SQUARE D

Mini circuit breaker, E-Frame, 60A, 3 pole, 480Y/277VAC, 65kA max, bolt on, shunt trip [TAA]

BREAKER 3 POLE E FRAME NF PANE

SQDEGB34060SA EGB34060SA 785901769606
1874.12 / EACH
http://schema.org/OutOfStock
  • Module Type: E-Frame
  • Warranty Length: 18 mth
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 60A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. HACR rated.
QTY
  • Product Description
  • Features
  • Specifications
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 60A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. HACR rated.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • UE Rated Operational Voltage : 480Y/277 V AC, 480Y/277 V AC
  • Environment Attributes Additional
    • Energy Model Manufacturing A1 A3 : Electricity Mix; Low voltage; 2020; Mexico, MX
    • Energy Model Installation A5 : No energy used
    • Energy Model Use B6 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 : Global, European and French datasets are used.
    • Acidification Ap Mole Of H Equiv Total Life Cycle : 0.10496502065400114
    • Acidification Ap Mole Of H Equiv Manufacturing A1 A3 : 0.09149373840670347
    • Acidification Ap Mole Of H Equiv Distribution A4 : 0.001036004368202539
    • Acidification Ap Mole Of H Equiv Installation A5 : 0.0007622720040103344
    • Acidification Ap Mole Of H Equiv Maintenance B2 : 0
    • Acidification Ap Mole Of H Equiv Repair B3 : 0
    • Acidification Ap Mole Of H Equiv Replacement B4 : 0
    • Acidification Ap Mole Of H Equiv Operational Energy Use B6 : 0.006092917380671635
    • Acidification Ap Mole Of H Equiv End Of Life C1 C4 : 0.00558008849441316
    • Acidification Ap Mole Of H Equiv Benefits Loads Beyond System Boundaries D : -0.039306298625942364
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Associated Packaging Kg Of C BLB SysBound D : 0
    • Biogenic Carbon Content Of The Product Kg Of C Total Life Cycle : 0
    • Biogenic Carbon Content Of The Product Kg Of C Manufacturing A1 A3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Distribution A4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Installation A5 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Maintenance B2 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Repair B3 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Replacement B4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Operational Energy Use B6 : 0
    • Biogenic Carbon Content Of The Product Kg Of C End Of Life C1 C4 : 0
    • Biogenic Carbon Content Of The Product Kg Of C Benefits Loads Beyond System Boundaries D : 0
    • Climate Change Biogenics Kg Co2 Eq Total Life Cycle : 0.27646163732375695
    • Climate Change Biogenics Kg Co2 Eq Manufacturing A1 A3 : -0.6788580907206716
    • Climate Change Biogenics Kg Co2 Eq Distribution A4 : 0.00000305000781696786
    • Climate Change Biogenics Kg Co2 Eq Installation A5 : 0.5816134459837613
    • Climate Change Biogenics Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Biogenics Kg Co2 Eq Repair B3 : 0
    • Climate Change Biogenics Kg Co2 Eq Replacement B4 : 0
    • Climate Change Biogenics Kg Co2 Eq Operational Energy Use B6 : 0.006765223401187115
    • Climate Change Biogenics Kg Co2 Eq End Of Life C1 C4 : 0.36693800865166315
    • Climate Change Biogenics Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -0.08727173511726237
    • Climate Change Fossil Fuels Kg Co2 Eq Total Life Cycle : 18.739129500423406
    • Climate Change Fossil Fuels Kg Co2 Eq Manufacturing A1 A3 : 14.064831944402899
    • Climate Change Fossil Fuels Kg Co2 Eq Distribution A4 : 0.6003233261292253
    • Climate Change Fossil Fuels Kg Co2 Eq Installation A5 : 0.1262601673156069
    • Climate Change Fossil Fuels Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Repair B3 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Replacement B4 : 0
    • Climate Change Fossil Fuels Kg Co2 Eq Operational Energy Use B6 : 1.395057010627783
    • Climate Change Fossil Fuels Kg Co2 Eq End Of Life C1 C4 : 2.55265705194789
    • Climate Change Fossil Fuels Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -1.336936648070939
    • Climate Change Total Kg Co2 Eq Total Life Cycle : 19.01559535016932
    • Climate Change Total Kg Co2 Eq Manufacturing A1 A3 : 13.385976700823097
    • Climate Change Total Kg Co2 Eq Distribution A4 : 0.6003275034263549
    • Climate Change Total Kg Co2 Eq Installation A5 : 0.7078736145547192
    • Climate Change Total Kg Co2 Eq Maintenance B2 : 0
    • Climate Change Total Kg Co2 Eq Repair B3 : 0
    • Climate Change Total Kg Co2 Eq Replacement B4 : 0
    • Climate Change Total Kg Co2 Eq Operational Energy Use B6 : 1.40182223402897
    • Climate Change Total Kg Co2 Eq End Of Life C1 C4 : 2.9195952973361785
    • Climate Change Total Kg Co2 Eq Benefits Loads Beyond System Boundaries D : -1.4242083831882015
    • Components For Re Use Kg Total Life Cycle : 0
    • Components For Re Use Kg Manufacturing A1 A3 : 0
    • Components For Re Use Kg Distribution A4 : 0
    • Components For Re Use Kg Installation A5 : 0
    • Components For Re Use Kg Maintenance B2 : 0
    • Components For Re Use Kg Repair B3 : 0
    • Components For Re Use Kg Replacement B4 : 0
    • Components For Re Use Kg Operational Energy Use B6 : 0
    • Components For Re Use Kg End Of Life C1 C4 : 0
    • Components For Re Use Kg Benefits Loads Beyond System Boundaries D : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Total Life Cycle : 0.02948782693031219
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Manufacturing A1 A3 : 0.02948687223641655
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Distribution A4 : 0.00000049193704903159
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Installation A5 : 0.00000001813133142034
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Maintenance B2 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Repair B3 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Replacement B4 : 0
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb Operational Energy Use B6 : 0.00000032982091699664
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb End Of Life C1 C4 : 0.00000011480459819306
    • Depletion Of Abiotic Resources Elements Kg Equivalent Sb BLB SysBound D : -0.0006382295702348044
    • Depletion Of Abiotic Resources Fossil Fuels Mj Total Life Cycle : 320.212557533539
    • Depletion Of Abiotic Resources Fossil Fuels Mj Manufacturing A1 A3 : 262.2367512487704
    • Depletion Of Abiotic Resources Fossil Fuels Mj Distribution A4 : 11.00505613395285
    • Depletion Of Abiotic Resources Fossil Fuels Mj Installation A5 : 2.33939469606271
    • Depletion Of Abiotic Resources Fossil Fuels Mj Maintenance B2 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Repair B3 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Replacement B4 : 0
    • Depletion Of Abiotic Resources Fossil Fuels Mj Operational Energy Use B6 : 30.4138744356491
    • Depletion Of Abiotic Resources Fossil Fuels Mj End Of Life C1 C4 : 14.217481019103928
    • Depletion Of Abiotic Resources Fossil Fuels Mj Benefits Loads Beyond System Boundaries D : -29.04874741604894
    • Ecotoxicity Fresh Water Ctue Total Life Cycle : 10599.786848424015
    • Ecotoxicity Fresh Water Ctue Manufacturing A1 A3 : 10532.151054415197
    • Ecotoxicity Fresh Water Ctue Distribution A4 : 21.72400821270566
    • Ecotoxicity Fresh Water Ctue Installation A5 : 3.129432962852387
    • Ecotoxicity Fresh Water Ctue Maintenance B2 : 0
    • Ecotoxicity Fresh Water Ctue Repair B3 : 0
    • Ecotoxicity Fresh Water Ctue Replacement B4 : 0
    • Ecotoxicity Fresh Water Ctue Operational Energy Use B6 : 1.670117629527107
    • Ecotoxicity Fresh Water Ctue End Of Life C1 C4 : 41.11223520373268
    • Ecotoxicity Fresh Water Ctue Benefits Loads Beyond System Boundaries D : -10.281113668064961
    • Emission Of Fine Particles Incidence Of Diseases Total Life Cycle : 0.0000012611229216637
    • Emission Of Fine Particles Incidence Of Diseases Manufacturing A1 A3 : 0.00000116261858347997
    • Emission Of Fine Particles Incidence Of Diseases Distribution A4 : 0.0000000092140457691
    • Emission Of Fine Particles Incidence Of Diseases Installation A5 : 0.00000000531443036371
    • Emission Of Fine Particles Incidence Of Diseases Maintenance B2 : 0
    • Emission Of Fine Particles Incidence Of Diseases Repair B3 : 0
    • Emission Of Fine Particles Incidence Of Diseases Replacement B4 : 0
    • Emission Of Fine Particles Incidence Of Diseases Operational Energy Use B6 : 0.0000000451329743787
    • Emission Of Fine Particles Incidence Of Diseases End Of Life C1 C4 : 0.00000003884288767222
    • Emission Of Fine Particles Incidence Of Diseases BLB SysBound D : -0.00000073005677595985
    • Exported Energy Mj By Energy Vector Total Life Cycle : 0
    • Exported Energy Mj By Energy Vector Manufacturing A1 A3 : 0
    • Exported Energy Mj By Energy Vector Distribution A4 : 0
    • Exported Energy Mj By Energy Vector Installation A5 : 0
    • Exported Energy Mj By Energy Vector Maintenance B2 : 0
    • Exported Energy Mj By Energy Vector Repair B3 : 0
    • Exported Energy Mj By Energy Vector Replacement B4 : 0
    • Exported Energy Mj By Energy Vector Operational Energy Use B6 : 0
    • Exported Energy Mj By Energy Vector End Of Life C1 C4 : 0
    • Exported Energy Mj By Energy Vector Benefits Loads Beyond System Boundaries D : 0
    • Freshwater Eutrophication Kg P Eq Total Life Cycle : 0.00023249967808488197
    • Freshwater Eutrophication Kg P Eq Manufacturing A1 A3 : 0.00020814472637758154
    • Freshwater Eutrophication Kg P Eq Distribution A4 : 0.00000228492309624915
    • Freshwater Eutrophication Kg P Eq Installation A5 : 0.00000014928443633575
    • Freshwater Eutrophication Kg P Eq Maintenance B2 : 0
    • Freshwater Eutrophication Kg P Eq Repair B3 : 0
    • Freshwater Eutrophication Kg P Eq Replacement B4 : 0
    • Freshwater Eutrophication Kg P Eq Operational Energy Use B6 : 0.00000235453766871397
    • Freshwater Eutrophication Kg P Eq End Of Life C1 C4 : 0.00001956620650600155
    • Freshwater Eutrophication Kg P Eq Benefits Loads Beyond System Boundaries D : -0.00000172823841650203
    • Hazardous Waste Disposed Of Kg Total Life Cycle : 77.88121429164151
    • Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 77.73351571577001
    • Hazardous Waste Disposed Of Kg Distribution A4 : 0.0031103598226817557
    • Hazardous Waste Disposed Of Kg Installation A5 : 0.13743565512381123
    • Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0
    • Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 0.007152560925005644
    • Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -49.80918652258253
    • Human Toxicity Carcinogenic Effects Ctuh Total Life Cycle : 0.00000138122996543611
    • Human Toxicity Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000138009289250191
    • Human Toxicity Carcinogenic Effects Ctuh Distribution A4 : 0.00000000014630782454
    • Human Toxicity Carcinogenic Effects Ctuh Installation A5 : 0.00000000002273037632
    • Human Toxicity Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000000016274037341
    • Human Toxicity Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000080529435992
    • Human Toxicity Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000348061536512483
    • Human Toxicity Non Carcinogenic Effects Ctuh Total Life Cycle : 0.00000135114016548305
    • Human Toxicity Non Carcinogenic Effects Ctuh Manufacturing A1 A3 : 0.00000133647792565382
    • Human Toxicity Non Carcinogenic Effects Ctuh Distribution A4 : 0.00000000290141696303
    • Human Toxicity Non Carcinogenic Effects Ctuh Installation A5 : 0.00000000091976136838
