SQUARE D

Contactor, Type L, multipole lighting, electrically held, 30A, 2 pole, 600V, 277VAC 60Hz coil, NEMA 1 [TAA]

Contactor, Type L, multipole lighting, electrically held, 30A, 2 pole, 600V, 277VAC 60Hz coil, NEMA 1 [TAA]

SQD8903LG20V04 8903LG20V04 785901625643
463.05 / EACH
http://schema.org/OutOfStock
  • Depth: 153 mm
  • Warranty Length: 18 mth
8903L multipole lighting contactors are for lighting control applications. 8903L lighting contactors are available in either mechanically held or electrically held versions. This is an electrically held device. Can switch up to 30 A fluorescent and 20 A tungsten lighting loads. The contacts are field convertible from NO to NC. This device 2 pole device has 2 NO contacts. Supplied with a 277 VAC 60 Hz interchangeable operating coil but other coils are available in a wide variety of common voltages up to 600VAC. Contactor is in a NEMA 1 painted sheet steel enclosure, but a variety of other enclosure types are available. Coil and contacts are easily replaced. Enclosure is 12.69 inches tall, 7.81 inches wide and 6.03 inches deep. 8903L lighting contactors are UL Listed and CSA Certified.
QTY
  • Product Description
  • Specifications
8903L multipole lighting contactors are for lighting control applications. 8903L lighting contactors are available in either mechanically held or electrically held versions. This is an electrically held device. Can switch up to 30 A fluorescent and 20 A tungsten lighting loads. The contacts are field convertible from NO to NC. This device 2 pole device has 2 NO contacts. Supplied with a 277 VAC 60 Hz interchangeable operating coil but other coils are available in a wide variety of common voltages up to 600VAC. Contactor is in a NEMA 1 painted sheet steel enclosure, but a variety of other enclosure types are available. Coil and contacts are easily replaced. Enclosure is 12.69 inches tall, 7.81 inches wide and 6.03 inches deep. 8903L lighting contactors are UL Listed and CSA Certified.
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_3D-simplified-ec.stp, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-back.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-back.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-bottom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-bottom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-front.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-front.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-isometric.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-isometric.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-left.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-left.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-right.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-right.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-top.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPP0003049_3D-CAD&p_File_name=MCADPP0003049_2D-top.dxf
  • Conformance Attributes
    • Product Certifications : UL Listed, CSA
  • Complementary Attributes
    • Line Rated Current : 20-20 A tungsten, 30-30 A fluorescent
    • Control Circuit : separate control circuit
    • Uc Control Circuit Voltage : 277 V AC 60 Hz
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Carbon Footprint Of The Distribution Phase A4 : 3.6561124679787915, 4 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 6 kg CO2 eq., 6.2072460296693865
    • Carbon Footprint Of The Installation Phase A5 : 0.5984996043978802, 0.6 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 34 kg CO2 eq., 33.529999204306606
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 364 kg CO2 eq., 363.82168441250667
    • Medium Desc : Contactor, Type L, multipole lighting, electrically held, 30A, 2 pole, 600V, 277VAC 60Hz coil, NEMA 1 [TAA]
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-19
    • Global Commercial Status : Commercialised
    • Return Indicator : N
    • Stocking Flag : Y
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Control Circuit : separate control circuit
    • Control Type : no control units
    • Electrical Connection : screw-clamp terminals
    • Energy Efficiency Optimized : False
    • Halogen Free Status : Halogen free plastic parts product
    • Hold In Power Consumption In Va : 30-30 VA 60 Hz
    • Inrush Power In Va : 150-150 VA 60 Hz
    • Local Signalling : no indicator
    • Poles Description : 2P 2 NO
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : Electrically Held Lighting Contactor
    • Range Of Product : 8903L
    • Returnability : No
    • Software Version : v6.2.5-6
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 408 kg CO2 eq.
    • Pep Code : ENVPEP1407018EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-10-15
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Height Nominal : 322 mm
    • Width Nominal : 198 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Take Back : No
    • Reach Free Shvc : Yes
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 407.8135417188593
    • Environmental Disclosure : ENVPEP1407018EN
    • Eu Rohs Directive : Compliant
    • Halogen Content Performance : Halogen free plastic parts product
    • Nema Degree Of Protection : NEMA 1 painted sheet steel surface
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1407018EN
    • Pep Verification Date : 2025-10-15
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : Electrically Held Lighting Contactor
    • Range Of Product : 8903L
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Compliance : TAA Compliant
    • Depth : 153 mm