Complete control station, Harmony XALD, dark grey, 2 green flush pushbuttons, 22mm

PUSHBUTTON ENCLOSURE FWD & REV

SQDXALD251H29H7 XALD251H29H7 3606480502705
94.14 / EA
http://schema.org/OutOfStock
  • Cable Entry: 14-14 mm, 20 12-12 mm
  • Country of Origin: France
  • Warranty Length: 18 mth
This Harmony XALD, is a complete ready to use control station for two functions. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP66, IP67, IP69, IP69K, making it ideal for operation in harsh environments. This control station provides a good resistance to chemical agents, thanks to its electrical double insulation. Its wide range of operating temperatures from -40°C to 70°C allows versatility in usage of product. It provides a polycarbonate double insulated enclosure with a light grey (RAL 7035) base of enclosure and a dark grey (RAL 7016) cover. This control station is ideally suited for industrial, buildings, and infrastructure applications. This control station complies with IEC, UL, CSA standards, as well as CE marking. It is also UL listed and CSA certified. It is compatible with the Harmony XB5 range of control and signaling units, providing a wide choice of circular and square heads
QTY
  • Product Description
  • Specifications
This Harmony XALD, is a complete ready to use control station for two functions. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP66, IP67, IP69, IP69K, making it ideal for operation in harsh environments. This control station provides a good resistance to chemical agents, thanks to its electrical double insulation. Its wide range of operating temperatures from -40°C to 70°C allows versatility in usage of product. It provides a polycarbonate double insulated enclosure with a light grey (RAL 7035) base of enclosure and a dark grey (RAL 7016) cover. This control station is ideally suited for industrial, buildings, and infrastructure applications. This control station complies with IEC, UL, CSA standards, as well as CE marking. It is also UL listed and CSA certified. It is compatible with the Harmony XB5 range of control and signaling units, providing a wide choice of circular and square heads
  • Environment
    • Product Certifications : UL Listed || CSA
    • Ik Degree Of Protection : IK03 conforming to IEC 62262
    • Ambient Air Temperature For Operation : -40-70 °C
    • Standards : UL 508 || JIS C8201-5-1 || IEC 60947-5-1 || CSA C22.2 No 14 || IEC 60947-1 || IEC 60947-5-4 || IEC 60947-5-5 || JIS C8201-1
    • Shock Resistance : 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
    • Vibration Resistance : 5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6
    • Ip Degree Of Protection : IP66 IEC 60529 || IP67 || IP69 || IP69K
    • Ambient Air Temperature For Storage : -40-70 °C
    • Nema Degree Of Protection : NEMA 13 || NEMA 4X
    • Electrical Shock Protection Class : class II IEC 60536
    • Protective Treatment : TH
  • Contractual warranty
    • Warranty : 18 months
  • Environmental data
    • Rohs Exemption Information : Yes
    • Packaging Made With Recycled Cardboard : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1806010EN
    • Packaging Without Single Use Plastic : Yes
    • Toxic Heavy Metal Free : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Reach Free Of Svhc : Yes
    • Weee : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Minimum Percentage Of Recycled Plastic Content : 0
    • Circularity Profile : ENVEOLI1806010EN
    • Take-Back : No
    • Sustainable Packaging : Yes
    • Eu Rohs Directive : Pro-active compliance (Product out of EU RoHS legal scope)
    • Carbon Footprint (Kg Co2 Eq, Total Life Cycle) : 1.6933774735
  • Complementary
    • Short-Circuit Protection : 10 A cartridge fuse gG IEC 60947-5-1
    • Contacts Material : silver alloy (Ag/Ni)
    • [Ith] Conventional Free Air Thermal Current : 10 A IEC 60947-5-1
    • Cable Entry : 2 knock-outs for cable entry 14-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
    • [Uimp] Rated Impulse Withstand Voltage : 6 kV IEC 60947-1
    • Resistance To High Pressure Washer : 7000000 Pa 55 °C 0.1 m
    • Electrical Durability : 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
    • Connections - Terminals : screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
    • [Ui] Rated Insulation Voltage : 600 V 3)IEC 60947-1
    • [Ie] Rated Operational Current : 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 3 A 240 V, AC-15, A600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1
    • Mechanical Durability : 5000000 cycles
    • Electrical Reliability : λ < 10exp(-6) 5 V 1 mA IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA IEC 60947-5-4
    • Tightening Torque : 0.8-1.2 N.m IEC 60947-1
    • Shape Of Screw Head : cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
  • Specifications
    • Country of Origin : France
    • Control Station Application : two functions
    • Product Destination : for XB5 Ø 22 mm control and signalling units
    • Range Of Product : Harmony XALD
    • Colour Of Base Of Enclosure : light grey RAL 7035)
    • Product Or Component Type : complete control station
    • Material : polycarbonate
    • Colour Of Cover : dark grey RAL 7016)
    • Device Short Name : XALD