Mini circuit breaker, E-Frame, 70A, 3 pole, 480Y/277VAC, 100kA max, bolt on, shunt trip [TAA]

MINIATURE CIRCUIT BREAKER 480Y

SQDEJB34070SA EJB34070SA 785901523048
4984.65 / EACH
http://schema.org/OutOfStock
  • Module Type: E-Frame
  • Warranty Length: 18 mth
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 70A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. HACR rated.
QTY
  • Product Description
  • Features
  • Specifications
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 70A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. HACR rated.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • UE Rated Operational Voltage : 480Y/277 V AC, 480Y/277 V AC
  • Environment Attributes Additional
    • Energy Model Manufacturing A1 A3 : Electricity Mix; Low voltage; 2020; Mexico, MX
    • Energy Model Installation A5 : No energy used
    • Energy Model Use B6 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 : Global, European and French datasets are used.
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 0.11030802891007727
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.0964380228256853
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.0010919896229850197
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.0008034648731409089
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 0.006092917380671635
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.005881634207594396
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.041430395020388686
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C BLB SysBound D : 0
    • Biogenic Carbon Content Of The Product Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Product Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Product Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 0.2910359218642489
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : -0.715543305896053
    • Climate Change Biogenics Kg Co2 Eq Distribution A4 : 0.0000032148289991582
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.6130436001005938
    • Climate Change Biogenics Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Biogenics Kg Co2 Eq Repair B3 : 0
    • Climate Change Biogenics Kg Co2 Eq Replacement B4 : 0
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 0.006765223401187115
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.3867671894295219
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.09198786419529527
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 19.676396125072603
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 14.824889743431626
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 0.6327645545610348
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.1330832154155942
    • Climate Change Fossil Fuels Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Repair B3 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Replacement B4 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 1.395057010627783
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 2.6906016010365668
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -1.4091841608880415
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 19.967436486996593
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 14.109349438534778
    • Climate Change Total Kg Co2 Eq Distribution A4 : 0.6327689575976025
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.7461268168393775
    • Climate Change Total Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Total Kg Co2 Eq Repair B3 : 0
    • Climate Change Total Kg Co2 Eq Replacement B4 : 0
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 1.40182223402897
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 3.077369039995865
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -1.501172025083337
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.03108131928346838
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.031080330821691066
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.00000051852112712265
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.00000001911114119747
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.00000032982091699664
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.0000001210085919959
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb BLB SysBound D : -0.0006727192366840902
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 335.8731605259878
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 276.40791865172696
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 11.59976489239546
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 2.4658146341591967
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 30.4138744356491
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 14.98578791205711
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -30.618529914187484
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 11172.504766995571
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 11101.304214659142
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 22.897964782787664
    • Ecotoxicity Fresh Water Ctue Installation A5 : 3.2985462476293215
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 1.670117629527107
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 43.333923676486556
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -10.836700870031018
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.00000132683452395144
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.00000122544601897033
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.00000000971196905571
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0.00000000560162001954
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.0000000451329743787
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.00000004094194152717
    • Emission Of Fine Particles Incidence Of Diseases BLB SysBound D : -0.0000007695087472664
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.0002449366278880029
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.000219392782752186
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.00000240839941124175
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.00000015735170657113
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.00000235453766871397
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.00002062355634929002
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.00000182163171776832
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 82.0898834427682
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 81.93420329591595
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0.0032784424027196674
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.1448626220406143
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.007539082408914455
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -52.50085470812605
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.00000145586227668883
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000145467255121925
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0.00000000015421423989
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0.00000000002395871661
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000000016274037341
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000084881213967
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000366870640411767
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.00000142394561252268
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000140870064929803
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0.0000000030582083559
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0.00000000096946489872
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000000387897224473
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.0000000073383177253
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000053468427909933
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 0.13548214174536627
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 0.08973987375154091
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0.003361179654649302
    • Impacts Related To Land Use Soil Quality Installation A5 : 0.0028599969745487838
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 0.02954427476091118
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.0099768166037161
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 8.590916042136381
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 7.051291326812868
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.02728359927423399
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.048877329101127076
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 1.285122854323384
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 0.1783409326247669
    • Ionizing Radiation Human Health Kbq Of U235 Equiv BLB SysBound D : -0.8068384829884
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.01310350991985557
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.010315155198146091
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.00020417766481868323
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.00020239756312003288
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.0007783999915329658
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.0016033795022377968
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0010557515796532498
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 0.5835302117610872
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.08964312679507015
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.4938870849660171
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.12429237075334872
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.11450987026427238
