IEC contactor,Easy TeSys DPE,nonreversing,38A,3P,20HP at 480V AC,240V 50/60Hz coil

IEC contactor,Easy TeSys DPE,nonreversing,38A,3P,20HP at 480V AC,240V 50/60Hz coil

SQDDPE38U7 DPE38U7 3606481063274
70.77 / EA
http://schema.org/OutOfStock
Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 38A/690V AC-3 (20 HP@480V). It provides a 240V AC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (UL, CSA,CE,CCC), Environmental compliant (RoHS/REACh).
QTY
  • Product Description
  • Features
  • Specifications
Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 38A/690V AC-3 (20 HP@480V). It provides a 240V AC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (UL, CSA,CE,CCC), Environmental compliant (RoHS/REACh).
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Important Information Attributes
    • Persona Type Ids : OM, OM8, PB, SC
    • Persona Type Names : Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : RESIDENTIAL, COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Residential, Commercial, Industrial
    • Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 2 for power circuit
    • Contactor Application : resistive load, motor control
    • Electrical Durability : 1 Mcycles 38 A AC-3 <= 440 V, 0.6 Mcycles 52 A AC-1 <= 440 V
    • Hold In Power Consumption In VA : 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C), 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
    • Inrush Power In VA : 70-70 VA 60 Hz cos phi 0.75 (at 20 °C), 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
    • Motor Power KW : 9 kW 220...230 V AC 50/60 Hz, 18.5 kW 380...400 V AC 50/60 Hz, 18.5 kW 415 V AC 50/60 Hz, 18.5 kW 440 V AC 50/60 Hz, 18.5 kW 500 V AC 50/60 Hz, 18.5 kW 660...690 V AC 50/60 Hz
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Power Dissipation Per Pole : 2 W AC-3, 5 W AC-1
    • Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm, power circuit 2.5 N.m screw clamp terminals Philips No 2
    • IE Rated Operational Current : 38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 52 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • ITH Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 50 A (at 60 °C) for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.17403709638325782, 0.2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.9 kg CO2 eq., 0.9082164355791604
    • Carbon Footprint Of The Installation Phase A5 : 0.02800187398370036, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 2 kg CO2 eq., 2.239971361958996
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 26 kg CO2 eq., 26.337997000091228
    • Connections Terminals : power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-08-12
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1501004
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Average Impedance : 2 mOhm - Ith 50 A 50 Hz for power circuit
    • Coil Technology : without built-in suppressor module
    • Device Short Name : DPE
    • Energy Efficiency Optimized : False
    • Fire Resistance : 850 °C IEC 60695-2-1
    • Flame Retardance : V1 conforming to UL 94
    • Heat Dissipation : 2-3 W 50/60 Hz
    • Package Weight Lbs : 421.841 g
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Protective Treatment : TH IEC 60068-2-30
    • Range : Easy TeSys
    • Returnability : Yes
    • Signalling Circuit Frequency : 25...400 Hz
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 30 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Auxiliaries : DPEAN11
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant​, Compliant
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 29.68822376799634
    • Circularity Profile : ENVEOLI1501004
    • Environmental Disclosure : ENVPEP1501004EN
    • IP Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...6561.68 ft (0...2000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1501004EN
    • Pep Verification Date : 2025-08-05
    • PCR Version : PCR-4-ed4-EN-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • Complementary Attributes
    • Control Circuit Voltage Limits : drop-out: 0.3...0.6 Uc at 50/60 Hz (at <70 °C), operational: 0.8...1.1 Uc at 50 Hz (at <60 °C), operational: 0.85...1.1 Uc at 60 Hz (at <60 °C), operational: 1...1.1 Uc at 50/60 Hz (at <70 °C)
    • IRMS Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947
    • Maximum Horse Power Rating : 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 20 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 25 hp at 575/600 V AC 50/60 Hz for 3 phase motors
    • IE Rated Operational Current : 38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 52 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Motor Phase Current : 38 A
    • Maximum Operating Rate : 3600 cyc/h 60 °C
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 550 A at 440 V for power circuit conforming to IEC 60947
    • UC Control Circuit Voltage : 240 V AC 50/60 Hz
    • UI Rated Insulation Voltage : power circuit 690 V IEC 60947-4-1
    • UIMP Rated Impulse Withstand Voltage : 6 kV IEC 60947
  • General Attributes
    • Product Or Component Type : contactor