    • Human Toxicity Non Carcinogenic Effects Ctuh Maintenance B2 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Repair B3 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Replacement B4 : 0
    • Human Toxicity Non Carcinogenic Effects Ctuh Operational Energy Use B6 : 0.00000000387897224473
    • Human Toxicity Non Carcinogenic Effects Ctuh End Of Life C1 C4 : 0.00000000696208925309
    • Human Toxicity Non Carcinogenic Effects Ctuh Benefits Loads Beyond System Boundaries D : -0.00000050727153179526
    • Impacts Related To Land Use Soil Quality Total Life Cycle : 0.13005080947865055
    • Impacts Related To Land Use Soil Quality Manufacturing A1 A3 : 0.08513899697544669
    • Impacts Related To Land Use Soil Quality Distribution A4 : 0.0031888552155023074
    • Impacts Related To Land Use Soil Quality Installation A5 : 0.0027133676880363843
    • Impacts Related To Land Use Soil Quality Maintenance B2 : 0
    • Impacts Related To Land Use Soil Quality Repair B3 : 0
    • Impacts Related To Land Use Soil Quality Replacement B4 : 0
    • Impacts Related To Land Use Soil Quality Operational Energy Use B6 : 0.02954427476091118
    • Impacts Related To Land Use Soil Quality End Of Life C1 C4 : 0.009465314838754004
    • Impacts Related To Land Use Soil Quality Benefits Loads Beyond System Boundaries D : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Total Life Cycle : 8.216355071593682
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Manufacturing A1 A3 : 6.689778421225001
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Distribution A4 : 0.02588479545357529
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Installation A5 : 0.046371435578683506
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Maintenance B2 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Repair B3 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Replacement B4 : 0
    • Ionizing Radiation Human Health Kbq Of U235 Equiv Operational Energy Use B6 : 1.285122854323384
    • Ionizing Radiation Human Health Kbq Of U235 Equiv End Of Life C1 C4 : 0.16919756501304029
    • Ionizing Radiation Human Health Kbq Of U235 Equiv BLB SysBound D : -0.7654726521346801
    • Marine Aquatic Eutrophication Kg Of N Equiv Total Life Cycle : 0.012471613420992329
    • Marine Aquatic Eutrophication Kg Of N Equiv Manufacturing A1 A3 : 0.009786307139763983
    • Marine Aquatic Eutrophication Kg Of N Equiv Distribution A4 : 0.00019370967286605023
    • Marine Aquatic Eutrophication Kg Of N Equiv Installation A5 : 0.00019202083526464035
    • Marine Aquatic Eutrophication Kg Of N Equiv Maintenance B2 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Repair B3 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Replacement B4 : 0
    • Marine Aquatic Eutrophication Kg Of N Equiv Operational Energy Use B6 : 0.0007783999915329658
    • Marine Aquatic Eutrophication Kg Of N Equiv End Of Life C1 C4 : 0.0015211757815646915
    • Marine Aquatic Eutrophication Kg Of N Equiv Benefits Loads Beyond System Boundaries D : -0.0010016242144019918
    • Materials For Energy Recovery Kg Total Life Cycle : 0
    • Materials For Energy Recovery Kg Manufacturing A1 A3 : 0
    • Materials For Energy Recovery Kg Distribution A4 : 0
    • Materials For Energy Recovery Kg Installation A5 : 0
    • Materials For Energy Recovery Kg Maintenance B2 : 0
    • Materials For Energy Recovery Kg Repair B3 : 0
    • Materials For Energy Recovery Kg Replacement B4 : 0
    • Materials For Energy Recovery Kg Operational Energy Use B6 : 0
    • Materials For Energy Recovery Kg End Of Life C1 C4 : 0
    • Materials For Energy Recovery Kg Benefits Loads Beyond System Boundaries D : 0
    • Materials For Recycling Kg Total Life Cycle : 0.5536131805997321
    • Materials For Recycling Kg Manufacturing A1 A3 : 0.08504721014212493
    • Materials For Recycling Kg Distribution A4 : 0
    • Materials For Recycling Kg Installation A5 : 0
    • Materials For Recycling Kg Maintenance B2 : 0
