Control box, Cabling components, ZPA M12 connection, sensor and actuator connection IP67

CONTROL BOX, CABLING COMPONENT

SQDXZBA41D1M12 XZBA41D1M12 3389119621212
227.77 / EA
http://schema.org/OutOfStock
  • Enclosure Material: Plastic
  • Net Weight: 0.18 kg
  • Storage Temperature: -25-85 °C
  • Warranty Length: 18 mth
QTY
  • Specifications
  • Specifications
    • Range Of Product : Telemecanique Cabling components
    • Product Or Component Type : control box
    • Product Specific Application : conveying applications
    • Enclosure Material : Plastic
    • Product Compatibility : electronic sensors
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Electrical Connection : 1 male connector M12 A coding, 4 ways downstream link I5 || 1 female connector M12 A coding, 4 ways output control relay I4 || 1 female connector M12 A coding, 4 ways sensor input I3 || 1 female connector M12 A coding, 4 ways transmittor supply I2 || 1 female connector M12 A coding, 4 ways upstream link I1
    • [Ue] Rated Operational Voltage : 24 V DC
    • Fixing Mode : by 2 screws
    • Discrete Input Voltage : 24 V DC
    • Net Weight : 0.18 kg
    • Discrete Output Current : 45 mA I3) || 200 mA I4)
    • Input/Output Number : 5
    • Discrete Input Type : PNP I3 || NPN I4
    • Local Signalling : for downstream load 1 LED (green) || for output relay state 1 LED (yellow) || for input status 1 LED (green) || for wake up 1 LED (red) || for upstream load 1 LED (yellow)
    • Operating Position : any position
    • Sensor Power Supply : 18-30 V 280 mA overload, short-circuit and reverse polarity protection
  • Offer Sustainability
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
  • Environment
    • Ambient Air Temperature For Operation : -10-60 °C
    • Electromagnetic Compatibility : electrostatic discharge immunity test 4 kV on contact) EN/IEC 61000-4-2 || electrostatic discharge immunity test 8 kV in air) EN/IEC 61000-4-2 || susceptibility to electromagnetic fields 1 V/m 2...2.7 GHz) EN/IEC 61000-4-3 || susceptibility to electromagnetic fields 10 V/m 80...2000 MHz) EN/IEC 61000-4-3 || electrical fast transient/burst immunity test 2 kV power supply) EN/IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV input/output) EN/IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV shielded cable) EN/IEC 61000-4-4 || 1.2/50 µs shock waves immunity test 0.5 kV power supply (common mode)) EN/IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 1 kV power supply (differential mode)) EN/IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 0.5 kV unshielded links (common mode)) EN/IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 1 kV unshielded links (differential mode)) EN/IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 0.5 kV shielded links (common mode)) EN/IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 1 kV shielded links (differential mode)) EN/IEC 61000-4-5 || conducted RF disturbances 10 V 150 kHz...80 MHz) EN/IEC 61000-4-6
    • Shock Resistance : 30 gn 11 ms IEC 60068-2-27
    • Marking : CE
    • Vibration Resistance : +/- 1 mm 2-13.2 Hz)GL || +/- 1 mm 2-36 Hz)EN/IEC 60068-2-6 || 0.7 gn 13.2-100 Hz)GL || 5 gn 36-150 Hz)EN/IEC 60068-2-6
    • Ip Degree Of Protection : IP67 conforming to IEC 60529
    • Pollution Degree : 3 EN/IEC 60664
    • Ambient Air Temperature For Storage : -25-85 °C
    • Relative Humidity : 5-95 % without condensation or dripping water