3-phase control relay, Harmony Control Relays, 8A, 2CO, overfrequency and underfrequency, 208...480V AC

3-phase control relay, Harmony Control Relays, 8A, 2CO, overfrequency and underfrequency, 208...480V AC

SQDRMNF22TB30 RMNF22TB30 3606489591120
125.16 / EA
http://schema.org/OutOfStock
  • Country of Origin: Indonesia
This 3-phase control relay belongs to the Schneider Electric Harmony Control relays range. This 3-phase control relay is integrated with NFC technology which brings in digital operation instead of analog operation. This is a 8A multifunction 3-phase control relay which monitors 3-phase or 3-phase with Neutral network and has an adjustable time delay of 0.1s to 60min. With Harmony NFC App, different alarms can be combined using AND, OR and NOT logic to form unique monitoring combinations for the two relay outputs which are individually configurable. NFC 3-phase control relay is a single reference supporting 7 functions namely Phase loss, Phase sequence, Asymmetry, Undervoltage, Overvoltage, Under-frequency, and Over-frequency. The 3-phase control relay is IP20 (terminals), IP40 (housing), and IP40(front panel) protected. Furthermore, the 4 digit password enhances security by preventing unauthorized change of settings. This RMNF22 dimensions are 22.5mm (width) x 90mm (height) x 99mm (depth) and weighs 0.125Kg. 0 0 It conforms to international standard EN/IEC 60255-1 and certifications like UL, CSA, CE, CCC, EAC, and RCM. 0 It is sold as a single unit. 0 Monitoring and testing are now intuitive as exact fault conditions can be identified through front LEDs and analyze data with Harmony NFC App. This saves time and boosts efficiency. 0 0 0 0 0
QTY
  • Product Description
  • Features
  • Specifications
This 3-phase control relay belongs to the Schneider Electric Harmony Control relays range. This 3-phase control relay is integrated with NFC technology which brings in digital operation instead of analog operation. This is a 8A multifunction 3-phase control relay which monitors 3-phase or 3-phase with Neutral network and has an adjustable time delay of 0.1s to 60min. With Harmony NFC App, different alarms can be combined using AND, OR and NOT logic to form unique monitoring combinations for the two relay outputs which are individually configurable. NFC 3-phase control relay is a single reference supporting 7 functions namely Phase loss, Phase sequence, Asymmetry, Undervoltage, Overvoltage, Under-frequency, and Over-frequency. The 3-phase control relay is IP20 (terminals), IP40 (housing), and IP40(front panel) protected. Furthermore, the 4 digit password enhances security by preventing unauthorized change of settings. This RMNF22 dimensions are 22.5mm (width) x 90mm (height) x 99mm (depth) and weighs 0.125Kg. 0 0 It conforms to international standard EN/IEC 60255-1 and certifications like UL, CSA, CE, CCC, EAC, and RCM. 0 It is sold as a single unit. 0 Monitoring and testing are now intuitive as exact fault conditions can be identified through front LEDs and analyze data with Harmony NFC App. This saves time and boosts efficiency. 0 0 0 0 0
  • Insulation Resistance
    • > 100 MOhm 500 V DC IEC 60255-27
  • US Rated Supply Voltage
    • 208...480 V AC 50/60 Hz, non self-powered
    • 120...277 V AC 50/60 Hz, non self-powered
  • Connections Terminals
    • screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
    • screw terminals, 2 x 0.5...2 x 1.5 mm² AWG 20...AWG 16) flexible with cable end
    • screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
    • screw terminals, 1 x 0.5...1 x 2.5 mm² AWG 20...AWG 14) flexible with cable end
  • Overvoltage Category
    • III conforming to IEC 60664-1
    • III conforming to UL 508
  • Mounting Support
    • 35 mm DIN rail conforming to IEC 60715
  • Supply Voltage Limits
    • 166.4-576 V AC line to line
    • 96-332.4 V AC line to neutral
  • IP Degree Of Protection
    • IP20 IEC 60529 terminals)
    • IP40 IEC 60529 housing)
    • IP40 IEC 60529 front panel)
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Carbon Footprint Of The Installation Phase A5
    • 0 kg CO2 eq.
    • 0.0006785287
  • Carbon Footprint Of The End Of Life Phase C1 To C4
    • 0.0790258909
    • 0.1 kg CO2 eq.
  • Maximum Switching Voltage
    • 250 V AC
  • Dielectric Test Voltage
    • 2.5 kV AC 50 Hz, 1 min IEC 60255-27
  • Maximum Measuring Cycle
    • 150 ms measurement cycle as true rms value
  • Carbon Footprint Of The Manufacturing Phase A1 To A3
    • 3 kg CO2 eq.
    • 2.7954181818
  • Maximum Switching Current
    • 8 A AC
  • Time Delay Type
    • adjustable 0.1 s...1 min Tt- time delay upon fault
  • Measurement Range
    • 208...480 V AC
  • Reset Time
    • 1500 ms at maximum voltage
  • Vibration Resistance
    • 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6
    • 1 gn 58.1-150 Hz) not in operation IEC 60068-2-6
    • 0.035 mm 10-58.1 Hz) in operation IEC 60068-2-6
    • 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
  • Market Segmentation
    • Commercial
    • Industrial
  • Persona Type Names
    • Charge Point Operator
    • End User
    • Contractor
    • Original Equipment Manufacturer
    • OEM - Control Panelbuilder
    • Panel Builder
    • Electrician
    • System Integrator
    • IT Channel Partner
  • Measurement Error
    • < 0.05 %/Hz with frequency variation
    • < 0.05 %/°C with temperature variation
  • Power Consumption In VA
    • 4-4 VA 480 V AC 60 Hz
  • Carbon Footprint Of The Use Phase B2 B3 B4 B6
    • 55 kg CO2 eq.
    • 54.9367466667
  • Electromagnetic Compatibility
    • voltage dips and interruptions immunity test - test level: 70 % (25/30 cycles) conforming to IEC 61000-4-11
    • electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
    • radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
    • immunity for industrial environments conforming to IEC 61000-6-2
    • 1 MHz damped oscillating wave - test level: 2.5 kV CM, 1 kV DM criteria B conforming to IEC 61000-4-18
    • voltage dips and interruptions immunity test - test level: 0 % (0.5...25 cycles) conforming to IEC 61000-4-11
    • magnetic field at power frequency - test level: 30 A/m (continuous)-300 A/m (1-3 s) level 4 conforming to IEC 61000-4-8
    • surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
    • immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1
    • voltage dips and interruptions immunity test - test level: 40 % (10/12 cycles) conforming to IEC 61000-4-11
    • voltage interruptions - test level: 0 % criteria C (250/300 cycles) conforming to IEC 61000-4-29
    • electrical fast transient/burst immunity test - test level: 4 kV criteria B (direct) conforming to IEC 61000-4-4
    • emission standard for industrial environments conforming to IEC 61000-6-4
    • surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
    • electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
    • conducted RF disturbances level 3 conforming to IEC 61000-4-6
  • Supply Frequency
    • 50...60 Hz +/- 10 %
  • Hysteresis
    • 3-3 % fixed phase failure detection
  • Relative Humidity
    • 93-97 % 25-55 °C IEC 60068-2-30
  • Directives
    • 2014/30/EU - electromagnetic compatibility
    • 2014/35/EU - low voltage directive
    • 2014/53/EU - radio equipment directive
  • Persona Type Ids
    • BM9
    • EU
    • LC
    • OM
    • OM8
    • PB
    • SC
    • SI
    • VR
  • Setting Accuracy Of Time Delay
    • +/- 3 % 10 s...60 min
    • +/- 300 ms 0...10 s
  • Relay Monitored Parameters
    • phase sequence
    • phase failure detection
    • overvoltage detection
    • undervoltage detection
    • overfrequency and underfrequency
    • asymmetry
  • Carbon Footprint Of The Distribution Phase A4
    • 0.0175464727
    • 0 kg CO2 eq.
  • Tightening Torque
    • 0.6-1 N.m IEC 60947-1
    • 5.3-8.8 lbf.in IEC 60947-1
  • Minimum Switching Current
    • 100 mA 6 V
  • Operating System
    • Androidversion >= V7.0
    • iOSversion >= V14.5
  • Repeat Accuracy
    • +/- 0.5 % input circuit
    • +/- 3 % time delay
  • Utilisation Category
    • AC-15 IEC 60947-5-1
    • DC-13 IEC 60947-5-1
    • AC-1 IEC 60947-4-1
    • DC-1 IEC 60947-4-1
  • Market Segmentation Id
    • COMMERCIAL
    • INDUSTRIAL
  • Shock Resistance
    • 15 gn 11 ms) not in operation IEC 60068-2-27
    • 5 gn 11 ms) in operation IEC 60068-2-27
  • Alarm Threshold
    • 166...576 V adjustable overvoltage and undervoltage detection (line to line);
    • 96...332 V adjustable overvoltage and undervoltage detection (line to neutral);
    • 5...150 V adjustable asymmetry;
    • 45...66 Hz adjustable overfrequency or underfrequency;
  • Local Signalling
    • Un, green LED steady)power ON
    • R1, amber LED steady)relay energised
    • R1, amber LED blinking)timing in progress
    • R2, amber LED steady)relay energised
    • R2, amber LED blinking)timing in progress
    • PL, red LED steady)alarm phase failure triggered
    • PS, red LED blinking)alarm phase sequence failure triggered
    • UV, red LED steady)alarm undervoltage failure triggered
    • OV, red LED blinking)alarm overvoltage failure triggered
    • UF, red LED steady)alarm underfrequency failure triggered
    • OF, red LED blinking)alarm overfrequency failure triggered
    • ASYM, red LED steady)alarm asymmentry failure triggered
  • Software Designation
    • Ecostruxure Industrial Device downloadable from Google Play store or Apple Store)
  • UIMP Rated Impulse Withstand Voltage
    • 4 kV 1.2/50 µs
  • Assets
    • CAD : https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001782_3D-CAD
  • Complementary Attributes
    • UI Rated Insulation Voltage : 400 V
  • Important Information Attributes
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-07
    • Manufacturing Carbon Footprint : 2.7954181818
    • Distribution Carbon Footprint : 0.0175464727
    • Installation Carbon Footprint : 0.0006785287
    • Use Carbon Footprint : 54.9367466667
    • End Of Life Carbon Footprint : 0.0790258909
    • Legacy WEEE Scope : In
    • WEEE Product Category : 5
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2506028EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Conformity Date : 1930
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : Yes
    • China ROHS Label : 5
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Adjustment Of Asymmetry Threshold : 2...20 % of Un selected
    • Housing Material : self-extinguishing plastic
    • Immunity To Microbreaks : 10 ms
    • On Load Factor : 100 %
    • Package Weight Lbs : 138.000 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : NFC control relay
    • Range Of Product : Harmony Control Relays
    • Relay Name : RMNF22
    • Response Time : <= 300 ms
    • Returnability : Yes
    • Setting Accuracy Of The Switching Threshold : +/- (1.5 % + 1 V)
    • Sustainable Packaging : Yes
    • Threshold Adjustment Voltage : 2...20 % of Un selected
    • Total Lifecycle Carbon Footprint : 58 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Carbon Footprint Kg Co2 Eq Total Life Cycle : 57.8294157408
    • Relationship Type : cross-selling relationship
    • Pep Code : ENVPEP2506028EN
    • Pep Verification Date : 2019-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Product Weight In G : 136
    • Functional Unit Description : To switch ON/OFF electrical contacts when the abnormal operating conditions is detected during 10 years and a 100% use rate.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unité (unit)
    • Reference Lifetime In Y : 10
    • Energy Consumption On Product Lifetime In Kwh : 112.128
    • Nbr Of Units In Pkg : 1
    • Warranty In Months : 18
    • Energy Model Manufacturing A1 A3 : Energy model used: Indonesia
    • Energy Model Installation A5 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model Use B6 : Electricity mix; AC; < 1kV; EU-27
    • Energy Model End Of Life C1 C4 : Electricity mix; AC; < 1kV; EU-27
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.0008834458
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.0008786713
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.0000000007
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.0000047734
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000000005
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 652.2027735733
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 28.1717818182
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 0.2465185455
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 0.0087966036
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 623.5733333333
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 0.2023432727
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0.0000396346
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0.0000037257
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0.0000359089
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 3.77244846
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 3.4780145455
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.0000000333
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.0286404267
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.2657934545
    • Materials For Energy Recovery Kg Total Life Cycle : 0.0207956496
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0.0000000133
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0.0207956364
    • Materials For Recycling Kg Total Life Cycle : 0.0524594036
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.0097479855
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0.0124736727
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.0302377455
    • Net Use Of Fresh Water M3 Total Life Cycle : 199.2093117897
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.0156684364
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0000015704
    • Net Use Of Fresh Water M3 Installation A5 : 0.0000000742
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 199.1936
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.0000417087
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 205.6284845482
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 0.8014850909
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0006234487
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.0000921017
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 204.8256
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.0006839069
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.0000038783
