Power Relays, Harmony 9A, SPDT, 30A, flanged panel mount, sealed, 120V AC

ELECTROMECHNICAL POWER RELAYS,

SQD9AS7A120 9AS7A120 3606489915322
14.97 / EA
http://schema.org/OutOfStock
  • Depth: 27.8 mm
  • Dielectric Strength: 1500 V, 2500 V
  • Operating Position: Any Position
This 9AS7A120 power relay belongs to the Schneider Electric Harmony electromechanical relays range. 9A power relay has a sealed cover and is flanged panel mounting. It’s a 30A, 1 NO contact configuration mechanical relay with nominal coil voltage of 120V AC and coil resistance It conforms to international standard and certifications.
QTY
  • Product Description
  • Features
  • Specifications
This 9AS7A120 power relay belongs to the Schneider Electric Harmony electromechanical relays range. 9A power relay has a sealed cover and is flanged panel mounting. It’s a 30A, 1 NO contact configuration mechanical relay with nominal coil voltage of 120V AC and coil resistance It conforms to international standard and certifications.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=MCADID0005653_3D-simplified.stp, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-back.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-back.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-bottom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-bottom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-front.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-front.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-isometric.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-isometric.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-left.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-left.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-right.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-right.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-top.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0005653_3D-CAD&p_File_name=mcadid0005653_3d-simplified_2D-top.dxf
  • Conformance Attributes
    • Product Certifications : UL
    • Standards : UL 60947-4-1
  • Complementary Attributes
    • Maximum Switching Voltage : 277 V AC, 28 V DC
    • Minimum Switching Capacity : 5 W at 1 A, 5 V DC, 12 VA at 1 A, 12 V AC
    • Rated Power In Hp : 1 hp at 125 V AC, NO, 2 hp at 250 V AC, NO, 0.25 hp at 125 V AC, NC, 0.5 hp at 250 V AC, NC
    • Rated Power In Va : 470 VA at 240 V, NO on pilot duty, 275 VA at 240 V, NC on pilot duty
    • Ie Rated Operational Current : 30 A at 240 V AC-8a (NO) (full load), 30 A at 240 V AC-8a (NC) (locked rotor), 30 A at 240 V AC-1 (NO), 20 A at 240 V AC-1 (NC), 30 A at 28 V DC (NO) (on resistive load), 10 A at 28 V DC (NC) (on resistive load), 22 A at 120 V AC-8a (NO) (full load), 98 A at 120 V AC-8a (NO) (locked rotor), 80 A at 240 V AC-8a (NO) (locked rotor), 12 A at 240 V AC-8a (NC) (full load), 10 A at 277 V AC-8a (NC) (full load), 33 A at 277 V AC-8a (NC) (locked rotor), 10 A at 277 V AC-5a (NO) (ballast), 3 A at 277 V AC-5a (NC) (ballast)
    • Control Circuit Voltage Limits : 0.85...1.1 Uc
    • Uc Control Circuit Voltage : 120 V AC 50-60 Hz
    • Ui Rated Insulation Voltage : 320 V
    • Uimp Rated Impulse Withstand Voltage : 4 kV 1.2/50 µs
  • Important Information Attributes
    • Persona Type Ids : BM9, EU, LC, OM, OM8, PB, SC, SI, VR
    • Persona Type Names : Charge Point Operator, End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator, IT Channel Partner
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Dielectric Strength : 2500 V AC between coil and contact, 1500 V between contacts with micro disconnection
    • Drop Out Voltage Threshold : >= 0.2 Uc, >= 0.2 Uc
    • Electrical Durability : 30000 cycles for full load, 30 A at 240 V, AC-8a NO, 100000 cycles for resistive load, 10 A at 28 V, DC NC, 30000 cycles for full load, 10 A at 277 V, AC-8a NC, 1000 cycles for motor load NC, 100000 cycles, 30 A at 240 V, AC-1 NO, 50000 cycles for resistive load, 30 A at 28 V, DC NO, 30000 cycles for full load, 22 A at 120 V, AC-8a NO, 1000 cycles for motor load NO, 6000 cycles for ballast load, 10 A at 277 V, AC-5a NO, 100000 cycles, 20 A at 240 V, AC-1 NC, 30000 cycles for full load, 12 A at 240 V, AC-8a NC, 6000 cycles for ballast load, 3 A at 277 V, AC-5a NC
    • Shock Resistance : 10 gn operating, 100 gn not operating