    • Net Use Of Fresh Water M3 Distribution A4 : 0.000616230857349041
    • Net Use Of Fresh Water M3 Installation A5 : 0.00017534812703931454
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.001930015213521714
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.007060906291166277
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.04961292534638887
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 5.9496682425330985
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 3.9203150933079414
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.07290428658779917
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.017573626645362248
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.2264199705763508
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 1.7124552654156453
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.8642074508644071
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.00000093694524599291
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.00000089181607301292
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.00000000915616613615
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.00000000478151362866
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.00000000503126979835
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.00000002616022341683
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.00000028562417401963
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 0.04516249935777407
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.03665604879424299
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.0007225557175295458
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.0005676629835403639
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 0.002566780778983087
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.004649451083478094
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.006179196116125414
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.0014857706896393961
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0013119707722338341
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.00005771931982736436
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.00000733084623740809
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.00005259789789466586
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.00005615185344612361
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.00040880303689174336
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 0.1321810012833268
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.09979272467613141
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.0022404275940563654
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.0026642120557659496
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 0.009328698525549019
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.018154938431824048
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.01240488372369132
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj TLC : 36.28068059138463
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 36.28068059138463
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 356.3180826454578
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 290.2042106146305
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 11.643752661152394
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 2.677855154969999
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 36.05389361413643
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 15.73837060056851
    • Total Use Of PrE During The Life Cycle Mj BLB SysBound D : -31.238280941504822
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj TLC : 20.44491513011781
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 13.79628497355135
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.04398776875693264
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.21204052081080246
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 5.640019178487326
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.752582688511398
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : -0.619751027317339
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 36.28068059138463
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 36.28068059138463
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj TLC : 299.5924869239554
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Mfg A1 A3 : 240.12724504969452
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Dist A4 : 11.59976489239546
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Inst A5 : 2.4658146341591967
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 30.4138744356491
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj EoL C1 C4 : 14.98578791205711
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj BLB SysBound D : -30.618529914187484
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 3.4358592666890755
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 3.4358592666890755
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of RE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of RE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0.4767731092436974
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj TLC : 17.009055863428735
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Mfg A1 A3 : 10.360425706862275
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Dist A4 : 0.04398776875693264
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Inst A5 : 0.21204052081080246
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj OpEnergy B6 : 5.640019178487326
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.752582688511398
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj BLB SysBound D : -1.0965241365610365
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.2391980125210084
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.2391980125210084
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
    • Water Use M3 Eq Total Life Cycle : 5.303695833042368
    • Water Use M3 Eq Manufacturing A1 A3 : 4.918171795667249
    • Water Use M3 Eq Distribution A4 : 0.02646598908162426
    • Water Use M3 Eq Installation A5 : 0.007663813183051067
    • Water Use M3 Eq Maintenance B2 : 0
    • Water Use M3 Eq Repair B3 : 0
    • Water Use M3 Eq Replacement B4 : 0
    • Water Use M3 Eq Operational Energy Use B6 : 0.08282997970823561
    • Water Use M3 Eq End Of Life C1 C4 : 0.26856425540220863
    • Water Use M3 Eq Benefits Loads Beyond System Boundaries D : -2.130835178230612
    • Air Pollution M3 Total Life Cycle : 0
    • Air Pollution M3 Manufacturing A1 A3 : 0
    • Air Pollution M3 Distribution A4 : 0
    • Air Pollution M3 Installation A5 : 0
    • Air Pollution M3 Maintenance B2 : 0
    • Air Pollution M3 Repair B3 : 0
    • Air Pollution M3 Replacement B4 : 0
    • Air Pollution M3 Operational Energy Use B6 : 0
    • Air Pollution M3 End Of Life C1 C4 : 0
    • Air Pollution M3 Benefits Loads Beyond System Boundaries D : 0
    • Water Pollution M3 Total Life Cycle : 0
    • Water Pollution M3 Manufacturing A1 A3 : 0
    • Water Pollution M3 Distribution A4 : 0
    • Water Pollution M3 Installation A5 : 0
    • Water Pollution M3 Maintenance B2 : 0
    • Water Pollution M3 Repair B3 : 0
    • Water Pollution M3 Replacement B4 : 0
    • Water Pollution M3 Operational Energy Use B6 : 0
    • Water Pollution M3 End Of Life C1 C4 : 0
    • Water Pollution M3 Benefits Loads Beyond System Boundaries D : 0
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer
    • AWG Gauge : AWG 12...AWG 2/0 aluminium, AWG 12...AWG 2/0 aluminium, AWG 14...AWG 2/0 copper, AWG 14...AWG 2/0 copper
    • Electrical Connection : lugs aluminium, lugs aluminium
    • Product Destination : NF panelboard, NF panelboard
    • Tightening Torque : 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-19
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : Out
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • H And D Domain : Safety
    • H And D Subrange : COM
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : MCB
    • H And D Enrichment Class 3 : Circuit Breakers
    • H And D Enrichment Class 4 : MCB UL 3P
    • Device Short Name : EJB
    • Energy Efficiency Optimized : False
    • Holding Current : 630 A
    • Module Type : E-Frame
    • Package Weight Lbs : 1.97 kg
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : miniature circuit-breaker
    • Range Of Product : 125 A Frame EDB-EGB-EJB
    • Returnability : No
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 20 kg CO2 eq.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2510013EN
    • Pep Verification Date : 2025-11-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icn, and the tripping curve Cd if applicable, and, if applicable, the specific specifications, in the Household/Commercial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Huella De Carbono De La Fase De Distribución A4 : 0.6 kg CO2 eq.
    • Huella De Carbono De La Fase De Fabricación A1 A A3 : 14 kg CO2 eq.
    • Huella De Carbono De La Fase De Fin De Vida C1 A C4 : 3 kg CO2 eq.
    • Huella De Carbono De La Fase De Instalación A5 : 0.7 kg CO2 eq.
    • Huella De Carbono De La Fase De Uso B2 B3 B4 B6 : 1 kg CO2 eq.
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 19.967436486996593
    • Environmental Disclosure : ENVPEP2510013EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2510013EN
    • Pep Verification Date : 2025-11-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : miniature circuit-breaker
    • Range Of Product : 125 A Frame EDB-EGB-EJB
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Compliance : TAA