SQUARE D

Contactor, Tesys Deca Advanced, 3P(3NO), 75hp at 480V, 115A, 100-250V AC/DC coil, Everlink

CTR DECA 115A 3P 100-250V ACDC

SQDLC1D115AKUE 3606486976975
753.34 / EA
http://schema.org/OutOfStock
  • Depth: 155 mm
TeSys Deca Advanced contactor, 3 poles (3NO) for motor control applications up to 75hp at 480V, 160A general purpose It is equipped with a 100-250V AC/DC wide-band electronic coil that has lower power consumption, along with integrated 1NO+1NC auxiliary contacts. It can be installed in any orientation, and LRD43 could be directly mounted below contactor. The operating temperature range is between -40°C and 70°C, and it can be installed at altitudes of up to 3000m without derating. It is designed for demanding applications with improved performance under harsh environment including salt-mist, dust and high shock. The dimension is 152mm x 97mm x 155mm (H x W x D). Compact size enables panel space savings. Simple wiring with all front access to control circuit enhances accessibility and safety.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca Advanced contactor, 3 poles (3NO) for motor control applications up to 75hp at 480V, 160A general purpose It is equipped with a 100-250V AC/DC wide-band electronic coil that has lower power consumption, along with integrated 1NO+1NC auxiliary contacts. It can be installed in any orientation, and LRD43 could be directly mounted below contactor. The operating temperature range is between -40°C and 70°C, and it can be installed at altitudes of up to 3000m without derating. It is designed for demanding applications with improved performance under harsh environment including salt-mist, dust and high shock. The dimension is 152mm x 97mm x 155mm (H x W x D). Compact size enables panel space savings. Simple wiring with all front access to control circuit enhances accessibility and safety.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=LC1D115AKUE_3D-CAD
  • Conformance Attributes
    • Product Certifications : CB Scheme, CCC, cULus, CE, UKCA, EU-RO-MR by DNV-GL
    • Standards : EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, JIS C8201-4-1, JIS C8201-5-1, GB/T 14048.4, GB/T 14048.5
  • Complementary Attributes
    • Control Circuit Type : AC 50/60 Hz, AC 50/60 Hz, DC
    • Control Circuit Voltage Limits : 0.8 Uc Min...1.1 Uc Max (-40-60 °C):operational AC/DC, 0.1 Uc Max (-40-60 °C):drop-out AC/DC
    • Irms Rated Making Capacity : 1560 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
    • Maximum Horse Power Rating : 30 hp at 200/208 V 60 Hz, 40 hp at 230/240 V 60 Hz, 75 hp at 460/480 V 60 Hz, 100 hp at 575/600 V 60 Hz
    • Maximum Operating Rate : 2400 cyc/h at 60 °C, 3600 cyc/h at Uc at 20 ºC
    • Icw Rated Short Time Withstand Current : 350 A 40 °C - 10 min for power circuit, 600 A 40 °C - 1 min for power circuit, 1280 A 40 °C - 10 s for power circuit, 1800 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Ie Rated Operational Current : 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • Uc Control Circuit Voltage : 100...250 V, 100...250 V AC 50/60 Hz, 100...250 V DC
    • Ue Rated Operational Voltage : power circuit <= 1000 V AC 16.67...400 Hz, power circuit <= 300 V DC
    • Ui Rated Insulation Voltage : signalling circuit 600 V CSA, signalling circuit 600 V UL, power circuit 600 V CSA, power circuit 600 V UL, power circuit 1000 V IEC 60947-4-1, signalling circuit 690 V IEC 60947-1
    • Maximum Motor Phase Current : 115 A
    • Minimum Switching Current : 5 mA for signalling circuit
    • Minimum Switching Voltage : 17 V for signalling circuit
    • Rated Breaking Capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
    • Uimp Rated Impulse Withstand Voltage : 8 kV IEC 60947
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Associated Fuse Rating : 125 A aM at <= 440 V for power circuit, 100 A aM at <= 690 V for power circuit, 200 A gG at <= 690 V for power circuit, 10 A gG for signalling circuit, 0.2 A gG for control circuit
    • Contactor Application : motor control, resistive load
    • Electrical Durability : 1 Mcycles 115 A AC-3 <= 440 V, 1 Mcycles 115 A AC-3e <= 440 V, 0.5 Mcycles 200 A AC-1 <= 440 V
    • Insulation Resistance : > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit, > 10 MOhm for signalling circuit
    • Mechanical Robustness : vibrations contactor open 2 Gn, 5...300 Hz) IEC 60068-2-6, vibrations contactor closed 4 Gn, 5...300 Hz) IEC 60068-2-6, shocks contactor open 10 Gn for 11 ms) IEC 60068-2-27, shocks contactor closed 15 Gn for 11 ms) IEC 60068-2-27
    • Motor Power Kw : 55 kW at 400 V AC 50/60 Hz (AC-3e), 59 kW at 415 V AC 50/60 Hz (AC-3e), 59 kW at 440 V AC 50/60 Hz (AC-3e), 75 kW at 500 V AC 50/60 Hz (AC-3e), 80 kW at 690 V AC 50/60 Hz (AC-3e), 65 kW at 1000 V AC 50/60 Hz (AC-3e), 55 kW at 400 V AC 50/60 Hz (AC-4), 55 kW at 440 V AC 50/60 Hz (AC-4), 65 kW at 690 V AC 50/60 Hz (AC-4), 30 kW at 230 V AC 50/60 Hz (AC-3), 55 kW at 400 V AC 50/60 Hz (AC-3), 59 kW at 415 V AC 50/60 Hz (AC-3), 59 kW at 440 V AC 50/60 Hz (AC-3), 75 kW at 500 V AC 50/60 Hz (AC-3), 80 kW at 690 V AC 50/60 Hz (AC-3), 65 kW at 1000 V AC 50/60 Hz (AC-3), 30 kW at 230 V AC 50/60 Hz (AC-3e), 30 kW at 230 V AC 50/60 Hz (AC-4), 63 kW at 500 V AC 50/60 Hz (AC-4), 50 kW at 1000 V AC 50/60 Hz (AC-4)
    • Non Overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
    • Operating Time : 25...90 ms opening, 20...90 ms closing
    • Power Dissipation Per Pole : 6 W AC-3, 6 W AC-3e, 22 W AC-1
    • Safety Reliability Level : B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
    • Tightening Torque : power circuit 12 N.m connector hexagonal 4 mm, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2
    • Utilisation Category : AC-3, AC-3e, AC-1, AC-4, DC-1, DC-3, DC-5
    • Connections Terminals : power circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 10-50 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, connector
    • Icw Rated Short Time Withstand Current : 350 A 40 °C - 10 min for power circuit, 600 A 40 °C - 1 min for power circuit, 1280 A 40 °C - 10 s for power circuit, 1800 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
    • Ie Rated Operational Current : 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • Carbon Footprint Of The Distribution Phase A4 : 0.3996432973200851, 0.4 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 5.454633408348155, 5 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase A5 : 0.3 kg CO2 eq., 0.2902760592674699
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 26 kg CO2 eq., 25.87910123592437
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 280 kg CO2 eq., 280.0538148162723
    • Medium Desc : Contactor, Tesys Deca Advanced, 3P(3NO), 75hp at 480V, 115A, 100-250V AC/DC coil, Everlink
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-12-03
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Country Of Origin 6 : US
    • Stocking Flag : N
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2408027
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Average Impedance : 0.45 mOhm - Ith 200 A 50 Hz for power circuit
    • Coil Technology : built-in bidirectional peak limiting diode suppressor
    • Compatibility Code : LC1D
    • Device Short Name : LC1D
    • Fire Resistance : 850 °C IEC 60695-2-11
    • Halogen Free Status : Halogen free plastic parts product
    • Heat Dissipation : 1.1-1.1 W at 20 °C
    • Hold In Power Consumption In Va : 8-8 VA (at 20 °C)
    • Hold In Power Consumption In W : 4.5-4.5 W 20 °C
    • Inrush Power In Va : 170-170 VA (at 20 °C)
    • Inrush Power In W : 105-105 W 20 °C)
    • Mechanical Durability : 8 Mcycles
    • Mounting Support : plate
    • Overvoltage Category : III
    • Pole Contact Composition : 3 NO
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : contactor
    • Protective Treatment : noneIEC 60068-2-30
    • Range : TeSys Deca
    • Range Of Product : TeSys Deca Advanced
    • Returnability : Yes
    • Signalling Circuit Frequency : 16.67...400 Hz
    • Software Version : v6.1
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 312 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Ith Conventional Free Air Thermal Current : 200 A (at 60 °C) for power circuit
    • Control Circuit Voltage : 100...250 V
    • Inf Motor Phase Current : 115 A
    • Pep Code : ENVPEP2408027
    • Database Version : 2023-02
    • Pep Verification Date : 2025-08-11
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : extrapolated product
    • Functional Unit Description : Establish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts X, a rated voltage of Ue, a rated current Ie, a control circuit voltage Uc, with Np poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 yearsEstablish and cut off the supply of a downstream installation from an electrical and/or mechanical control characterised by the composition of the poles or type of contacts 3O, a rated voltage up to 1000V, a rated current AC3 115A, a control circuit voltage 100-250VAC/DC, with 3 poles, and if applicable the specific specifications, in the Household/Commercial or Industrial application areas, according to the appropriate use scenario, and during the reference service life of the product of 20 years
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : China, CN
    • Energy Model Installation A5 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Energy Model End Of Life C1 C4 2 : Electricity Mix; Low voltage; 2018; Europe, EU-27
    • Height Nominal : 152 mm
    • Width Nominal : 97 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Climatic Withstand : IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
    • Permissible Ambient Air Temperature Around The Device : -40-60 °C operation, -40-60 °C operation, -60-80 °C storage, -60-80 °C storage, -40-60 °C operation, -40-60 °C operation, 60-70 °C with derating, -60-80 °C storage, -60-80 °C storage
    • Take Back : Nej
    • Halogene Performance : Halogen free plastic parts product
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 312.0774688171324
    • Circularity Profile : ENVEOLI2408027
    • Environmental Disclosure : ENVPEP2408027
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts product
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2408027
    • Pep Verification Date : 2025-08-11
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : contactor
    • Range Of Product : TeSys Deca Advanced
  • ETIM
    • ETIM 8 : EC000066
    • ETIM 9 : EC000066
  • Specifications
    • Country of Origin : Indonesia, Philippines
    • Depth : 155 mm