Circuit breaker, PowerPacT P, 250A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 5.0A, 80%, ABC

MOLDED CASE CIRCUIT BREAKER 60

SQDPGA36025U43A PGA36025U43A 785901686286
17410.34 / EACH
http://schema.org/OutOfStock
  • Certifications: CSA, NOM, UL
  • Depth: 8.05 in
  • Height: 12.86 in
  • Line Rated Current: 250-250 A
  • Mounting Type: I-Line Bracket)
  • Net Weight: 32 lb
  • Standard: CSA, IEC 60947-2, NEMA, NOM-003-SCFI-2000, UL
  • Storage Temperature: -50-85 °C
  • Strip Length: 25 mm
  • Warranty Length: 18 mth
  • Width: 8.27 in
Providing unparalleled performance and control, the P-frame circuit breakers features the exclusive Micrologic electronic trip units, which allow for a range of sophisticated applications for metering and monitoring. In addition, trip units can be interchanged in the field to allow for maximum flexibility. The compact size and small footprint of the P-frame circuit breaker permits high density installations in I-Line panelboards and switchboards. These circuit breakers are available in 100% rated construction for all unit-mount circuit breakers and up to 800A in I-Line circuit breakers to meet a broad range of commercial and industrial application needs. The P-frame circuit breakers with K interrupting rating are recommended for applications having high inrush and/or non-linear loads such as large motors, transformers, motors with soft starts, etc. Most field-installable accessories are common to all frame sizes for easier stocking and installation. Selection of four interchangeable Micrologic trip units available, with Powerlogic power metering and monitoring capabilities available in advanced trip units. This PowerPact P, circuit breaker has a rated currrent of 250A and a rated operational current of 600VAC with a breaking capacity of 18 kA@600VAC. This I-Lineed breaker is a 3-pole and has a continuous current rating of 80 %. This breaker has an electronic trip unit technology and a Micrologic 5.0 A trip unit. Dimensions for this product are 12.86 in (H), 8.05 in (W), 8.27 in (D). This product comes with an 18 month warranty.
QTY
  • Product Description
  • Specifications
Providing unparalleled performance and control, the P-frame circuit breakers features the exclusive Micrologic electronic trip units, which allow for a range of sophisticated applications for metering and monitoring. In addition, trip units can be interchanged in the field to allow for maximum flexibility. The compact size and small footprint of the P-frame circuit breaker permits high density installations in I-Line panelboards and switchboards. These circuit breakers are available in 100% rated construction for all unit-mount circuit breakers and up to 800A in I-Line circuit breakers to meet a broad range of commercial and industrial application needs. The P-frame circuit breakers with K interrupting rating are recommended for applications having high inrush and/or non-linear loads such as large motors, transformers, motors with soft starts, etc. Most field-installable accessories are common to all frame sizes for easier stocking and installation. Selection of four interchangeable Micrologic trip units available, with Powerlogic power metering and monitoring capabilities available in advanced trip units. This PowerPact P, circuit breaker has a rated currrent of 250A and a rated operational current of 600VAC with a breaking capacity of 18 kA@600VAC. This I-Lineed breaker is a 3-pole and has a continuous current rating of 80 %. This breaker has an electronic trip unit technology and a Micrologic 5.0 A trip unit. Dimensions for this product are 12.86 in (H), 8.05 in (W), 8.27 in (D). This product comes with an 18 month warranty.
  • Specifications
    • Product Or Component Type : circuit breaker
    • Product Name : PowerPact P
    • Range : PowerPact
    • Device Application : distribution
  • Contractual warranty
    • Warranty : 18 months
  • Complementary
    • Mounting Mode : I-Line bracket)
    • Network Frequency : 50/60 Hz
    • Terminal Identifier : AL800M23K
    • [Ics] Rated Service Breaking Capacity : 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • Trip Unit Technology : electronic, ammeter, Micrologic 5.0 A, LSI
    • Trip Unit Name : Micrologic 5.0 A
    • Height : 12.86 in
    • [Ue] Rated Operational Voltage : 600 V AC 50/60 Hz UL 489
    • Tightening Torque : 50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil) || 1.0-1.3 N.m
    • Mounting Support : bracket
    • Breaking Capacity Code : G
    • Local Signalling : 1 trip indicator green)
    • Number Of Slots : 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
    • Electrical Connection : I-Line connection line || lugs load
    • Mounting Height : 9 in
    • Net Weight : 32 lb(US)
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV IEC 60947-2
    • Control Type : toggle
    • Wire Stripping Length : 25 mm
    • Line Rated Current : 250-250 A
    • Long Time Pick-Up Adjustment Range : 0.4...1 x Ir
    • Continuous Current Rating : 80 %
    • Breaking Capacity : AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
    • [Ui] Rated Insulation Voltage : 750 V IEC 60947-2
    • Poles Description : 3P
    • Quantity Per Set : 1
    • Awg Gauge : 3 x AWG 3/0...3 x 500 kcmil aluminium/copper
    • Width : 8.27 in
    • Depth : 8.05 in
    • Phase Connection : ABC
  • Offer Sustainability
    • Rohs Exemption Information : Yes
    • Mercury Free : Yes
    • Environmental Disclosure : ENVPEP1407012EN
    • Sustainable Offer Status : Green Premium product
    • Pvc Free : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • California Proposition 65 : WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
    • China Rohs Regulation : Product out of China RoHS scope. Substance declaration for your information.
    • Circularity Profile : ENVEOLI1407012EN
    • Eu Rohs Directive : Compliant
  • Environment
    • Ambient Air Temperature For Operation : -2-70 °C
    • Standards : UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
    • Product Certifications : UL || CSA || NOM
    • Ip Degree Of Protection : front cover IP40
    • Pollution Degree : 3 IEC 60947-1
    • Ambient Air Temperature For Storage : -50-85 °C
    • Quality Labels : CE
    • Operating Altitude : < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating