Generator panel, QO, 1 phase, 18 spaces, 36 circuits, 30A main breaker, PoN, NEMA1, cover with door

Generator panel, QO, 1 phase,

SQDQOGP3P3036P QOGP3P3036P 785901666967
455.00 / EA
http://schema.org/OutOfStock
  • Country of Origin: USA
  • Depth: 95 mm
  • Height: 455 mm
  • Number of Circuits: 36
  • Short Circuit Current Rating: 10 kA
  • Width: 362 mm
QO Load Centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO Load Centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO Load Centers feature plated copper bus, providing superior performance and durability. This QO Generator Panel contains a main breaker and is rated at 30 A and 1 phase. This system provides 18 spaces in a NEMA 1 enclosure and it is Plug-on neutral load center. CQO load centers are CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
QO Load Centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO Load Centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO Load Centers feature plated copper bus, providing superior performance and durability. This QO Generator Panel contains a main breaker and is rated at 30 A and 1 phase. This system provides 18 spaces in a NEMA 1 enclosure and it is Plug-on neutral load center. CQO load centers are CSA certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Specifications
    • Country of Origin : United States
    • Width : 362 mm
    • Height : 455 mm
    • Range Of Product : QO
    • Product Or Component Type : panel
  • Complementary
    • Height : 455 mm
    • Phase : 1 phase
    • Tightening Torque : Cover 20 lb.in
    • [Ue] Rated Operational Voltage : 120/240 V AC
    • Number Of Circuits : 36
    • Short-Circuit Current : 10 kA
    • Line Rated Current : 30 A
    • Width : 362 mm
    • Depth : 95 mm
    • Load Center Type : PoN Convertible Mains (breaker)
    • Device Composition : grounding bar (ordered separately)
  • Environment
    • Product Certifications : UL Listed
    • Ambient Air Temperature For Operation : -5 °C || 40 °C
    • Nema Degree Of Protection : NEMA 1 indoor enclosure
  • Environmental data
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP2212001
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Circularity Profile : N/A
    • Take-Back : No
    • Eu Rohs Directive : Compliant with Exemptions