - 1 s for power circuit, 380 A 40 °C - 1 s for power circuit, 380 A 40 °C - 1 s for power circuit, 50 A 40 °C - 10 min for power circuit, 50 A 40 °C - 10 min for power circuit, 50 A 40 °C - 10 min for power circuit, 50 A 40 °C - 10 min for power circuit, 120 A 40 °C - 1 min for power circuit, 120 A 40 °C - 1 min for power circuit, 120 A 40 °C - 1 min for power circuit, 120 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • IE Rated Operational Current : 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    • ITH Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 10 A (at 60 °C) for signalling circuit, 10 A (at 60 °C) for signalling circuit, 40 A (at 60 °C) for power circuit, 40 A (at 60 °C) for power circuit, 40 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.16099369916532025, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 1.4107168668267351, 1 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0 kg CO2 eq., 0.044581888190333124
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 3 kg CO2 eq., 2.912955799545972
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 37 kg CO2 eq., 37.09321621621622
    • Connections Terminals : control circuit: lugs-ring terminals - external diameter: 8 mm, control circuit: lugs-ring terminals - external diameter: 8 mm, control circuit: lugs-ring terminals - external diameter: 8 mm, power circuit: lugs-ring terminals - external diameter: 10 mm, power circuit: lugs-ring terminals - external diameter: 10 mm, power circuit: lugs-ring terminals - external diameter: 10 mm
    • Auxiliaries : LAD6K10M, LADN226, LADN116, LADN406, LADN206
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1102030EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Compatibility Code : LC1D
    • Contact Compatibility : M4
    • Device Short Name : LC1D
    • Package Weight Lbs : 544.0 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
    • Returnability : Yes
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 42 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Add Ons : LAD4DDL
    • Pep Code : ENVPEP1102030EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3NO, a control circuit voltage 24V DC,a power circuit voltage 690V and a rated operational current 9A.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • Climatic Withstand : IACS E10 exposure to damp heat, IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • IP Degree Of Protection : IP20 front face IEC 60529, IP20 front face IEC 60529, IP20 front face IEC 60529
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C, 60-70 °C with derating, 60-70 °C with derating
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold, Reference contains Substances of Very High Concern above the threshold
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 41.622464469944575
    • Circularity Profile : ENVEOLI1102030EN
    • Environmental Disclosure : ENVPEP1102030EN
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Pep Code : ENVPEP1102030EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months