Residual current protection relay, Vigirex RH10M, 1A, 120VAC, DIN rail mounting

GROUND FAULT RELAY RH10M 1A IN

SQD56327 56327 785901906278
1951.17 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
The purpose of ground-fault protection is to measure the ground leakage current of an electrical installation, or part of an installation, and interrupt the power supply if the ground-fault current becomes dangerous to property. Vigirex™ ground-fault relays, with associated sensors (current transformers), measure the leakage current in an electrical installation to detect levels that may be damaging. When used for protection, they cause an associated circuit breaker or switch to interrupt the supply of power to the protected system. They may also be used for monitoring only, with output to an alarm. The Vigirex product line can be used with loads up to 3200A. It includes fixed sensitivities from 30 mA to 1 A and adjustable sensitivities up to 30 A, providing a solution that offers both flexibility and performance. The responsiveness of the Vigirex relay is determined from a combination of their sensitivity (measured in milliamperes or amps) and their time delays (duration that the threshold of ground-fault is exceeded). These can range from instantaneous (no intentional delay) to 4.5 seconds. The shortest delay will provide the greatest protection, while the longest will minimize nuisance tripping. The range of time delays is also helpful when providing a coordinated ground-fault protection scheme. This Vigirex, time delay switch is DIN rail mounted. This product has a control current voltage of 120 VAC. This product complys to UL standards.
QTY
  • Features
  • Specifications
  • Features
    • Vigirex relays ensure coordination with ComPacT circuit breakers (switch off within 40ms)
    • Continuous monitoring of the power supply, the relay/toroid link and internal electronics
    • Reinforced insulation of Vigirex relays (overvoltage category IV)
    • Access to settings protected by a lead-sealable cover or password
    • Enhanced sustainability with Environmental Data program
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Standards : UL 1053
  • Important Information Attributes
    • Persona Type Ids : LC, PB
    • Persona Type Names : Contractor, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Carbon Footprint Of The Distribution Phase A4 : 0.03752979110943371, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.5 kg CO2 eq., 0.5027833478282274
    • Carbon Footprint Of The Installation Phase A5 : 0.07023237229451437, 0.1 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 24 kg CO2 eq., 23.928832805500406
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 43 kg CO2 eq., 42.72599999999999
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • WEEE Applicability : Finished product
    • WEEE Scope : In
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2310022EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Circuit Breaker Type : standard
    • Control Type : manual reset
    • Earth Leakage Protection Time Delay : instantaneous
    • Earth Leakage Sensitivity : 1 A
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Product contains halogen above thresholds
    • Mounting Support : DIN rail
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Range Of Product : Vigirex
    • Returnability : No
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 67 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ue Rated Operational Voltage2 : 130 V AC
    • Medium Desc : Residual current protection relay, Vigirex RH10M, 1A, 120VAC, DIN rail mounting
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP2310022EN
    • Database Version : 2022-01
    • Pep Verification Date : 2023-12-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Protect during 10 years people and premises at risk of fire or explosion with assigned voltage 220-240V by detecting and measuring the earth leakage current with sensitivity 0.3-30A.
    • Functional Unit Unit : Unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model Installation A5 2 : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model Use B6 2 : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Production mix; Low voltage; UE-27
    • Global Commercial Status : Commercialised
    • Ue Rated Operational Voltage5 : 130 V AC
  • Environment Attributes Main
    • Take Back : No, Nej
    • China ROHS Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • EU ROHS Directive : Compliant By Exemption , Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Halogene Performance : Product contains halogen above thresholds
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 67.26537831673258
    • Circularity Profile : ENVEOLI2310022EN
    • Environmental Disclosure : ENVPEP2310022EN
    • Halogen Content Performance : Product contains halogen above thresholds
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2310022EN
    • Pep Verification Date : 2023-12-05
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Range Of Product : Vigirex
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months