Main circuit breaker unit, EZ Meter-Pak, 1200A, 3 phase, 4 wire, 1200A busbar, 1200A CB, EUSERC

EZM METER 3PH 1200A MAIN CB EU

SQDEZM31200JCBE EZM31200JCBE 785901939511
8898.63 / EACH
http://schema.org/OutOfStock
  • Certifications: EUSERC, UL Listed
  • Depth: 13.69 in
  • Enclosure Material: Steel
  • Height: 66.20 in
  • Material: Aluminium: Busbar
  • Mounting Type: Surface
  • Number of Phases: 3
  • Warranty Length: 18 mth
  • Width: 32.39 in
Square D EZ Meter-Pak main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. EZM main circuit breaker provides circuit protection and a main disconnect point suitable for service equipment. This main circuit breaker unit supplies three phases in, three phases out with a four wire configuration. It is rated for 208Y/120VAC or 240/120VAC delta and 1200A. It comes with a factory installed 3 pole 1200A circuit breaker. It is suitable for underground service feed with conduit entrances at the bottom of the compartment. The compartment has four horizontal 1200A rated busbars. The busbars come with Visi-Tite joint nuts for connections, eliminating the need for torque readings. It is compliant with UL and EUSERC standards and the steel enclosure has a rating of NEMA 3R.
QTY
  • Product Description
  • Specifications
Square D EZ Meter-Pak main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. EZM main circuit breaker provides circuit protection and a main disconnect point suitable for service equipment. This main circuit breaker unit supplies three phases in, three phases out with a four wire configuration. It is rated for 208Y/120VAC or 240/120VAC delta and 1200A. It comes with a factory installed 3 pole 1200A circuit breaker. It is suitable for underground service feed with conduit entrances at the bottom of the compartment. The compartment has four horizontal 1200A rated busbars. The busbars come with Visi-Tite joint nuts for connections, eliminating the need for torque readings. It is compliant with UL and EUSERC standards and the steel enclosure has a rating of NEMA 3R.
  • Environment
    • Product Certifications : UL Listed || EUSERC
    • Nema Degree Of Protection : NEMA 3R
  • Contractual warranty
    • Warranty : 18 months
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Eu Rohs Directive : Compliant with Exemptions
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary
    • Service Feed Location : UG
    • Height : 66.20 in
    • Phase : 3 phase in || 3 phase out
    • Device Mounting : surface
    • [Ue] Rated Operational Voltage : 208Y/120 V AC
    • Material : aluminium: busbar
    • Bus Rated Current : 1200 A
    • Enclosure Material : steel
    • Wiring Configuration : 4-wire
    • Width : 32.39 in
    • Depth : 13.69 in
    • Main Rated Current : 1200 A
    • Electrical Connection : lugs 1 AWG 6...300 kcmil aluminium/copper) ground || studs 3 line || studs 3 neutral
  • Specifications
    • Range Of Product : EZ meter-pak
    • Main Type : Main Circuit Breaker
    • Provided Equipment : closing plate || circuit-breaker3P 1200 A
    • Product Or Component Type : meter center main unit