Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5 HP@480V). It provides a 24V DC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (UL, CSA,CE,CCC), Environmental compliant (RoHS/REACh).
- Prop 65
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Complementary Attributes
- Control Circuit Voltage Limits : operational: 0.8...1.25 Uc (at <60 °C), operational: 1...1.25 Uc (at <70 °C), drop-out: 0.1...0.3 Uc (at <70 °C)
- Irms Rated Making Capacity : 250 A at 440 V for power circuit, 140 A AC for signalling circuit, 250 A DC for signalling circuit
- Maximum Horse Power Rating : 2 hp at 230...240 V AC 50/60 Hz for 3 phase motors0.33 hp at 115 V AC 50/60 Hz for 1 phase motors, 1 hp at 230...240 V AC 50/60 Hz for 1 phase motors, 2 hp at 200...208 V AC 50/60 Hz for 3 phase motors, 5 hp at 460...480 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 575...600 V AC 50/60 Hz for 3 phase motors
- Control Circuit Type : DC
- Maximum Motor Phase Current : 12 A
- Maximum Operating Rate : 3600 cyc/h 60 °C
- Minimum Switching Current : 5 mA for signalling circuit
- Minimum Switching Voltage : 17 V for signalling circuit
- Rated Breaking Capacity : 250 A at 440 V for power circuit
- Important Information Attributes
- Persona Type Ids : OM, OM8, PB, SC
- Persona Type Names : Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
- Market Segmentation Id : RESIDENTIAL, COMMERCIAL, INDUSTRIAL
- Market Segmentation : Residential, Commercial, Industrial
- Associated Fuse Rating : 25 A gG at <= 690 V coordination type 1 for power circuit, 20 A gG at <= 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit
- Contactor Application : resistive load, motor control
- Disconnector Device Type : associated fuse, J fuse, 25 A at 600 V with 100 kA breaking capacity, associated circuit breaker, 35 A at 480 V with 35 kA breaking capacity, associated circuit breaker, 35 A at 600 V with 18 kA breaking capacity
- Electrical Durability : 1 Mcycles 12 A AC-3 <= 440 V, 0.6 Mcycles 25 A AC-1 <= 440 V
- Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit> 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
- Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz), vibrations contactor closed 4 Gn, 5...300 Hz), shocks contactor open 10 Gn for 11 ms), shocks contactor closed 15 Gn for 11 ms)
- Motor Power Kw : 3 kW 220...230 V AC 50/60 Hz, 5.5 kW 380...400 V AC 50/60 Hz, 5.5 kW 415 V AC 50/60 Hz, 5.5 kW 440 V AC 50/60 Hz, 7.5 kW 500 V AC 50/60 Hz, 7.5 kW 660...690 V AC 50/60 Hz
- Mounting Support : rail, plate
- Operating Time : 65.45...88.55 ms closing, 20...30 ms opening
- Power Dissipation Per Pole : 1.56 W AC-1, 0.2 W AC-3
- Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Tightening Torque : control circuit 1.7 N.m screw clamp terminals Philips No 2power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
- Utilisation Category : AC-3, AC-1, AC-4
- Certificate Agency : cULus, CB Scheme, CE, CCC
- [Ie] Rated Operational Current : 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
- [Ith] Conventional Free Air Thermal Current : 25 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
- [Ue] Rated Operational Voltage : 230...240 V 3-phase, 115 V single phase, 230...240 V single phase, 200...208 V 3-phase, 460...480 V 3-phase, 575...600 V 3-phase, 230/240 V, 200/208 V, 460/480 V
- [Ui] Rated Insulation Voltage : 690 V, 600 V
- Connections - Terminals : power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable endpower circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
- Non-overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
- Carbon Footprint Of The Distribution Phase [A4] : 0.14839419227412126, 0.1 kg CO2 eq.
- Carbon Footprint Of The End-of-life Phase [C1 To C4] : 1 kg CO2 eq., 1.3003129381185559
- Carbon Footprint Of The Installation Phase [A5] : 0.04109287085369836, 0 kg CO2 eq.
- Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 3 kg CO2 eq., 2.6849853456684607
- Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 16 kg CO2 eq., 15.627437837837837
- Local Data Status : Publishable
- Local Publishable Date : 2026-03-26
- Return Indicator : Y
- Future Imap : 23.66
- Future Msrp : 30.76
- Stocking Flag : Y
- Stock Policy : 1
- Device Type : LV equipment - LV contactor
- Serviceability : No
- Traceability : No
- Field Service Division : PPIBS
- Average Life Duration : 20 year(s)
- Weee Scope : In
- Weee Product Category : 5
- Scope Perimeter : At least in Europe
- Eoli Availability Display : Yes
- End Of Life Doc Ref : ENVEOLI1102030EN
- Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
- Reach Full Compliance Status Id : CONTAINS_SVHC
- Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
- Rohs Eur In Scope : Yes
- Rohs Eur Status : Compliant By Exemption
- Rohs Eur Conformity Date : 1929
- Rohs Eur Full Compliance Status : Compliant By Exemption
- China Rohs In Scope : No
- With Recycled Cardboard : Yes
- Without Single Use Plastic : Yes
- Product Contributes To Saved And Avoided Emissions : No
- Tier Id : 1
- Tier : 1
- Function Option Id : STANDARD
- Function Option : Standard
- Product Kit Identifier : N
- Average Impedance : 2.5 mOhm
- Coil Technology : without built-in suppressor module
- Device Short Name : DPE
- Energy Efficiency Optimized : False
- Fire Resistance : 850 °C
- Flame Retardance : V1 conforming to UL 94
- Heat Dissipation : 2-3 W 50/60 Hz
- Inrush Power In W : 2.4-2.4 W 20 °C)
- Mechanical Durability : 10 Mcycles
- Number Of Poles : 3P
- Overvoltage Category : III
- Pole Contact Composition : 3 NO
- Product Availability : Stock - Normally stocked in distribution facility
- Product Name : Easy TeSys DPE
- Product Or Component Type : contactor
- Protective Treatment : TH
- Range : Easy TeSys
- Returnability : Yes
- Signalling Circuit Frequency : 25...400 Hz
- Software Version : v5.9.4
- Sustainable Packaging : Yes
- Total Lifecycle Carbon Footprint : 20 kg CO2 eq.
- Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Inf Motor Phase Current : 12 A
- Control Circuit Voltage 18 : 24 V DC
- Pep Code : ENVPEP110230EN
- Database Version : 2022-01
- Pep Verification Date : 2025-08-05
- Pcr Version : PEP-PCR-ed4-2021 09 06
- Psr Version : PSR-0005-ed2-2016 03 29
- Type Of Verification For The Pep : Independent external review
- Data Source : extrapolated product
- Functional-unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type 3NO, a control circuit voltage 24V DC,a power circuit voltage 690V and a rated operational current 9A.
- Functional-unit Quantity : 1
- Functional-unit Unit : unit
- Reference Lifetime, In Y : 20
- Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; FR
- Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; FR
- Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; FR
- Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; FR
- Recyclability Potential, In % : 75
- Height Nominal : 77 mm
- Width Nominal : 45 mm
- [Uc] Control Circuit Voltage : 24 V DC
- [Uimp] Rated Impulse Withstand Voltage : 6 kV
- Hold-in Power Consumption In W : 2.4-2.4 W 20 °C
- Nbr. Of Units In Pkg. : 1
- Package Weight(Lbs) : 350.0 g
- Take-back : No
- Warranty (In Months) : 18
- Environment Attributes Main
- China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
- Ambient Air Temperature For Operation : -40-60 °C, -40-60 °C
- Ambient Air Temperature For Storage : -60-80 °C, -60-80 °C
- Take Back : No
- Recycled Metal Content At Cr Level : 0 %
- Toxic Heavy Metal Free : Yes
- Mercury Free : Yes
- Carbon Footprint : 19.802223184752673
- Circularity Profile : ENVEOLI1102030EN
- Environmental Disclosure : ENVPEP110230EN
- Eu Rohs Directive : Compliant By Exemption
- Ip Degree Of Protection : IP20 front face
- Operating Altitude : 0...6561.68 ft (0...2000 m)
- Packaging Made With Recycled Cardboard : Yes
- Packaging Without Single Use Plastic : Yes
- Reach Regulation : Reference contains Substances of Very High Concern above the threshold
- Pep Code : ENVPEP110230EN
- Pep Verification Date : 2025-08-05
- Pcr Version : PEP-PCR-ed4-2021 09 06
- Psr Version : PSR-0005-ed2-2016 03 29
- Type Of Verification For The Pep : Independent external review
- General Attributes
- Product Or Component Type : contactor
- ETIM
- ETIM 8 : EC000066
- ETIM 9 : EC000066
- Output Attributes
- Continuous Output Current : 25-25 A
- Specifications
- Country of Origin : Indonesia
- Depth : 86 mm