SQUARE D

feeder protection relay, PowerLogic P3F30 3CT 2Io ringlug 4VT 6DI 10DO 110-230V DI110V 3BIO 6ARC RS485 RJ45 ANSI

P3F30-CBGAD-DA1FA-BBAAB, RS48

SQDREL52128 REL52128 3606481465627
3319.30 / EA
http://schema.org/OutOfStock
  • Depth: 9.06 in
  • Height: 6.93 in
  • Number of Outputs: 10 DO, 1 Watchdog
  • Warranty Length: 10 yr, 2 yr
  • Width: 10.63 in
Perfectly suited for buildings and industry, utilities, and large industrial processes. The relay include protection for overcurrent, overload, broken conductor, earth-fault and breaker failure as per ANSI. It also feature an automatic recloser, a switch ON to fault, inrush protection and lockout among others. Simple, reliable, safe and easy-to-use, thanks to the User Interface display. The protection relay can to be supplied by a 48 VAC/VDC to 230 VAC/VDC network. The relays are certified with EN 60255-26 for electromagnetic compatiblity.
QTY
  • Product Description
  • Specifications
Perfectly suited for buildings and industry, utilities, and large industrial processes. The relay include protection for overcurrent, overload, broken conductor, earth-fault and breaker failure as per ANSI. It also feature an automatic recloser, a switch ON to fault, inrush protection and lockout among others. Simple, reliable, safe and easy-to-use, thanks to the User Interface display. The protection relay can to be supplied by a 48 VAC/VDC to 230 VAC/VDC network. The relays are certified with EN 60255-26 for electromagnetic compatiblity.
  • Communications & Management Attributes
    • Communication Port Protocol : IEC 61850 ed. 1, IEC 61850 ed. 2, IEC 60870-5-101, DNP3 TCP, Modbus TCP, EtherNet/IP, IEC 60870-5-103, DNP3, Modbus RTU, DeviceNet, SPAbus
  • Physical Attributes
    • Mounting Case Size : 30TE
  • Complementary Attributes
    • Integrated Connection Type : front USB port 1, rear RJ45 1, rear RS485 1
    • US Rated Supply Voltage : 48...230 V AC/DC
  • Important Information Attributes
    • Control Type : switchgear control and monitoring, programmable switchgear interlocking, local control on single-line diagram, local control with I/O keys, local/remote control, 2 function keys, mobile application with Easergy SmartApp, web-server, programmable logic
    • Display Type : LCD 128 x 128 pixels with single line diagram, LCD 128 x 128 pixels with ANSI symbols
    • Electromagnetic Compatibility : emission tests IEC/EN 60255-26 ed. 3, emission tests class A CISPR 11, emission tests class A CISPR 22, EMC immunity IEC/EN 60255-26 ed. 3, EMC immunity EN/IEC 61000-4-18, EMC immunity IEC 60255-22-1, EMC immunity level 4 EN/IEC 61000-4-2, EMC immunity IEC 60255-22-2, EMC immunity level 3 EN/IEC 61000-4-3, EMC immunity IEC 60255-22-3, EMC immunity level 4 EN/IEC 61000-4-4, EMC immunity IEC 60255-22-4, EMC immunity level 3 EN/IEC 61000-4-5, EMC immunity IEC 60255-22-5, EMC immunity level 3 EN/IEC 61000-4-6, EMC immunity IEC 60255-22-6, EMC immunity EN/IEC 61000-4-8, EMC immunity level 5 EN/IEC 61000-4-9, EMC immunity EN/IEC 61000-4-29, EMC immunity EN/IEC 61000-4-11, EMC immunity EN/IEC 61000-4-17, EMC immunity IEC 60255-27, EMC immunity class III IEC 60255-5, EMC immunity EN/IEC 60255-1
    • Environmental Characteristic : exposure to dry heat Bd EN/IEC 60068-2-2, exposure to cold Ad EN/IEC 60068-2-1, exposure to damp heat in service Db EN/IEC 60068-2-30, exposure to damp heat in service Cab EN/IEC 60068-2-78
    • Local Signalling : 2 LEDs, 16 LEDs programmable
    • Mechanical Robustness : vibrations class II) IEC 60255-21-1, vibrationsFc IEC 60068-2-6, shocks class II) IEC 60255-21-2, shocksEa IEC 60068-2-27, seismic tests method A class II) IEC 60255-21-3
    • Monitoring Function : trip circuit supervision 74, circuit breaker monitoring, relay self-monitoring
    • Protection Type : fault locator 21FL, synchro-check 25, undervoltage 27, directional active underpower 32, broken conductor 46BC, thermal overload protection 49, earth fault overcurrent 50N/51N, phase overcurrent 50/51, breaker failure 50BF, switch ON to fault (SOTF), capacitor bank unbalance 51C, voltage-restrained overcurrent 51V, capacitor overvoltage 59C, overvoltage 59, earth fault overvoltage 59N, directional phase overcurrent 67, directional earth fault 67N, transient earth fault 67NI, magnetising inrush detection 68F2, H5 detection 68H5, recloser 79, underfrequency 81/81N, rate of change of frequency 81R, lockout relay 86, programmable stages 99 8-8, programmable curve, cold load pick-up, CT supervision 60, VT supervision 60FL
