Homeline All In One combination service entrance device, ringed socket, no bypass, OH, 100 A, 10 kA, 10 spaces

ALL-IN-ONE RING TYPE SURFACE O

SQDSO1020M100S SO1020M100S 785901328049
376.49 / EACH
  • Certifications: UL
  • Depth: 4.56 in
  • Height: 20.79 in
  • Line Rated Current: 100 A
  • Mounting Type: Surface
  • Number of Circuits: 20
  • Short Circuit Current: 10 kA
  • Warranty Length: 18 mth
  • Width: 13.46 in
Homeline All In One combination service entrance devices are available with ring or ringless type meter socket designs. Devices have factory installed service disconnect(s) in most cases. Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. These Homeline combination service entrance devices meet the Federal Specification W-P-115c as Type 1, Class 2 specifications. This Homeline All In One combination service entrance device has a ringed meter socket with no bypass. This unit can be feed from an overhead service. The service disconnect is a HOM2100 with a maximum rating of 100 A. Device has a 10 kA short circuit current rating. Load center has 10 spaces which will accept up to 10 tandem Homeline circuit breakers. This unit has a NEMA 3R surface mount enclosure that is 20.79 inches tall, 13.46 inches wide and 4.56 inches deep. The line side lugs will accept 6 AWG to 1 AWG copper or aluminum wire. The service ground lug will accept 8 AWG to 4 AWG copper or aluminum wire. This Homeline All In One combination service entrance meter main unit is UL Listed.
  • Product Description
  • Specifications
Homeline All In One combination service entrance devices are available with ring or ringless type meter socket designs. Devices have factory installed service disconnect(s) in most cases. Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. These Homeline combination service entrance devices meet the Federal Specification W-P-115c as Type 1, Class 2 specifications. This Homeline All In One combination service entrance device has a ringed meter socket with no bypass. This unit can be feed from an overhead service. The service disconnect is a HOM2100 with a maximum rating of 100 A. Device has a 10 kA short circuit current rating. Load center has 10 spaces which will accept up to 10 tandem Homeline circuit breakers. This unit has a NEMA 3R surface mount enclosure that is 20.79 inches tall, 13.46 inches wide and 4.56 inches deep. The line side lugs will accept 6 AWG to 1 AWG copper or aluminum wire. The service ground lug will accept 8 AWG to 4 AWG copper or aluminum wire. This Homeline All In One combination service entrance meter main unit is UL Listed.
  • Environment
    • Product Certifications : UL Listed
    • Nema Degree Of Protection : NEMA 3R
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Line Rated Current : 100 A
    • Electrical Connection : lugs line side || lugs service ground
    • Height : 20.79 in
    • Branch Circuit Breaker Rated Current : 80 A
    • Awg Gauge : AWG 6...AWG 1 aluminium/copper)line side || AWG 8...AWG 4 aluminium/copper)service ground
    • Depth : 4.56 in
    • Device Mounting : surface
    • Width : 13.46 in
    • Service Feed Location : OH
    • Device Composition : service disconnect (factory installed)
    • Number Of Spaces : 10
    • Short-Circuit Current : 10 kA
    • Service Disconnect Rated Current : 100 A
    • Number Of Tandem Circuit Breakers : 10
    • Tightening Torque : main lugs 50 lb.in, AWG 6...AWG 1, aluminium/copper || branch lugs 35 lb.in, AWG 6...AWG 4, aluminium/copper || branch lugs 25 lb.in, AWG 8, aluminium/copper || branch lugs 20 lb.in, AWG 14...AWG 10, aluminium/copper || branch lugs 20 lb.in, AWG 12...AWG 10, aluminium/copper || Cover 10 lb.in
    • Bypass Type : no bypass
    • Number Of Circuits : 20
  • Hub Type : A
  • Product Or Component Type : All-In-One
  • Meter Socket Type : ringed
  • Range Of Product : Homeline
  • Offer Sustainability
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Reach Free Of Svhc : Yes
    • Rohs Exemption Information : Yes
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Mercury Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Eu Rohs Directive : Compliant