EM4800 multi-circuit energy meter - 24 x 5 A inputs, 120 V - 60 Hz

EM4800 multi-circuit energy meter - 24 x 5 A inputs, 120 V - 60 Hz

SQDMETSEEM480516 METSEEM480516 3606486441183
19702.75 / EA
http://schema.org/OutOfStock
  • Depth: 5.5 cm
  • Display Type: Backlit LCD
  • Number of Outputs: 0
  • Warranty Length: 18 mth
This multi-circuit power meter is part of the PowerLogic EM4800 Series. This compact multi-circuit energy meter enables reliable metering of individual tenants with a low installation cost-per-point. It combine revenue-accurate electricity sub-metering with advanced communications technology. It is ideal for multi-tenant or departmental metering applications within office, condominiums, malls and other multi-user environments. This version monitor up to 24 tenants with a single device, combined with 5 amps split or solid core current transformers. Designed for 120 volts networks, working at 60 Hz. Measurement accuracy is plus or minus 0.5 %, compliant with ANSI C12.1 and C12.20 Class 0.5 ; IEC 62053-22 Class 0.5S. The printed board is installed in a Type 1 black enclosure, with an integrated backlit LCD display, 2 lines, on the door. Mechanical dimensions are 335 mm in width, 440 mm in height and 55 mm in depth ; for 5.4 kg.
QTY
  • Product Description
  • Features
  • Specifications
This multi-circuit power meter is part of the PowerLogic EM4800 Series. This compact multi-circuit energy meter enables reliable metering of individual tenants with a low installation cost-per-point. It combine revenue-accurate electricity sub-metering with advanced communications technology. It is ideal for multi-tenant or departmental metering applications within office, condominiums, malls and other multi-user environments. This version monitor up to 24 tenants with a single device, combined with 5 amps split or solid core current transformers. Designed for 120 volts networks, working at 60 Hz. Measurement accuracy is plus or minus 0.5 %, compliant with ANSI C12.1 and C12.20 Class 0.5 ; IEC 62053-22 Class 0.5S. The printed board is installed in a Type 1 black enclosure, with an integrated backlit LCD display, 2 lines, on the door. Mechanical dimensions are 335 mm in width, 440 mm in height and 55 mm in depth ; for 5.4 kg.
  • Prop 65
    • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Of Data : apparent energy, positive reactive energy, voltage, negative active energy, positive active energy, negative reactive energy
    • Communication Port Protocol : BACnet IP, FTP, HTTP, Modbus TCP/IP, SNTP
    • Communication Port Support : RJ45 ETHERNET, RJ11 modem, SUB-D 9 RS232
  • Important Information Attributes
    • Energy Management : billing analysis, sub billing and cost allocation
    • Market Segment : buildings medium building cost management: cost allocation: panelboard, buildings large building cost management: cost allocation: panelboard, buildings multi-site cost management: cost allocation: panelboardbuildings small building cost management: billing: panelboard, buildings medium building cost management: billing: panelboard, buildings large building cost management: billing: panelboard, buildings multi-site cost management: billing: panelboard, buildings small building cost management: cost allocation: panelboard
    • Measurement Voltage : 80-480 V, 480-999000 V with external VT
    • Type Of Measurement : current per phase, rms, voltage per phase, rms, negative reactive energy, apparent energy, pulse count, positive active energy, positive reactive energy, negative active energy
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-10
    • Return Indicator : Y
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : DPIBS
    • Average Life Duration : 15 year(s)
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI111006EN
    • Rohs Eur In Scope : Yes
    • China Rohs In Scope : No
    • With Recycled Cardboard : No
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Compatibility Code : EM4800
    • Device Application : sub billing
    • Device Short Name : EM4800
    • Display Type : Backlit LCD
    • Energy Efficiency Optimized : False
    • Measurement Accuracy : +/- 0.5 % of the measuring range+/- 0.5 % of the measuring range
    • Messages Display Capacity : 2 lines of 16 characters
    • Mounting Mode : wall mount
    • Network Frequency : 60 Hz
    • Power Monitoring : basic instrumentation
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : PowerLogic EM4800
    • Product Or Component Type : multi-circuit energy meter
    • Range : PowerLogic
    • Range Of Product : PowerLogic
    • Returnability : Yes
    • Sampling Rate : 256 samples/cycle
    • Sustainable Packaging : No
    • Pep Code : ENVPEP111007EN
    • Height Nominal : 44 cm
    • Width Nominal : 33.5 cm
    • Certificate Agency : UL
    • [Us] Rated Supply Voltage : 120 V AC 60 Hz
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 1 kg
    • Take-back : No
    • Warranty (In Months) : 18
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Storage : -40-70 °C, -40-70 °C
    • Operating Altitude : <= 9842.52 ft (3000 m), <= 9842.52 ft (3000 m)
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Ambient Air Temperature For Operation : -40-70 °C-40-70 °C
    • Circularity Profile : ENVEOLI111006EN
    • Environmental Disclosure : ENVPEP111007EN
    • Eu Rohs Directive : Will be compliant – Date to be confirmed
    • Packaging Made With Recycled Cardboard : No
    • Packaging Without Single Use Plastic : No
    • Relative Humidity : 90-90 % 40-40 °C
    • Pep Code : ENVPEP111007EN
  • General Attributes
    • Product Or Component Type : multi-circuit energy meter
    • Range Of Product : PowerLogic
  • ETIM
    • ETIM 8 : EC002301
    • ETIM 9 : EC002301
  • Output Attributes
    • Number Of Outputs : 0
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Input Attributes
    • Analogue Input Type : split core CT 5 A12 x single phase, split core CT 5 A8 x three phasesolid core CT 5 A24 x single pole, solid core CT 5 A12 x single phase, solid core CT 5 A8 x three phase, split core CT 5 A24 x single pole
    • Number Of Inputs : 2 pulse
  • Specifications
    • Country of Origin : Canada, Mexico, United States
    • Depth : 5.5 cm