    • Materials For Recycling Kg Repair B3 : 0
    • Materials For Recycling Kg Replacement B4 : 0
    • Materials For Recycling Kg Operational Energy Use B6 : 0
    • Materials For Recycling Kg End Of Life C1 C4 : 0.4685659704576071
    • Materials For Recycling Kg Benefits Loads Beyond System Boundaries D : 0
    • Net Use Of Fresh Water M3 Total Life Cycle : 0.11801897079927638
    • Net Use Of Fresh Water M3 Manufacturing A1 A3 : 0.10863905965681477
    • Net Use Of Fresh Water M3 Distribution A4 : 0.0005846372956270851
    • Net Use Of Fresh Water M3 Installation A5 : 0.0001663581976834918
    • Net Use Of Fresh Water M3 Maintenance B2 : 0
    • Net Use Of Fresh Water M3 Repair B3 : 0
    • Net Use Of Fresh Water M3 Replacement B4 : 0
    • Net Use Of Fresh Water M3 Operational Energy Use B6 : 0.001930015213521714
    • Net Use Of Fresh Water M3 End Of Life C1 C4 : 0.006698900435629326
    • Net Use Of Fresh Water M3 Benefits Loads Beyond System Boundaries D : -0.04706931851390904
    • Non Hazardous Waste Disposed Of Kg Total Life Cycle : 5.656242823513997
    • Non Hazardous Waste Disposed Of Kg Manufacturing A1 A3 : 3.7193243194886003
    • Non Hazardous Waste Disposed Of Kg Distribution A4 : 0.06916655412822165
    • Non Hazardous Waste Disposed Of Kg Installation A5 : 0.016672643756437584
    • Non Hazardous Waste Disposed Of Kg Maintenance B2 : 0
    • Non Hazardous Waste Disposed Of Kg Repair B3 : 0
    • Non Hazardous Waste Disposed Of Kg Replacement B4 : 0
    • Non Hazardous Waste Disposed Of Kg Operational Energy Use B6 : 0.2264199705763508
    • Non Hazardous Waste Disposed Of Kg End Of Life C1 C4 : 1.6246593355643864
    • Non Hazardous Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.8199003683581609
    • Ozone Depletion Kg Equivalent Cfc 11 Total Life Cycle : 0.0000008891669152337
    • Ozone Depletion Kg Equivalent Cfc 11 Manufacturing A1 A3 : 0.00000084609352307672
    • Ozone Depletion Kg Equivalent Cfc 11 Distribution A4 : 0.00000000868673832917
    • Ozone Depletion Kg Equivalent Cfc 11 Installation A5 : 0.00000000453637003653
    • Ozone Depletion Kg Equivalent Cfc 11 Maintenance B2 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Repair B3 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Replacement B4 : 0
    • Ozone Depletion Kg Equivalent Cfc 11 Operational Energy Use B6 : 0.00000000503126979835
    • Ozone Depletion Kg Equivalent Cfc 11 End Of Life C1 C4 : 0.00000002481901399292
    • Ozone Depletion Kg Equivalent Cfc 11 Benefits Loads Beyond System Boundaries D : -0.00000027098049809273
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Total Life Cycle : 0.04297865794840458
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Manufacturing A1 A3 : 0.034776728526111744
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Distribution A4 : 0.000685510982772955
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Installation A5 : 0.0005385594498664671
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Maintenance B2 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Repair B3 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Replacement B4 : 0
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Operational Energy Use B6 : 0.002566780778983087
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv End Of Life C1 C4 : 0.004411078210670334
    • Photochemical Ozone Formation Kg Of Nmvoc Equiv Benefits Loads Beyond System Boundaries D : -0.005862394690882436
    • Radioactive Waste Disposed Of Kg Total Life Cycle : 0.001412293302854514
    • Radioactive Waste Disposed Of Kg Manufacturing A1 A3 : 0.001244707296093927
    • Radioactive Waste Disposed Of Kg Distribution A4 : 0.00005476010596819492
    • Radioactive Waste Disposed Of Kg Installation A5 : 0.00000695500082117549
    • Radioactive Waste Disposed Of Kg Maintenance B2 : 0
    • Radioactive Waste Disposed Of Kg Repair B3 : 0
