SQUARE D

Mini circuit breaker, E-Frame, 70A, 3 pole, 480Y/277VAC, 25kA max, bolt on, shunt trip [TAA]

MINIATURE CIRCUIT BREAKER 480Y

SQDEDB34070SA EDB34070SA 785901112846
1777.32 / EACH
http://schema.org/OutOfStock
  • IsSustainable: No
  • Module Type: E-Frame
  • Warranty Length: 18 mth
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 70A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. HACR rated.
QTY
  • Product Description
  • Features
  • Specifications
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 70A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. HACR rated.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • UE Rated Operational Voltage : 480Y/277 V AC, 480Y/277 V AC
  • Environment Attributes Additional
    • Energy Model Manufacturing A1 A3 : Electricity Mix; Low voltage; 2020; Mexico, MX
    • Energy Model Installation A5 : No energy used
    • Energy Model Use B6 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 : Global, European and French datasets are used.
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 0.10634044852190191
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.09276652449475818
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.0010504164139881283
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.0007728761089350368
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 0.006092917380671635
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.005657714123548924
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.03985309571758201
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C BLB SysBound D : 0
    • Biogenic Carbon Content Of The Product Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Product Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Product Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 0.2802134333440816
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : -0.6883018094786906
    • Climate Change Biogenics Kg Co2 Eq Distribution A4 : 0.00000309243703218517
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.5897043767465102
    • Climate Change Biogenics Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Biogenics Kg Co2 Eq Repair B3 : 0
    • Climate Change Biogenics Kg Co2 Eq Replacement B4 : 0
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 0.006765223401187115
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.3720425502380426
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.08848578814725103
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 18.980406057263792
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 14.260490387717224
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 0.608674533448305
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.128016595539366
    • Climate Change Fossil Fuels Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Repair B3 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Replacement B4 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 1.395057010627783
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 2.5881675299311135
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -1.355535017707025
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 19.260623761629805
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 13.5721914649865
    • Climate Change Total Kg Co2 Eq Distribution A4 : 0.608678768856577
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.7177209735586906
    • Climate Change Total Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Total Kg Co2 Eq Repair B3 : 0
    • Climate Change Total Kg Co2 Eq Replacement B4 : 0
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 1.40182223402897
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 2.960210320199068
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -1.4440208058542758
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.029898032882609827
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.02989706949599217
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.00000049878047507483
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.0000000183835596798
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.00000032982091699664
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.00000011640166590468
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb BLB SysBound D : -0.0006471080982316502
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 324.24399988803077
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 265.8847745406206
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 11.158149477710353
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 2.3719384425033896
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 30.4138744356491
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 14.415262991547321
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -29.452849841312325
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 10747.21918389788
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 10678.66572932948
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 22.026214854508947
    • Ecotoxicity Fresh Water Ctue Installation A5 : 3.172967075765261
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 1.670117629527107
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 41.684155008600015
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -10.424136116095827
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.00000127803877967836
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.00000117879198271511
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.0000000093422240409
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0.00000000538836037412
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.0000000451329743787
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.00000003938323816954
    • Emission Of Fine Particles Incidence Of Diseases BLB SysBound D : -0.00000074021272896946
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.00023570126912330914
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.0002110402656423312
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.00000231670907832646
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.00000015136115936664
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.00000235453766871397
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.00001983839557457086
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.00000175228025643197
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 78.96463407311965
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 78.81488083541153
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0.003153628605661812
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.1393475475974437
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.007252061505021773
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -50.502091204009574
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.00000140044224358037
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000139929161652816
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0.00000000014834313939
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0.00000000002304658273
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000000016274037341
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000081649695669
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000352903484050913
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.00000136988216175068
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000135506991391866
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0.00000000294177910377
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0.00000000093255633659
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000000387897224473
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000705894014692
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000051432827862601
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 0.13144897422057739
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 0.08632338109602539
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0.003233215962213415
    • Impacts Related To Land Use Soil Quality Installation A5 : 0.0027511138409999723
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 0.02954427476091118
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.009596988560427415
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 8.312776707574972
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 6.782841149396135
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.026244883565824065
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.04701651707951056
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 1.285122854323384
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 0.1715513032101184
    • Ionizing Radiation Human Health Kbq Of U235 Equiv BLB SysBound D : -0.7761212818594
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.012634279846442272
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.00992244624390195
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.00019640440346771812
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.00019469207213830574
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.0007783999915329658
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.0015423371354013323
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.001015557991595385
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 0.561314594562061
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.08623031739931875
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.4750842771627423
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.11963390544091876
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.11015035743695237
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0005927702917139252