    • Vibration Resistance : +/- 0.75 mm 10-55 Hz operating, +/- 0.75 mm 10-55 Hz operating, +/- 0.75 mm 10-55 Hz operating, +/- 0.75 mm 10-55 Hz not operating, +/- 0.75 mm 10-55 Hz not operating, +/- 0.75 mm 10-55 Hz not operating, +/- 0.75 mm 10-55 Hz operating, +/- 0.75 mm 10-55 Hz operating, +/- 0.75 mm 10-55 Hz operating, +/- 0.75 mm 10-55 Hz not operating
    • Connections Terminals : Faston terminals contact terminal AWG 12...AWG 10, connection size: 6.35 x 0.8 mm, Faston terminals coil terminal AWG 22...AWG 14, connection size: 4.8 x 0.5 mm
    • Ie Rated Operational Current : 30 A at 240 V AC-8a (NO) (full load), 30 A at 240 V AC-8a (NC) (locked rotor), 30 A at 240 V AC-1 (NO), 20 A at 240 V AC-1 (NC), 30 A at 28 V DC (NO) (on resistive load), 10 A at 28 V DC (NC) (on resistive load), 22 A at 120 V AC-8a (NO) (full load), 98 A at 120 V AC-8a (NO) (locked rotor), 80 A at 240 V AC-8a (NO) (locked rotor), 12 A at 240 V AC-8a (NC) (full load), 10 A at 277 V AC-8a (NC) (full load), 33 A at 277 V AC-8a (NC) (locked rotor), 10 A at 277 V AC-5a (NO) (ballast), 3 A at 277 V AC-5a (NC) (ballast)
    • Carbon Footprint Of The Distribution Phase A4 : 0.0041287423, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0 kg CO2 eq., 0.0040203711
    • Carbon Footprint Of The Installation Phase A5 : 0.0002499711, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.2 kg CO2 eq., 0.1599092784
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 51 kg CO2 eq., 51.19282
    • Medium Desc : Power Relays, Harmony 9A, SPDT, 30A, flanged panel mount, sealed, 120V AC
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-02-24
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : Y
    • Legacy Weee Scope : In
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2006003EN
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : Yes
    • Phenolic Free Solution : Yes
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Consumption : 2.6 VA
    • Average Resistance : 2500 Ohm at 23 °C +/- 10 %
    • Contacts Material : silver alloy contacts
    • Mechanical Durability : 10000000 cycles
    • Mounting Support : panel flange
    • Network Frequency : 50-60 Hz
    • Operating Position : any position
    • Operating Time : 20 ms
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : power relay
    • Protection Category : RT III
    • Range Of Product : Harmony
    • Reset Time : 10 ms
    • Returnability : Yes
    • Software Version : EIME v5.8.1
    • Sustainable Packaging : No
    • Switch Function : SPDT
    • Total Lifecycle Carbon Footprint : 51 kg CO2 eq.
    • Silicone Free : Yes
    • Pep Code : ENVPEP2006003EN
    • Database Version : 2016-11
    • Pep Verification Date : 2020-07-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Relays are used when a low-power signal is needed in order to control a circuit, or when a number of circuits need to be controlled by one signal.This relay uses a physical moving part to connect contacts within the output component of the relay. The movement of this contact is generated using electromagnetic forces from the low-power input signal, allowing the completion of the circuit that contains the high-power signal.The Power Relays are provided with 9A to offer robust performance in applications such as HVAC,motor controls, and alarm systems during 20 years with a 10% use rate, Input voltage range from 12 to 240 Vac and from 5 to 110 Vdc.
    • Functional Unit Unit : Unit
    • Energy Model Manufacturing A1 A3 2 : Energy model used: China
    • Energy Model Installation A5 2 : Electricity mix; AC; 120V; US
    • Energy Model Use B6 2 : Electricity mix; AC; 120V; US
    • Energy Model End Of Life C1 C4 2 : Electricity mix; AC; 120V; US
    • Height Nominal : 50 mm
    • Width Nominal : 27.3 mm
  • Environment Attributes Main
    • Take Back : Nej
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China Rohs Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Lead Free : Yes
    • Mercury Free : Yes
    • Silicon Free : Yes
    • Carbon Footprint : 51.3611283629
    • Ambient Air Temperature For Operation : -40-40 °C
    • Ambient Air Temperature For Storage : -40-85 °C
    • Circularity Profile : ENVEOLI2006003EN
    • Environmental Disclosure : ENVPEP2006003EN
    • Eu Rohs Directive : Compliant
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2006003EN
    • Pep Verification Date : 2020-07-01
    • Pcr Version : PCR-ed3-EN-2015 04 02
    • Psr Version : PSR-0005-ed2-EN-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : power relay
    • Range Of Product : Harmony
  • Input Attributes
    • Input Current : 30 A NO, 20 A NC
  • Specifications
    • Depth : 27.8 mm