    • Radioactive Waste Disposed Of Kg Replacement B4 : 0
    • Radioactive Waste Disposed Of Kg Operational Energy Use B6 : 0.00005259789789466586
    • Radioactive Waste Disposed Of Kg End Of Life C1 C4 : 0.00005327300207655078
    • Radioactive Waste Disposed Of Kg Benefits Loads Beyond System Boundaries D : -0.0003878440994673444
    • Terrestrial Eutrophication Mole Of N Equiv Total Life Cycle : 0.12588248220792803
    • Terrestrial Eutrophication Mole Of N Equiv Manufacturing A1 A3 : 0.09467644792877646
    • Terrestrial Eutrophication Mole Of N Equiv Distribution A4 : 0.0021255630321275875
    • Terrestrial Eutrophication Mole Of N Equiv Installation A5 : 0.0025276204732114517
    • Terrestrial Eutrophication Mole Of N Equiv Maintenance B2 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Repair B3 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Replacement B4 : 0
    • Terrestrial Eutrophication Mole Of N Equiv Operational Energy Use B6 : 0.009328698525549019
    • Terrestrial Eutrophication Mole Of N Equiv End Of Life C1 C4 : 0.017224152248263524
    • Terrestrial Eutrophication Mole Of N Equiv Benefits Loads Beyond System Boundaries D : -0.011768897299278722
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj TLC : 34.4206050889837
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 34.4206050889837
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0
    • Total Use Of NRE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Total Life Cycle : 339.89844655806525
    • Total Use Of Primary Energy During The Life Cycle Mj Manufacturing A1 A3 : 275.3257206288043
    • Total Use Of Primary Energy During The Life Cycle Mj Distribution A4 : 11.046788692230368
    • Total Use Of Primary Energy During The Life Cycle Mj Installation A5 : 2.540564103877629
    • Total Use Of Primary Energy During The Life Cycle Mj Maintenance B2 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Repair B3 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Replacement B4 : 0
    • Total Use Of Primary Energy During The Life Cycle Mj Operational Energy Use B6 : 36.05389361413643
    • Total Use Of Primary Energy During The Life Cycle Mj End Of Life C1 C4 : 14.93147951901652
    • Total Use Of PrE During The Life Cycle Mj BLB SysBound D : -29.636724405925136
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj TLC : 19.685882393511374
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Mfg A1 A3 : 13.088962749019021
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Dist A4 : 0.0417325582775163
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Inst A5 : 0.20116940781491868
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Maint B2 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Repair B3 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj Replament B4 : 0
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj OpEnergy B6 : 5.640019178487326
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj EoL C1 C4 : 0.7139984999125902
    • Total Use Of RE PrE Resources And PrE Resources Used As RawMats Mj BLB SysBound D : -0.5879769898761962
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 34.4206050889837
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 34.4206050889837
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of Non Renewable Primary Energy Resources Used As Raw Materials Mj End Of Life C1 C4 : 0
    • Use Of NRE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj TLC : 285.79195907557016
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Mfg A1 A3 : 227.81615279080157
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Dist A4 : 11.00505613395285
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Inst A5 : 2.33939469606271
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj OpEnergy B6 : 30.4138744356491
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj EoL C1 C4 : 14.217481019103928