    • Net Use Of Fresh Water M3 Installation A5 : 0.00016867243692360458
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.001930015213521714
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.006792090061807155
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.04772410839157711
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 5.731778079895151
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 3.771064518689619
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.0701287426821723
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.016904579945665715
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.2264199705763508
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 1.647260268001344
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.8313061519736302
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.00000090146628750835
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.00000085786368444644
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.00000000880758113097
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.00000000459947630777
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.00000000503126979835
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.00000002516427582482
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.00000027475015724223
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 0.04354083494487594
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.035260513941670284
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.0006950472511261368
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.0005460514486340049
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 0.002566780778983087
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.004472441524462431
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.005943947533024192
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.0014312082737100282
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.0012620226463873683
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.00005552188379332765
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.0000070517531065423
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.00005259789789466586
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.00005401409252812398
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.00039323946949738767
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 0.12750388315803068
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.09599350926967971
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.0021551321272775697
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.0025627826627799364
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 0.009328698525549019
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.01746376057274445
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.011932616576850281
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj TLC : 34.899436406433445
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 34.899436406433445
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 344.12528357066134
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 279.1558269617892
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 11.200462585220196
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 2.5759063546538825
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 36.05389361413643
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 15.139194054861587
    • Total Use Of PrE During The Life Cycle Mj BLB SysBound D : -30.04900628637139
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj TLC : 19.881276959370457
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 13.271045697908532
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.04231310750984129
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.20396791215049273
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 5.640019178487326
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.7239310633142635
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : -0.5961564450590646
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 34.899436406433445
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 34.899436406433445
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj TLC : 289.34457020485746
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Mfg A1 A3 : 230.98534485744727
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Dist A4 : 11.158149477710353
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Inst A5 : 2.3719384425033896
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 30.4138744356491
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj EoL C1 C4 : 14.415262991547321
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj BLB SysBound D : -29.452849841312325
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 3.305052441815126
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 3.305052441815126
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of RE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of RE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0.45862184873949574
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj TLC : 16.576224517555328
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Mfg A1 A3 : 9.965993256093405
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Dist A4 : 0.04231310750984129
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Inst A5 : 0.20396791215049273
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj OpEnergy B6 : 5.640019178487326
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.7239310633142635
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj BLB SysBound D : -1.0547782937985604
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.23009148920168065
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.23009148920168065
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
    • Water Use M3 Eq Total Life Cycle : 5.104931904615942
    • Water Use M3 Eq Manufacturing A1 A3 : 4.730931752684993
    • Water Use M3 Eq Distribution A4 : 0.025458400664811157
    • Water Use M3 Eq Installation A5 : 0.007372043645625264
    • Water Use M3 Eq Maintenance B2 : 0
    • Water Use M3 Eq Repair B3 : 0
    • Water Use M3 Eq Replacement B4 : 0
    • Water Use M3 Eq Operational Energy Use B6 : 0.08282997970823561
    • Water Use M3 Eq End Of Life C1 C4 : 0.25833972791227683
    • Water Use M3 Eq Benefits Loads Beyond System Boundaries D : -2.0497120115467053
    • Air Pollution M3 Total Life Cycle : 0
    • Air Pollution M3 Manufacturing A1 A3 : 0
    • Air Pollution M3 Distribution A4 : 0
    • Air Pollution M3 Installation A5 : 0
    • Air Pollution M3 Maintenance B2 : 0
    • Air Pollution M3 Repair B3 : 0
    • Air Pollution M3 Replacement B4 : 0
    • Air Pollution M3 Operational Energy Use B6 : 0
    • Air Pollution M3 End Of Life C1 C4 : 0
    • Air Pollution M3 Benefits Loads Beyond System Boundaries D : 0
    • Water Pollution M3 Total Life Cycle : 0
    • Water Pollution M3 Manufacturing A1 A3 : 0
    • Water Pollution M3 Distribution A4 : 0
    • Water Pollution M3 Installation A5 : 0
    • Water Pollution M3 Maintenance B2 : 0
    • Water Pollution M3 Repair B3 : 0
    • Water Pollution M3 Replacement B4 : 0
    • Water Pollution M3 Operational Energy Use B6 : 0
    • Water Pollution M3 End Of Life C1 C4 : 0
    • Water Pollution M3 Benefits Loads Beyond System Boundaries D : 0
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer
    • AWG Gauge : AWG 12...AWG 2/0 aluminium, AWG 12...AWG 2/0 aluminium, AWG 14...AWG 2/0 copper, AWG 14...AWG 2/0 copper
    • Electrical Connection : lugs aluminium, lugs aluminium
    • Product Destination : NF panelboard, NF panelboard
    • Tightening Torque : 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-19
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : Out
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : N
    • WD Status : 5 - INITIALIZED WITH DataSCAN OK (Migration)
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • H And D Domain : Safety
    • H And D Subrange : COM
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : MCB
    • H And D Enrichment Class 3 : Circuit Breakers
    • H And D Enrichment Class 4 : MCB UL 3P
    • Device Short Name : EDB
    • Energy Efficiency Optimized : False
    • Holding Current : 630 A
    • Module Type : E-Frame
    • Package Weight Lbs : 1.895 kg
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : miniature circuit-breaker
    • Range Of Product : 125 A Frame EDB-EGB-EJB
    • Returnability : No
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 19 kg CO2 eq.
    • Relationship Type : Compatible relationship
    • Pep Code : ENVPEP2510013EN
    • Pep Verification Date : 2025-11-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icn, and the tripping curve Cd if applicable, and, if applicable, the specific specifications, in the Household/Commercial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Huella De Carbono De La Fase De Distribución A4 : 0.6 kg CO2 eq.
    • Huella De Carbono De La Fase De Fabricación A1 A A3 : 14 kg CO2 eq.
    • Huella De Carbono De La Fase De Fin De Vida C1 A C4 : 3 kg CO2 eq.
    • Huella De Carbono De La Fase De Instalación A5 : 0.7 kg CO2 eq.
    • Huella De Carbono De La Fase De Uso B2 B3 B4 B6 : 1 kg CO2 eq.
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 19.260623761629805
    • Environmental Disclosure : ENVPEP2510013EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2510013EN
    • Pep Verification Date : 2025-11-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : miniature circuit-breaker
    • Range Of Product : 125 A Frame EDB-EGB-EJB
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Compliance : TAA