Current limiter,TeSys Deca Frame 2,32A/690V,activation 1.5kA,at top of GV2ME/GV2P/GV2RT with screw clamp connections

MANUAL STARTER CURRENT LIMITER

SQDGV1L3 GV1L3 3389110209952
118.66 / EA
http://schema.org/OutOfStock
  • Warranty Length: 18 mth
TeSys GV short circuit current limiter block for motor circuit breakers GV2L/LE/P/ME/RT. It increases the ability of the circuit breaker to withstand a short circuit current from 50 kA to 100/130kA@400 V. To be mounted on top of a GV2 motor circuit breaker. It conforms to RoHS/REACh regulation.
QTY
  • Product Description
  • Features
  • Specifications
TeSys GV short circuit current limiter block for motor circuit breakers GV2L/LE/P/ME/RT. It increases the ability of the circuit breaker to withstand a short circuit current from 50 kA to 100/130kA@400 V. To be mounted on top of a GV2 motor circuit breaker. It conforms to RoHS/REACh regulation.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Ie Rated Operational Current : 32 A
    • Ue Rated Operational Voltage : 690 V AC 50/60 Hz
    • Ui Rated Insulation Voltage : 690 V AC 50/60 Hz IEC 60947-1
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Range Of Product : TeSys GV2, TeSys Deca
    • Connections Terminals : screw clamp terminals 2 x 1.5-10 mm² flexible without cable end, screw clamp terminals 2 x 1.5-4 mm² flexible with cable endscrew clamp terminals 1 x 1.5-25 mm² rigid, screw clamp terminals 2 x 1.5-10 mm² rigid, screw clamp terminals 1 x 1.5-25 mm² flexible without cable end, screw clamp terminals 1 x 1.5-16 mm² flexible with cable end
    • Carbon Footprint Of The Distribution Phase A4 : 0.04318814490615565, 0 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 0.3 kg CO2 eq., 0.3460838621846032
    • Carbon Footprint Of The Installation Phase A5 : 0.01627033056179283, 0 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 0.8 kg CO2 eq., 0.7913274970007742
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 40 kg CO2 eq., 40.392
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-03-25
    • Return Indicator : Y
    • Stocking Flag : N
    • Stock Policy : 2
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Use Carbon Footprint : 40.392
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 2026
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Function Of Module : increasing the breaking capacity of a circuit breaker
    • Mounting Location : on top of the circuit breaker
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : current limiting module
    • Range : TeSys
    • Returnability : Yes
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Tightening Torque : 2.2 N.m
    • Total Lifecycle Carbon Footprint : 42 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Accessory Separate Part Category : protection accessory
    • Ie Rated Operational Current : 32 A
    • Ith Conventional Free Air Thermal Current : 63 A IEC 60947-1
    • Warranty In Months : 18
    • Database Version : 2022-01
    • Pep Verification Date : 2023-10-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional-unit Description : Protect during 20 years the installation against overloads and short-circuits in circuit with assigned voltage 690V AC and rated current 4A. This protection is ensured in accordance with the following parameters:& 10- Number of poles 3p& 10- Rated breaking capacity 3KA
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unit
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 98.55
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; UE-27
    • Offer Owner Code : 190788
    • Pn : 1
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 40.338
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 40.392
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 1029.1
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 435
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 60.057
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 5.8116
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 1226.7
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 197.61
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1029.1
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 197.61
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Product Compatibility : GV2RT, GV2ME, GV2P, GV2L
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold, Free of Substances of Very High Concern above the threshold
    • Take Back : No
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 41.58886983465333
    • Eu Rohs Directive : Compliant
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Pep Verification Date : 2023-10-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Range Of Product : TeSys GV2, TeSys Deca
    • Product Or Component Type : current limiting module
  • ETIM
    • ETIM 8 : EC000239
    • ETIM 9 : EC000239
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil, France, United Kingdom, United States