    • Use Of NRE PrE Excluding NRE PrE Resources Used As RawMats Mj BLB SysBound D : -29.04874741604894
    • Use Of Non Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Non Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Non Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Non Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Non Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Non Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Non Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Total Life Cycle : 3.2597060758588237
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Manufacturing A1 A3 : 3.2597060758588237
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Distribution A4 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Installation A5 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Maintenance B2 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Repair B3 : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Replacement B4 : 0
    • Use Of RE PrE Resources Used As RawMats Mj OpEnergy B6 : 0
    • Use Of RE PrE Resources Used As RawMats Mj BLB SysBound D : 0
    • Use Of Renewable Primary Energy Resources Used As Raw Materials Mj Benefits Loads Beyond System Boundaries D : 0.4523294117647058
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj TLC : 16.42617631765255
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Mfg A1 A3 : 9.829256673160199
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Dist A4 : 0.0417325582775163
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Inst A5 : 0.20116940781491868
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Maint B2 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Repair B3 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj Replacement B4 : 0
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj OpEnergy B6 : 5.640019178487326
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj EoL C1 C4 : 0.7139984999125902
    • Use Of RE PrE Excluding RE PrE Resources Used As RawMats Mj BLB SysBound D : -1.040306401640902
    • Use Of Renewable Secondary Fuels Mj Total Life Cycle : 0
    • Use Of Renewable Secondary Fuels Mj Manufacturing A1 A3 : 0
    • Use Of Renewable Secondary Fuels Mj Distribution A4 : 0
    • Use Of Renewable Secondary Fuels Mj Installation A5 : 0
    • Use Of Renewable Secondary Fuels Mj Maintenance B2 : 0
    • Use Of Renewable Secondary Fuels Mj Repair B3 : 0
    • Use Of Renewable Secondary Fuels Mj Replacement B4 : 0
    • Use Of Renewable Secondary Fuels Mj Operational Energy Use B6 : 0
    • Use Of Renewable Secondary Fuels Mj End Of Life C1 C4 : 0
    • Use Of Renewable Secondary Fuels Mj Benefits Loads Beyond System Boundaries D : 0
    • Use Of Secondary Materials Kg Total Life Cycle : 0.22693456111764707
    • Use Of Secondary Materials Kg Manufacturing A1 A3 : 0.22693456111764707
    • Use Of Secondary Materials Kg Distribution A4 : 0
    • Use Of Secondary Materials Kg Installation A5 : 0
    • Use Of Secondary Materials Kg Maintenance B2 : 0
    • Use Of Secondary Materials Kg Repair B3 : 0
    • Use Of Secondary Materials Kg Replacement B4 : 0
    • Use Of Secondary Materials Kg Operational Energy Use B6 : 0
    • Use Of Secondary Materials Kg End Of Life C1 C4 : 0
    • Use Of Secondary Materials Kg Benefits Loads Beyond System Boundaries D : 0
    • Water Use M3 Eq Total Life Cycle : 5.036027076094782
    • Water Use M3 Eq Manufacturing A1 A3 : 4.666021871117811
    • Water Use M3 Eq Distribution A4 : 0.025109103346982613
    • Water Use M3 Eq Installation A5 : 0.007270896872650987
    • Water Use M3 Eq Maintenance B2 : 0
    • Water Use M3 Eq Repair B3 : 0
    • Water Use M3 Eq Replacement B4 : 0
    • Water Use M3 Eq Operational Energy Use B6 : 0.08282997970823561
    • Water Use M3 Eq End Of Life C1 C4 : 0.25479522504910046
    • Water Use M3 Eq Benefits Loads Beyond System Boundaries D : -2.0215893137629513
    • Air Pollution M3 Total Life Cycle : 0
