Circuit breaker, PowerPacT Q, I-Line, thermal magnetic, 225A, 3 pole, 65 kA, 240 VAC, phase ABC, padlock handle

Circuit breaker, PowerPacT Q,

SQDQGA32225YP QGA32225YP 785901442790
4637.14 / EACH
http://schema.org/OutOfStock
  • Country of Origin: Mexico
  • Weight: 3050 g
PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This breaker is 3 pole 225A rated and has 65kA interrupting rating. This unit has I-Line terminations on the line side and mechanical lugs on the load side. It has ABC phasing and has on or off padlock attachment.
QTY
  • Product Description
  • Features
  • Specifications
PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This breaker is 3 pole 225A rated and has 65kA interrupting rating. This unit has I-Line terminations on the line side and mechanical lugs on the load side. It has ABC phasing and has on or off padlock attachment.
  • Features
    • Flexible and simple offer, with proven performance.
    • Available in 2-3 pole design from 75-250A at up to 240 VAC
    • A wide range of field-installable accessories allows customers to reduce inventory without sacrificing flexibility.
    • Easy to install, extremely versatile, a wide variety of terminal options
    • Available in Unit mount (lug-lug, rear, bus bar), I-line or Drawout constructions.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Important Information Attributes
    • Number Of Poles : 3P, 3-pole
    • Product Or Component Type : circuit breaker, Molded case circuit breaker(MCCB)
    • Carbon Footprint Of The Distribution Phase A4 : 0.8814121576615285, 0.9 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 5 kg CO2 eq., 5.14778114700768
    • Carbon Footprint Of The Installation Phase A5 : 0.5891896770204254, 0.6 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 21 kg CO2 eq., 20.90301678197671
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 45 kg CO2 eq., 45.350942261826184
    • Local Data Status : Publishable
    • Local Publishable Date : 2026-09-05
    • Return Indicator : Y
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Weee Scope : In
    • Weee Product Category : 4
    • Scope Perimeter : Outside of Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Conformity Date : 1909
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Product Kit Identifier : N
    • Circuit Breaker Application : HACR rated
    • Control Type : toggle
    • Device Application : distribution
    • Energy Efficiency Optimized : False
    • Network Frequency : 60 Hz
    • Phase Connection : ABC
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : PowerPact Q
    • Quantity Per Set : 1
    • Range : PowerPact
    • Returnability : Yes
    • Software Version : v6.2.5-6
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 73 kg CO2 eq.
    • Database Version : 2024-01
    • Data Source : extrapolated product
    • Nbr. Of Units In Pkg. : 1
    • Customs Code : 8536200020
    • Halogen Free Status : Halogen free product
    • Warranty In Months : 18
    • Functional Unit Description : Protect the installation from overloads and short circuits in a circuit with rated voltage Ue, rated current In, with Np poles, a rated breaking capacity Icn, and the tripping curve Cd if applicable, and, if applicable, the specific specifications, in the Household/Commercial application area, according to the appropriate use scenario, and during the reference service life of the product of 20 years.
    • Functional Unit Quantity : 1
    • Functional Unit Unit : unit
    • Reference Lifetime In Y : 20
    • Recyclability Potential In % : 56
    • Pep End Of Validity Date Calculated : 2030-07-01
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -13-158 °F, -25-70 °C, -13-158 °F, -25-70 °C
    • Ambient Air Temperature For Storage : -58-185 °F, -50-85 °C, -58-185 °F, -50-85 °C
    • Take Back : No
    • Halogene Performance : Halogen free product
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 72.87234202549253
    • Environmental Disclosure : ENVPEP2311048_V2
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free product
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP2311048_V2
    • Pep Verification Date : 2025-07-01
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Type Of Verification For The Pep : Independent external review
  • Specifications
    • Country of Origin : Mexico
    • Weight : 3050 g
  • General Attributes
    • Product Or Component Type : circuit breaker, Molded case circuit breaker(MCCB)