  • Depth: 110 mm
  • Warranty Length: 18 mth
PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 250A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has terminal nuts on the line side and lugs on the load side. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
QTY
  • Product Description
  • Features
  • Specifications
PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 250A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has terminal nuts on the line side and lugs on the load side. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
  • Features
    • Available in 3 or 4 pole design
    • Protection from overloads and short circuits
    • Common accessories across the range
    • Used as main panel disconnect for control panel
    • UL 489 Listed, CSA, NEMA, NMX, VDE, BS, CCC, IEC certified, and CE marked
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Communications & Management Attributes
    • Communication Interface : Modbus, Ethernet
  • Physical Attributes
    • Color : Black
    • Wire Stripping Length : 31 mm
  • Conformance Attributes
    • Product Certifications : UL, CSA, NOM
    • Standards : UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2
  • Complementary Attributes
    • Line Rated Current : 250-250 A
    • Long Time Pick Up Adjustment Range : 0.25...1 x In
  • Important Information Attributes
    • Persona Type Ids : LC, OM, OM8, PB
    • Persona Type Names : Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • AWG Gauge : AWG 2...600 kcmil copper, AWG 2...500 kcmil aluminium
    • Electrical Connection : terminal nut, line, lugs, load
    • Local Signalling : ready 1 LED green), alarm 1 LED 90 % Ir orange), alarm LED 105 % Ir red), switched off (OFF) 1 trip indicator green)
    • Number Of Slots : 2 auxiliary switch OF plug-in), 1 alarm switch SD plug-in), 1 overcurrent trip switch SDE plug-in), 1 voltage release MN or MX plug-in)
    • Tightening Torque : 50-50 N.m 35-300 mm² (AWG 2...600 kcmil), 50-50 N.m 35-240 mm² (AWG 2...500 kcmil)
    • Ics Rated Service Breaking Capacity2 : 65 kA 220/240 V AC 50/60 Hz IEC 60947-2, 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 18 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2
    • Carbon Footprint Of The Distribution Phase A4 : 1.966271580566898, 2 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 10 kg CO2 eq., 10.302971150240523
    • Carbon Footprint Of The Installation Phase A5 : 1.8967904693791804, 2 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 44 kg CO2 eq., 43.82880551360121
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 1 102 kg CO2 eq., 1102.0746377830335
    • Ics Rated Service Breaking Capacity5 : 65 kA 220/240 V AC 50/60 Hz IEC 60947-2, 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2, 18 kA 500/525 V AC 50/60 Hz IEC 60947-2, 20 kA 250 V DC IEC 60947-2, 20 kA 500 V DC IEC 60947-2
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : Yes
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : Outside of Europe
    • EOLI Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2206029_V2
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • China ROHS In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Circuit Breaker Application : HACR rated
    • Continuous Current Rating : 80 %
    • Control Type : toggle
    • Device Application : distribution
    • Device Short Name : L-Frame
    • Long Time Pick Up Adjustment Range : 0.25...1 x In
    • Mounting Mode : unit mount lug)
    • Mounting Support : lug
    • Network Frequency : 50/60 Hz
    • Package Weight Lbs : 6.804 kg
    • Poles Description : 3P
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Or Component Type : circuit breaker
    • Protection Technology : current limiter
    • Range : PowerPact
    • Returnability : Yes
    • Suitability For Isolation : yes IEC 60947-2
    • Sustainable Packaging : No
    • Terminal Identifier : AL400L61K3
    • Total Lifecycle Carbon Footprint : 1 160 kg CO2 eq.
    • Trip Unit Name : MicroLogic 3.3
    • Trip Unit Technology : electronic, standard, MicroLogic 3.3, LI
    • Utilisation Category : category A
    • Ue Rated Operational Voltage2 : 600 V AC 50/60 Hz IEC 60947-3
    • Ui Rated Insulation Voltage2 : 750 V IEC 60947-2
    • Uimp Rated Impulse Withstand Voltage2 : 8 kV IEC 60947-2
    • Medium Desc : Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 25kA, lugs, MicroLogic 3.3, 80%
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP2206029EN
    • Database Version : 2024-01
    • Pep Verification Date : 2027-05-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
    • Data Source : extrapolated product
    • Functional Unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icu, and, if applicable, the specific specifications, in the Industrial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Unit : unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model Installation A5 2 : No energy used
    • Energy Model Use B6 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model End Of Life C1 C4 2 : Global, European and French datasets are used.
    • Global Commercial Status : Commercialised
    • Product Name : PowerPact L
    • Ue Rated Operational Voltage5 : 600 V AC 50/60 Hz IEC 60947-3
    • Ui Rated Insulation Voltage5 : 750 V IEC 60947-2
    • Uimp Rated Impulse Withstand Voltage5 : 8 kV IEC 60947-2
  • Environment Attributes Main
    • Take Back : No, Nej
    • China ROHS Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • EU ROHS Directive : Compliant , Compliant
    • Operating Altitude : < 6561.68 ft (2000 m) without derating, < 6561.68 ft (2000 m) without derating, < 6561.68 ft (2000 m) without derating, < 6561.68 ft (2000 m) without derating, 5000 m with derating
    • ROHS Exemption Information : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 1160.0694764968212
    • Ambient Air Temperature For Operation : -25-70 °C
    • Ambient Air Temperature For Storage : -50-85 °C
    • Circularity Profile : ENVEOLI2206029_V2
    • Environmental Disclosure : ENVPEP2206029EN
    • IP Degree Of Protection : front cover IP40
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Pep Code : ENVPEP2206029EN
    • Pep Verification Date : 2027-05-20
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : circuit breaker
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 110 mm