SQUARE D

Transformer, dry type, DOE 2016, 75kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 20M, 115C rise

Transformer, dry type, DOE 2016, 75kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 20M, 115C rise

SQDEXN75T3HF EXN75T3HF 785901436577
8470.09 / EA
http://schema.org/OutOfStock
  • Depth: 697 mm
  • Material: Aluminum
  • Primary Voltage: 480 V
  • Temperature Rise: 115 °C, 220 °C
EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 75kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 115 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.60% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
QTY
  • Features
  • Specifications
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=EXN75T3HF&p_File_name=EXN75T3HF.DWG, https://download.schneider-electric.com/files?p_Doc_Ref=EXN75T3HF&p_File_name=EXN75T3HF.DXF
  • Conformance Attributes
    • Standards : UL 1561, CSA C22.2 No 47, NEMA ST-20
  • Complementary Attributes
    • Rated Operational Power In Va : 75 kVA
    • Ipk Rated Peak Withstand Current : 4.11 kA
    • Uimp Rated Impulse Withstand Voltage : 10 kV
  • Important Information Attributes
    • Continuous Thermal Current Rating Factor : 679 16.6 %, 913 25 %, 2180 50 %, 4300 75 %, 7268 100 %
    • Electrical Connection : 2 Hole Nema Pad secondary 11.1 mm, 4 Hole Nema Pad sec - XO 11.1 mm, 4 Hole Nema Pad primary 11.1 mm
    • Mounting Support : floor, floor, with 7400FMB, ceiling, with 7400CMB18M19M20M, wall, with 7400WMB18M19M20M
    • Noise Level : 44 dB, 6 dB NEMA ST-20
    • Number Of Tap Offs : 2 2.5 % FCAN, 4 2.5 % FCBN
    • Tap Loss : 144 no load (core loss), 1979 load loss (coil loss)
    • Temperature Rise : 115 °C, 220 °C insulated
    • Carbon Footprint Of The Distribution Phase A4 : 45.101120493786155, 45 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 510 kg CO2 eq., 510.11049504980275
    • Carbon Footprint Of The Installation Phase A5 : 0, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 1 598 kg CO2 eq., 1597.5463409360657
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 20 853 kg CO2 eq., 20853.36168335877
    • Medium Desc : Transformer, dry type, DOE 2016, 75kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 20M, 115C rise
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-02-04
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : Y
    • Device Type : Transformer - dry
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PSIBS
    • Average Life Duration : 25 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Box Number : 20M
    • Device Application : low voltage electrical distribution
    • Device Short Name : DOE 2016
    • Efficiency : 98.67 % at 35 % load factor , 75.0 °C
    • Halogen Free Status : Halogen free plastic parts product
    • Inrush Current : 777 A
    • Material : aluminium
    • Network Frequency : 60 Hz
    • Number Of Mounting Holes : 4 Ø: 13 mm
    • Percentage Impedance Voltage : 5.07 %
    • Percentage Reactance : 4.41 %
    • Phase : 3 phase
    • Primary Operational Current : 90.21-90.21 A 208.18 A 75 kVA
    • Primary Voltage : 480 V delta
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : transformer
    • Range Of Product : Square D
    • Returnability : Yes
    • Secondary Voltage : 208Y/120 V
    • Software Version : v6.2.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 23 006 kg CO2 eq.
    • Transformer Type : energy efficient
    • Type Of Cooling : natural convection
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ipk Rated Peak Withstand Current : 4.11 kA
    • Pep Code : ENVPEP1604028EN
    • Database Version : 2024-11
    • Pep Verification Date : 2025-02-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.To step down a distribution line voltage of 75kVA to voltage levels used by the end customer at the energy efficiency requirements defined by the DOE for 20 years.
    • Functional Unit Unit : Unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model Installation A5 2 : Electricity origin
    • Energy Model Use B6 2 : Electricity origin
    • Energy Model End Of Life C1 C4 2 : Electricity origin
    • Height Nominal : 851 mm
    • Width Nominal : 764 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Take Back : Nej
    • Declare : Red list free
    • Reach Free Shvc : Yes
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 23006.119639838424
    • Ambient Air Temperature For Operation : 40-40 °C
    • Average Ambient Air Temperature For Operation : 30 °C
    • Environmental Disclosure : ENVPEP1604028EN
    • Eu Rohs Directive : Compliant
    • Halogen Content Performance : Halogen free plastic parts product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1604028EN
    • Pep Verification Date : 2025-02-01
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : transformer
    • Range Of Product : Square D
  • Input Attributes
    • Efficiency : 98.67 % at 35 % load factor , 75.0 °C
  • Specifications
    • Depth : 697 mm