    • Software Name : eSetup Easergy Pro virtual simulation test, Easergy SmartApp
    • Switchgear Diagnosis Type : CT/VT supervision, trip circuit supervision TCS
    • Type Of Measurement : current 3-phase, current zero sequence, current positive sequence, current negative sequence, current ratio of negative and positive, voltage phase to earth, voltage phase to phase, voltage zero sequence, voltage positive sequence, voltage negative sequence, voltage ratio of negative and positive, short circuit fault reactance, fault location current, earth fault reactance, frequency, active power, RMS active power, reactive power, RMS reactive power, apparent power, RMS apparent power, active energy, reactive energy, cos φ, tan φ, power angle, power factor, voltage phasor diagram view, current phasor diagram view, current 2nd, 15th harmonics with THD, voltage 2nd, 15th harmonics with THD, condition monitoring CB wear, voltage interruption
    • Carbon Footprint Of The Distribution Phase A4 : 4.81196451758779, 5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 11 kg CO2 eq., 11.244770232756933
    • Carbon Footprint Of The Installation Phase A5 : 0.17582600775273327, 0.2 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 167 kg CO2 eq., 167.06215675529174
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 1 056 kg CO2 eq., 1056.3500660970483
    • Connections Terminals : screw removable (digital input/output), ring lugs fixed (current transformer), pin removable (voltage transformer)
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Device Type : Relay, Control & Measurement - Protection relay
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1706005_V2
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : Yes
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : L - LOB initialized
    • Arc Flash Protection : yes
    • Device Short Name : P3F30-CBGAD-DA1FA-BBAAB
    • Number Of Key : 2 customizable
    • Operating Threshold : 110 V AC/DC
    • Package Weight Lbs : 5.3 kg
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : protection relay
    • Protective Treatment : conformal coating
    • Range Of Product : PowerLogic P3
    • Relay Application : feeder
    • Returnability : Yes
    • Single Line Diagram : 3 controlled + 5 displayed
    • Sustainable Packaging : No
    • Time Synchronisation Protocol : SNTP
    • Total Lifecycle Carbon Footprint : 1 240 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP1706005EN
    • Pep Verification Date : 2025-09-30
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.Protect distribution networks and high voltage equipment like feeder, transformer, motor and generator against faults, (short circuit, over load …) 24h per day, for 10 years of continuous operations.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Mercury Free : Yes
    • Carbon Footprint : 1239.6447836104376
    • Ambient Air Temperature For Operation : -40-65 °C
    • Circularity Profile : ENVEOLI1706005_V2
    • Environmental Disclosure : ENVPEP1706005EN
    • IP Degree Of Protection : IP54 front IEC 60529
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 0-95 %, without condensation
    • Pep Code : ENVPEP1706005EN
    • Pep Verification Date : 2025-09-30
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : protection relay
    • Range Of Product : PowerLogic P3
  • Output Attributes
    • Number Of Outputs : 10 DO, 1 watchdog
    • Analogue Output Number : 0
  • Contractual Warranty Attributes
    • Warranty Period : up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
    • Warranty : up to 10 years (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)
  • Input Attributes
    • Input Type : 3 1/5 A CT phase current, 1 5/1 A CT residual current, 1 1/0.2 A CT residual current, 4 100 V/110 V VT voltage
    • Analogue Input Number : 0
    • Digital Input Number : 6
  • Specifications
    • Height : 6.93 in
    • Width : 10.63 in
    • Depth : 9.06 in