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.0000002967
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.0000035788
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.0000000027
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.1372902098
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0004903295
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.000000444
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000000181
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.1367978667
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.0000015515
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 994.3020889964
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 36.1018181818
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.2477672727
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0088475418
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 957.696
    • Total Use Of Non Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.247656
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 1134.8451442982
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 37.1242909091
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 0.2481010909
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 0.0088613891
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 1097.216
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 0.2478909091
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 140.542957074
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 1.0223738182
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0003306407
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.000013762
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 139.52
    • Total Use Of Renewable Primary Energy Resources Primary Energy And Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0002388531
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 2.2815854545
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 2.2815854545
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 992.0209980873
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 33.8207272727
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.2477672727
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.0088475418
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 957.696
    • Use Of Non Renewable Primary Energy Excluding Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.247656
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 0.2470996364
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.2470996364
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 140.295845074
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 0.7752618182
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0.0003306407
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0.000013762
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj Operational Energy Use B6 : 139.52
    • Use Of Renewable Primary Energy Excluding Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0.0002388531
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.0007982087
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.0007982087
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Air Pollution M3 Total Life Cycle : 2696.6694976242
    • Air Pollution M3 Manufacturing A1 A3 : 329.5898181818
    • Air Pollution M3 Distribution A4 : 0.7464421818
    • Air Pollution M3 Installation A5 : 0.0270602909
    • Air Pollution M3 Operational Energy Use B6 : 2364.5013333333
    • Air Pollution M3 End Of Life C1 C4 : 1.8048436364
    • Water Pollution M3 Total Life Cycle : 2573.5607789091
    • Water Pollution M3 Manufacturing A1 A3 : 300.1149090909
    • Water Pollution M3 Distribution A4 : 2.8855490909
    • Water Pollution M3 Installation A5 : 0.1029025455
    • Water Pollution M3 Operational Energy Use B6 : 2266.88
    • Water Pollution M3 End Of Life C1 C4 : 3.5774181818
    • Acidification Of Soil And Water Kg Equivalent So2 Total Life Cycle : 0.2367071662
    • Photochemical Ozone Formation Kg Equivalent C2h4 Total Life Cycle : 0.0132709302
    • Water Eutrophication Kg Equivalent P04 3 Total Life Cycle : 0.0168774244
    • Acidification Of Soil And Water Kg Equivalent So2 Manufacturing A1 A3 : 0.0074131127
    • Acidification Of Soil And Water Kg Equivalent So2 Distribution A4 : 0.0000801176
    • Acidification Of Soil And Water Kg Equivalent So2 Installation A5 : 0.0000028272
    • Acidification Of Soil And Water Kg Equivalent So2 Operational Energy Use B6 : 0.2291541333
    • Acidification Of Soil And Water Kg Equivalent So2 End Of Life C1 C4 : 0.0000569753
    • Global Warming Kg Equivalent Co2 Total Life Cycle : 57.8294157408
    • Global Warming Kg Equivalent Co2 Manufacturing A1 A3 : 2.7954181818
    • Global Warming Kg Equivalent Co2 Distribution A4 : 0.0175464727
    • Global Warming Kg Equivalent Co2 Installation A5 : 0.0006785287
    • Global Warming Kg Equivalent Co2 Operational Energy Use B6 : 54.9367466667
    • Global Warming Kg Equivalent Co2 End Of Life C1 C4 : 0.0790258909
    • Photochemical Ozone Formation Kg Equivalent C2h4 Manufacturing A1 A3 : 0.0006682916
    • Photochemical Ozone Formation Kg Equivalent C2h4 Distribution A4 : 0.0000057172
    • Photochemical Ozone Formation Kg Equivalent C2h4 Installation A5 : 0.0000002113
    • Photochemical Ozone Formation Kg Equivalent C2h4 Operational Energy Use B6 : 0.0125917867
    • Photochemical Ozone Formation Kg Equivalent C2h4 End Of Life C1 C4 : 0.0000049234
    • Water Eutrophication Kg Equivalent P04 3 Manufacturing A1 A3 : 0.00299608
    • Water Eutrophication Kg Equivalent P04 3 Distribution A4 : 0.0000184527
    • Water Eutrophication Kg Equivalent P04 3 Installation A5 : 0.0000006871
    • Water Eutrophication Kg Equivalent P04 3 Operational Energy Use B6 : 0.0138359467
    • Water Eutrophication Kg Equivalent P04 3 End Of Life C1 C4 : 0.0000262579
  • General Attributes
    • Product Or Component Type : NFC control relay
    • Range Of Product : Harmony Control Relays
  • Output Attributes
    • Output Contacts : 2 C/O
  • Environment Attributes
    • ROHS Exemption Information : Yes
    • China ROHS url : https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfRoHSChina&pid=484775256&lang=en-us
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 57.8294157408
    • Ambient Air Temperature For Operation : -20-60 °C
    • Circularity Profile : ENVEOLI2506028EN
    • Environmental Disclosure : ENVPEP2506028EN
    • EU ROHS Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2506028EN
    • Pep Verification Date : 2019-05-01
    • PCR Version : PCR-ed3-EN-2015 04 02
    • PSR Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • Specifications
    • Country of Origin : Indonesia