    • Air Pollution M3 Manufacturing A1 A3 : 0
    • Air Pollution M3 Distribution A4 : 0
    • Air Pollution M3 Installation A5 : 0
    • Air Pollution M3 Maintenance B2 : 0
    • Air Pollution M3 Repair B3 : 0
    • Air Pollution M3 Replacement B4 : 0
    • Air Pollution M3 Operational Energy Use B6 : 0
    • Air Pollution M3 End Of Life C1 C4 : 0
    • Air Pollution M3 Benefits Loads Beyond System Boundaries D : 0
    • Water Pollution M3 Total Life Cycle : 0
    • Water Pollution M3 Manufacturing A1 A3 : 0
    • Water Pollution M3 Distribution A4 : 0
    • Water Pollution M3 Installation A5 : 0
    • Water Pollution M3 Maintenance B2 : 0
    • Water Pollution M3 Repair B3 : 0
    • Water Pollution M3 Replacement B4 : 0
    • Water Pollution M3 Operational Energy Use B6 : 0
    • Water Pollution M3 End Of Life C1 C4 : 0
    • Water Pollution M3 Benefits Loads Beyond System Boundaries D : 0
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer
    • AWG Gauge : AWG 12...AWG 2/0 aluminium, AWG 12...AWG 2/0 aluminium, AWG 14...AWG 2/0 copper, AWG 14...AWG 2/0 copper
    • Electrical Connection : lugs aluminium, lugs aluminium
    • Product Destination : NF panelboard, NF panelboard
    • Tightening Torque : 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0), 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-19
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : Out
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : No
    • ROHS EUR Status : Compliant with Exemptions
    • ROHS EUR Full Compliance Status : Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS EUR Full Compliance Status Id : PRO_ACTIVE_COMPLIANCE
    • China ROHS In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • WD Status : 1 - GSC certified
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Market Segmentation Id : COMMERCIAL
    • Market Segmentation : Commercial
    • H And D Domain : Safety
    • H And D Subrange : COM
    • H And D Enrichment Assignment : no
    • H And D Enrichment Function : MCB
    • H And D Enrichment Class 3 : Circuit Breakers
    • H And D Enrichment Class 4 : MCB UL 3P
    • Device Short Name : EGB
    • Energy Efficiency Optimized : False
    • Holding Current : 630 A
    • Module Type : E-Frame
    • Package Weight Lbs : 1.869 kg
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : miniature circuit-breaker
    • Range Of Product : 125 A Frame EDB-EGB-EJB
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 19 kg CO2 eq.
    • Pep Code : ENVPEP2510013EN
    • Pep Verification Date : 2025-11-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Functional Unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icn, and the tripping curve Cd if applicable, and, if applicable, the specific specifications, in the Household/Commercial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Unit : unit
    • Product Kit Identifier : N
    • Huella De Carbono De La Fase De Distribución A4 : 0.6 kg CO2 eq.
    • Huella De Carbono De La Fase De Fabricación A1 A A3 : 13 kg CO2 eq.
    • Huella De Carbono De La Fase De Fin De Vida C1 A C4 : 3 kg CO2 eq.
    • Huella De Carbono De La Fase De Instalación A5 : 0.7 kg CO2 eq.
    • Huella De Carbono De La Fase De Uso B2 B3 B4 B6 : 1 kg CO2 eq.
  • Environment Attributes Main
    • EU ROHS Directive : Compliant By Exemption​, Pro-active compliance (Product out of EU RoHS legal scope)
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Mercury Free : Yes
    • Carbon Footprint : 19.01559535016932
    • Environmental Disclosure : ENVPEP2510013EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2510013EN
    • Pep Verification Date : 2025-11-01
    • PCR Version : PEP-PCR-ed4-2021 09 06
    • PSR Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : miniature circuit-breaker
    • Range Of Product : 125 A Frame EDB-EGB-EJB
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Compliance : TAA