  • Depth: 120 mm
  • Number of Outputs: 0
This safety relay is designed for monitoring Emergency stop and Guard switch. The safety relay is powered with 24V AC/DC, and equipped with a spring removable terminal block. This basic safety modules embeds pre-defined safety functions. This safety relay embeds 1 control output, 4 NO safety outputs, and 2 NC diagnostic outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÜV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Basic offers the most optimised solution for applications with hardwired safety modules.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=XPSBAC14AC_3D-simpl, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_3D-simplified.stp, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-back.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-back.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-bottom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-bottom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-front.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-front.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-isometric.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-isometric.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-left.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-left.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-right.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-right.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-top.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005504_3D-CAD&p_File_name=MCADID0005504_2D-top.dxf
  • Conformance Attributes
    • Product Certifications : TÜV, cULus
    • Standards : IEC 60947-5-1, IEC 61508-1 functional safety standard, IEC 61508-2 functional safety standard, IEC 61508-3 functional safety standard, IEC 61508-4 functional safety standard, IEC 61508-5 functional safety standard, IEC 61508-6 functional safety standard, IEC 61508-7 functional safety standard, ISO 13849-1 functional safety standard, IEC 62061 functional safety standard
  • Complementary Attributes
    • Ie Rated Operational Current : 3 A DC-1 for normally closed relay contact, 1 A DC-13 for normally closed relay contact, 5 A AC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A DC-13 for normally open relay contact, 3 A AC-1 for normally closed relay contact, 1 A AC-15 for normally closed relay contact
    • Us Rated Supply Voltage : 24 V AC - 15...10 %, 24 V DC - 20...20 %
    • Minimum Output Current : 10 mA relay output
    • Minimum Output Voltage : 5 V relay output
    • Ui Rated Insulation Voltage : 300 V 2)IEC 60947-1
    • Uimp Rated Impulse Withstand Voltage : 4 kV II IEC 60947-1
  • Important Information Attributes
    • Persona Type Ids : EU, OM, OM8
    • Persona Type Names : End User, Original Equipment Manufacturer, OEM - Control Panelbuilder
    • Function Of Module : emergency stop button with 2 NC contacts, guard monitoring with 1 or 2 limit switches
    • Local Signalling : LED green power power ON, LED red error error, LED yellow state status, LED yellow start1 start input, LED yellow start2 start input
    • Response Time : 150 ms at 24 V AC, 80 ms at 24 V DC
    • Safety Level : can reach PL e/category 4 for normally open relay contact ISO 13849-1, can reach SILCL 3 for normally open relay contact IEC 62061, can reach SIL 3 for normally open relay contact IEC 61508, can reach PL c/category 1 for normally closed relay contact ISO 13849-1, can reach SILCL 1 for normally closed relay contact IEC 62061, can reach SIL 1 for normally closed relay contact IEC 61508
    • Safety Reliability Data : PFHd = 0.95E-09 for normally open relay contact IEC 62061, PFHd = 0.95E-09 for normally open relay contact IEC 61508-1, SFF > 99% for normally open relay contact IEC 61508-1, PFHd = 0.95E-09 for normally closed relay contact ISO 13849-1, PFHd = 0.95E-09 for normally closed relay contact IEC 62061, HFT=0 for normally closed relay contact IEC 61508-1, PFHd = 0.95E-09 for normally closed relay contact IEC 61508-1, SFF > 60% for normally closed relay contact IEC 61508-1, type = B for normally closed relay contact IEC 61508-1, MTTFd > 30 years for normally open relay contact ISO 13849-1, Dcavg >= 99 % for normally open relay contact ISO 13849-1, PFHd = 0.95E-09 for normally open relay contact ISO 13849-1, HFT = 1 for normally open relay contact IEC 62061, SFF > 99% for normally open relay contact IEC 62061, HFT = 1 for normally open relay contact IEC 61508-1, type = B for normally open relay contact IEC 61508-1, MTTFd > 30 years for normally closed relay contact ISO 13849-1, DC > 60 % for normally closed relay contact ISO 13849-1, HFT=0 for normally closed relay contact IEC 62061, SFF > 60% for normally closed relay contact IEC 62061
