Main fusible (Class T) switch unit, EZ Meter-Pak, 400A, 240VAC max, 3ph/4W, 400A bus, UG, Type 3R, EUSERC

Main fusible (Class T) switch unit, EZ Meter-Pak, 400A, 240VAC max, 3ph/4W, 400A bus, UG, Type 3R, EUSERC

SQDEZM3400FSU EZM3400FSU 785901305170
2788.15 / EACH
http://schema.org/OutOfStock
  • Depth: 11.5 in
  • Enclosure Material: Painted Steel
  • Warranty Length: 18 mth
Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install. Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices. External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main fusible switch provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from UG feeds. The unit is rated for 400A with the busbar rated for 400A. With a 300V Class T fuse, the short circuit current rating is 100kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL and EUSERC standards.
QTY
  • Product Description
  • Features
  • Specifications
Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install. Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices. External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main fusible switch provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from UG feeds. The unit is rated for 400A with the busbar rated for 400A. With a 300V Class T fuse, the short circuit current rating is 100kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL and EUSERC standards.
  • Features
    • Main circuit breaker, fusible switch, or lug terminal boxes available
    • Meter-Pak units from 225A to 2000A
    • Visi-Tite nuts eliminate special tools and torque readings
    • Rotating mounting brackets pivot for drilling holes without moving the device
    • External mounting channels allow immediate installation
    • Compact footprint for installation flexibility
    • NEMA Type 3R for outdoor and indoor installation
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL Listed, EUSERC
  • Complementary Attributes
    • Bus Rated Current : 400 A
    • Main Rated Current : 400 A
  • Important Information Attributes
    • Persona Type Ids : EU, LC
    • Persona Type Names : End User, Contractor
    • Electrical Connection : lugs 1 AWG 6...300 kcmil aluminium/copper) ground, studs 1 line, studs 1 neutral
    • Phase : 3 phase in, 3 phase out
    • Provided Equipment : main switch 1 ) 3P 400 A 100 kA, closing plate
    • Ue Rated Operational Voltage2 : 208Y/120 V AC, 240/120 V delta AC
    • Carbon Footprint Of The Distribution Phase A4 : 18.272634538863763, 18 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 146 kg CO2 eq., 145.88685353255593
    • Carbon Footprint Of The Installation Phase A5 : 7.208571153043661, 7 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 966 kg CO2 eq., 966.4697652917699
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 22 534 kg CO2 eq., 22534.233203799893
    • Ue Rated Operational Voltage5 : 208Y/120 V AC, 240/120 V delta AC
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : No
    • Legacy WEEE Scope : In
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status Id : COMPLIANT_WITH_EXEMPTIONS
    • China ROHS In Scope : No
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • H And D Domain : Safety
    • H And D Subrange : RESI
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : ENCLOSURES
    • H And D Enrichment Class 3 : Meter enclosures
    • H And D Enrichment Class 4 : Three-phase multi-tenant meter enclosure
    • Enclosure Material : painted steel
    • Energy Efficiency Optimized : False
    • Main Type : Main Fusible Switch
    • Package Weight Lbs : 99.79 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : meter center main unit
    • Range Of Product : EZ meter-pak
    • Returnability : No
    • Service Feed Location : UG
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 23 672 kg CO2 eq.
    • Wiring Configuration : 4-wire
    • Medium Desc : Main fusible (Class T) switch unit, EZ Meter-Pak, 400A, 240VAC max, 3ph/4W, 400A bus, UG, Type 3R, EUSERC
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP2011003EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-10-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : When a product covered by this PSR includes additional functions, the functional unit defined in the PSR shall be used and shall be completed in order to take into account these additional functionsTo ensure the protection of individuals from direct contact with live active parts and to facilitate the grouping of control, command, and protection devices within a single enclosure or cabinet of dimensions H × L × D, or an assembly of X enclosures or cabinets of the same dimensions, with a rated current In, designed for use in Household/Commercial applications. The unit shall protect the electrical installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, number of poles Np, rated breaking capacity Icn. The product is expected to perform its intended function reliably over a reference service life of 20 years.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; Mexico, MX
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Global Commercial Status : Commercialised
  • Environment Attributes Main
    • China ROHS Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • EU ROHS Directive : Compliant By Exemption , Compliant with Exemptions
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 23672.071028316128
    • Environmental Disclosure : ENVPEP2011003EN
    • Nema Degree Of Protection : NEMA 3R
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2011003EN
    • Pep Verification Date : 2025-10-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Phase : 3 phase in, 3 phase out
    • Provided Equipment : main switch 1 ) 3P 400 A 100 kA, closing plate
    • Product Or Component Type : meter center main unit
    • Range Of Product : EZ meter-pak
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 11.50 in