Hyde Park, Ultrasonic sensor, analog, voltage (V), 18 mm snout dual mount, 15 24 V DC

Hyde Park, Ultrasonic sensor,

SQDVM1VA0011Q VM1VA0011Q 3389119065160
181.07 / EA
http://schema.org/OutOfStock
  • Certifications: UL
  • Current: 40 mA
  • Depth: 43.7 mm
  • Enclosure Material: Valox
  • Height: 43.7 mm
  • Length: 65.61 mm
  • Material: Plastic
  • Net Weight: 0.033 kg
  • Warranty Length: 18 mth
  • Width: 18 mm
QTY
  • Specifications
  • Specifications
    • Iso Thread : M18 x 1
    • Type Of Sensing Window : adjustable
    • Series Name : Virtu VM1
    • Type Of Output Signal : analog
    • Range Of Product : Hyde Park
    • Supply Voltage Limits : 13-28 V DC
    • Sensor Type : ultrasonic sensor
    • Electrical Connection : male connector M12 4 pins
    • Sensor Design : flat form + cylindrical M18
    • Enclosure Material : valox
    • Front Material : glass epoxy
    • Material : plastic
    • Device Short Name : VM1
    • Analogue Output Range : 0...10 V autoslope
    • [Us] Rated Supply Voltage : 15...24 V DC overload and short-circuit protection
    • Wiring Technique : 4-wire
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Repeat Accuracy : 1.27 %
    • Beam Angle : 5 °
    • Height : 43.7 mm
    • Minimum Size Of Detected Object : cylinder diameter 2.5 mm - up to 200 mm sensing distance
    • Maximum Switching Current : 40 mA reverse polarity protection
    • Transmission Frequency : 300 kHz
    • Width : 18 mm
    • Depth : 43.7 mm
    • [Sn] Nominal Sensing Distance : 508-508 mm
    • Blind Zone : 51-51 mm
    • [Sd] Sensing Range : 50.8-508 mm
    • Length : 65.61 mm
    • Net Weight : 0.033 kg
    • Current Consumption : 40 mA
  • Offer Sustainability
    • Eu Rohs Directive : Not applicable, out of EU RoHS legal scope
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Environment
    • Product Certifications : UL
    • Ambient Air Temperature For Operation : -30-70 °C
    • Resistance To Electromagnetic Fields : 10 V/m level 3 IEC 61000-4-3
    • Ambient Air Temperature For Storage : -40-85 °C
    • Relative Humidity : 100-100 % without condensation
    • Nema Degree Of Protection : NEMA 4X indoor use only)
    • Vibration Resistance : +/-1 mm 10-55 Hz)IEC 60068-2-6
    • Shock Resistance : 30 gn in all 3 axes 11 ms IEC 60068-2-27
    • Marking : CE
    • Resistance To Fast Transients : 1 kV level 3 IEC 61000-4-4
    • Ip Degree Of Protection : IP67