    • Connections Terminals : removable spring terminal block, 0.2...2.5 mm² solid or flexible, removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor, removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor, removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel, removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
    • Ie Rated Operational Current : 3 A DC-1 for normally closed relay contact, 1 A DC-13 for normally closed relay contact, 5 A AC-1 for normally open relay contact, 3 A AC-15 for normally open relay contact, 5 A DC-1 for normally open relay contact, 3 A DC-13 for normally open relay contact, 3 A AC-1 for normally closed relay contact, 1 A AC-15 for normally closed relay contact
    • Carbon Footprint Of The Distribution Phase A4 : 0.13969377603029492, 0.1 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.7 kg CO2 eq., 0.658013265948001
    • Carbon Footprint Of The Installation Phase A5 : 0.010761674675427399, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 5 kg CO2 eq., 5.342949163553912
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 48 kg CO2 eq., 48.426620565160576
    • Medium Desc : safety module, Harmony XPS, estop or guard, connected to supply terminals 24V AC or DC , no inputs, spring
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-01-12
    • Global Commercial Status : Commercialised
    • Pre Comm Date : 2021-05-03
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : PLC System - PLC Component
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : IDIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1811003EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : No
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : Yes
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : INDUSTRIAL
    • Market Segmentation : Industrial
    • Product Kit Identifier : N
    • Associated Fuse Rating : 10 A gG NO relay output circuit IEC 60947-1
    • Electrical Circuit Type : NC pair
    • Mounting Support : 35 mm symmetrical DIN rail
    • Power Consumption In Va : 3.5 VA 24 V AC 50/60 Hz
    • Power Consumption In W : 1.5 W 24 V DC
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : safety module
    • Range Of Product : Harmony Safety Automation
    • Returnability : No
    • Safety Module Application : for emergency stop and protective guard applications
    • Safety Module Name : XPSBAC
    • Software Version : v6.2.2
    • Sustainable Packaging : No
    • Terminal Identifier : power supply
    • Total Lifecycle Carbon Footprint : 55 kg CO2 eq.
    • Type Of Start : automatic/manual/monitored
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 6 A
    • Pep Code : ENVPEP1811003EN
    • Database Version : 2023-02
    • Pep Verification Date : 2024-11-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : To monitor signals from a variety of different sensors/devices for safety-related interruption of safety-related electrical circuits at 100% for 10 years.
    • Functional Unit Unit : Unit
    • Energy Model Manufacturing A1 A3 2 : Indonesia, ID
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; Italy, IT
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; Italy, IT
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; Italy, IT
    • Height Nominal : 100 mm
    • Width Nominal : 22.5 mm
  • Environment Attributes Main
    • Ip Degree Of Protection : IP20 terminals)IEC 60529, IP40 housing)IEC 60529, IP54 mounting area)IEC 60529
    • Take Back : Nej
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 54.57803844536821
    • Ambient Air Temperature For Operation : -25-55 °C
    • Circularity Profile : ENVEOLI1811003EN
    • Environmental Disclosure : ENVPEP1811003EN
    • Eu Rohs Directive : Compliant By Exemption
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 % non-condensing
    • Pep Code : ENVPEP1811003EN
    • Pep Verification Date : 2024-11-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : safety module
    • Range Of Product : Harmony Safety Automation
  • ETIM
    • ETIM 8 : EC001449
    • ETIM 9 : EC001449
  • Output Attributes
    • Minimum Output Current : 10 mA relay output
    • Minimum Output Voltage : 5 V relay output
    • Number Of Outputs : 0
  • Input Attributes
    • Input Compatibility : normally closed circuit ISO 14119, XC limit switch ISO 14119, mechanical contact ISO 14119, normally closed circuit ISO 13850
    • Input Protection Type : internal, electronic
    • Number Of Inputs : 0
    • Synchronisation Time Between Inputs : unlimited
  • Specifications
    • Depth : 120 mm