  • Depth: 122 mm
Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 50A/690V AC-3 (30HP@480V). It provides a 120 VAC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA).
QTY
  • Product Description
  • Features
  • Specifications
Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 50A/690V AC-3 (30HP@480V). It provides a 120 VAC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : cULus, CB Scheme, CE
    • Standards : UL 60947-1, UL 60947-4-1, CSA C22.2 No 60947-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1
  • Complementary Attributes
    • Control Circuit Voltage Limits : operational: 0.85...1.1 Uc at 60 Hz (at <60 °C), operational: 1...1.1 Uc at 60 Hz (at <70 °C), drop-out: 0.3...0.6 Uc at 60 Hz (at <70 °C)
    • Irms Rated Making Capacity : 140 A AC for signalling circuit, 250 A DC for signalling circuit, 800 A at 440 V for power circuit
    • Maximum Horse Power Rating : 10 hp at 230...240 V AC 50/60 Hz for 3 phase motors, 3 hp at 115 V AC 50/60 Hz for 1 phase motors, 5 hp at 230...240 V AC 50/60 Hz for 1 phase motors, 10 hp at 200...208 V AC 50/60 Hz for 3 phase motors, 30 hp at 460...480 V AC 50/60 Hz for 3 phase motors, 30 hp at 575...600 V AC 50/60 Hz for 3 phase motors
    • Ie Rated Operational Current : 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • Ue Rated Operational Voltage : 230...240 V 3-phase, 115 V single phase, 230...240 V single phase, 200...208 V 3-phase, 460...480 V 3-phase, 575...600 V 3-phase
    • Ui Rated Insulation Voltage : 690 V, 600 V
    • Control Circuit Type : AC 60 Hz
    • Maximum Motor Phase Current : 50 A
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 800 A at 440 V for power circuit
    • Uc Control Circuit Voltage : 120 V AC 60 Hz
    • Uimp Rated Impulse Withstand Voltage : 6 kV
  • Important Information Attributes
    • Persona Type Ids : OM, OM8, PB, SC
    • Persona Type Names : Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : RESIDENTIAL, COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Residential, Commercial, Industrial
    • Associated Fuse Rating : 100 A gG at <= 690 V coordination type 1 for power circuit, 100 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit
    • Contactor Application : motor control, resistive load
    • Disconnector Device Type : associated fuse, J fuse, 110 A at 600 V with 100 kA breaking capacity, associated circuit breaker, 110 A at 480 V with 35 kA breaking capacity, associated circuit breaker, 110 A at 600 V with 18 kA breaking capacity
    • Electrical Durability : 1 Mcycles 40 A AC-3 <= 440 V, 0.6 Mcycles 60 A AC-1 <= 440 V
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
    • Motor Power Kw : 15 kW 220...230 V AC 50/60 Hz, 22 kW 380...400 V AC 50/60 Hz, 25 kW 415 V AC 50/60 Hz, 30 kW 440 V AC 50/60 Hz, 30 kW 500 V AC 50/60 Hz, 33 kW 660...690 V AC 50/60 Hz
    • Mounting Support : rail, plate
    • Operating Time : 4...19 ms opening, 12...26 ms closing
    • Power Dissipation Per Pole : 3.7 W AC-3, 9.6 W AC-1
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : power circuit 7 N.m screw connectors 16-25 mm² hexagonal 4 mm, power circuit 5 N.m screw connectors 2.5-16 mm² hexagonal 4 mm, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2
    • Utilisation Category : AC-3, AC-1
    • Connections Terminals : power circuit: screw connection 2 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw connection 2 2.5-16 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw connection 1 2.5-25 mm² - cable stiffness: flexible without cable end, power circuit: screw connection 2 2.5-16 mm² - cable stiffness: flexible without cable end, power circuit: screw connection 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw connection 1 2.5-25 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
    • Ie Rated Operational Current : 50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • Ith Conventional Free Air Thermal Current : 80 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
    • Carbon Footprint Of The Distribution Phase A4 : 2.727763222546913, 3 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 4 kg CO2 eq., 3.822554669518983
    • Carbon Footprint Of The Installation Phase A5 : 0.0574439490046993, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 13 kg CO2 eq., 12.699016415047677
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 61 kg CO2 eq., 61.259758021595786
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-26
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1503009EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1926
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 1.5 mOhm
    • Coil Technology : without built-in suppressor module
    • Device Short Name : DPE
    • Energy Efficiency Optimized : False
    • Fire Resistance : 850 °C
    • Flame Retardance : V1 conforming to UL 94
    • Heat Dissipation : 4-5 W 60 Hz
    • Hold In Power Consumption In Va : 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
    • Inrush Power In Va : 140-140 VA 60 Hz cos phi 0.75 (at 20 °C)
    • Mechanical Durability : 5 Mcycles
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : Easy TeSys DPE
    • Product Or Component Type : contactor
    • Protective Treatment : TH
    • Range : Easy TeSys
    • Returnability : Yes
    • Signalling Circuit Frequency : 25...400 Hz
    • Software Version : v6.2.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 81 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Warranty In Months : 18
    • Inf Motor Phase Current : 50 A
    • Control Circuit Voltage 18 : 120 V AC 60 Hz
    • Pep Code : ENVPEP1503009EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-11-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Product Weight In G2 : 2216
    • Reference Lifetime In Y2 : 20
    • Energy Consumption On Product Lifetime In Kwh : 681.09
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; France, FR
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Recyclability Potential In 2 : 62
    • Offer Owner Code : 190788
    • Height Nominal : 122 mm
    • Width Nominal : 55 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Climatic Withstand : IACS E10, IEC 60947-1 Annex Q category D
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 80.56653627771405
    • Ambient Air Temperature For Operation : -40-60 °C
    • Ambient Air Temperature For Storage : -60-80 °C
    • Circularity Profile : ENVEOLI1503009EN
    • Environmental Disclosure : ENVPEP1503009EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 front face
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1503009EN
    • Pep Verification Date : 2025-11-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3-2023 06 06
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Output Attributes
    • Continuous Output Current : 70-70 A
  • Specifications
    • Depth : 122 mm