Circuit breaker, ComPacT NSX250F, 36kA/415VAC, 3 poles, TMD trip unit 250A

CIRCUIT BREAKER, COMPACT NSX25

SQDC25F3TM250 C25F3TM250 3606481997142
4202.95 / EA
http://schema.org/OutOfStock
  • Depth: 86 mm
This ComPacT NSX250F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 250A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX250F is part of Schneider Electric EcoStruxure Power architecture.
QTY
  • Product Description
  • Features
  • Specifications
This ComPacT NSX250F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 250A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX250F is part of Schneider Electric EcoStruxure Power architecture.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Line Rated Current : 250 A 40 °C
    • Long Time Delay Adjustment Type : fixed
    • Rated Current : 250 A
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SC, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, Electrician, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electrical Durability : 20000 cycles 440 V In/2, 10000 cycles 440 V In, 10000 cycles 690 V In/2, 5000 cycles 690 V In
    • Mounting Position : horizontal and vertical, flat on the back
    • Protection Type : L : for overload protection (thermal), I : for short-circuit protection (magnetic)
    • [Ics] Rated Service Breaking Capacity : 85 kA 220/240 V AC 50/60 Hz IEC 60947-2, 36 kA 380/415 V AC 50/60 Hz IEC 60947-2, 35 kA 440 V AC 50/60 Hz IEC 60947-2, 30 kA 500 V AC 50/60 Hz IEC 60947-2, 22 kA 525 V AC 50/60 Hz IEC 60947-2, 8 kA 660/690 V AC 50/60 Hz IEC 60947-2
    • [Tr] Long-time Delay Adjustment Range : 120-400 s 1.5 x In, 15-15 s 6 x Ir
    • Carbon Footprint Of The Distribution Phase [A4] : 0.59324, 0.6 kg CO2 eq.
    • Carbon Footprint Of The End-of-life Phase [C1 To C4] : 3.4793, 3 kg CO2 eq.
    • Carbon Footprint Of The Installation Phase [A5] : 0.2 kg CO2 eq., 0.17371
    • Carbon Footprint Of The Manufacturing Phase [A1 To A3] : 11 kg CO2 eq., 11.368
    • Carbon Footprint Of The Use Phase [B2, B3, B4, B6] : 303 kg CO2 eq., 302.94
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-10
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 1
    • Device Type : LV equipment - Low voltage circuit breaker
    • Serviceability : No
    • Traceability : Yes
    • Field Service Division : PPIBS
    • Average Life Duration : 15 year(s)
    • Manufacturing Carbon Footprint : 11.368
    • Use Carbon Footprint : 302.94
    • End Of Life Carbon Footprint : 3.4793
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI2304017EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 2117
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 7
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : NSX250
    • Connection Pitch : 35 mm
    • Control Type : toggle
    • Device Application : distribution
    • Device Short Name : NSX250F
    • Downside Connection : front
    • Electrical Shock Protection Class : class II front face
    • Energy Efficiency Optimized : False
    • Mechanical Durability : 20000 cycles
    • Mounting Mode : fixed
    • Mounting Support : backplate
    • Network Frequency : 50/60 Hz
    • Network Type : AC
    • Number Of Poles : 3P
    • Number Of Slots : 5
    • Overvoltage Category : III
    • Poles Description : 3P
    • Power Dissipation Per Pole : 18.75 W
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Name : ComPacT NSX
    • Product Or Component Type : circuit breaker
    • Protected Poles Description : 3D
    • Range : ComPacT
    • Range Of Product : ComPacT NSX100...250
    • Returnability : No
    • Software Version : v5.9.4
    • Suitability For Isolation : yes EN/IEC 60947-2
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 319 kg CO2 eq.
    • Trip Unit Name : TM-D
    • Trip Unit Protection Functions : LI
    • Trip Unit Rating : 250-250 A 40 °C
    • Trip Unit Technology : thermal-magnetic
    • Upside Connection : front
    • Utilisation Category : category A
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • China Green Design Product : Yes
    • Rated Current 1 : 250 A
    • Circuit Breaker Rating Code 1 Breaking Capacity : 36 kA
    • Pep Code : ENVPEP2304017EN
    • Database Version : 2022-01
    • Pep Verification Date : 2023-06-30
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
    • Data Source : referent product
    • Functional-unit Description : Protect during 20 years the installation against overloads and short-circuits in circuit with assigned voltage up to 690V AC and rated current up to 250A. This protection is ensured in accordance with the following parameters:& 10- Number of poles = 3P& 10- Rated breaking capacity = F 36kA 415V AC& 10- Tripping curve = Type C [LI = long time, instantaneous]& 10- IP degree of protection = IP40 conforming to IEC 60529& 10- IK degree of protection = IK07 conforming to IEC 62262
    • Functional-unit Quantity : 1
    • Functional-unit Unit : unité (unit)
    • Reference Lifetime, In Y : 20
    • Energy Consumption On Product Lifetime, In Kwh : 739.125
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; PL
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; UE-27
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; UE-27
    • Recyclability Potential, In % : 54
    • Height Nominal : 161 mm
    • Width Nominal : 105 mm
    • Certificate Agency : EN/IEC 60947-2
    • [Ue] Rated Operational Voltage : 690 V AC 50/60 Hz
    • [Ui] Rated Insulation Voltage : 800 V AC 50/60 Hz
    • [Uimp] Rated Impulse Withstand Voltage : 8 kV
    • Instantaneous Pick-up Adjustment Range : 5...10 x In
    • Long Time Pick-up Adjustment Range : 0.7...1 x In
    • Earth-leakage Protection : without
    • Instantaneous Pick-up Adjustment Type Ii : adjustable
    • Long Time Pick-up Adjustment Type Ir : adjustable
    • Halogen-free Status : Product contains halogen above thresholds
    • Nbr. Of Units In Pkg. : 1
    • Package Weight(Lbs) : 1.962 kg
    • Take-back : No
    • Warranty (In Months) : 18
    • Acidification (Ap) (Mole Of H+ Equiv) Operational Energy Use [B6] : 1.7287
    • Climate Change - Biogenics ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D] : -0.272
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Manufacturing [A1-a3] : 11.203
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 302.54
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) End Of Life [C1-c4] : 3.4088
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D] : -32.594
    • Climate Change - Total ( Kg Co2 Eq.) Manufacturing [A1-a3] : 11.368
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 302.94
    • Climate Change - Total ( Kg Co2 Eq.) End Of Life [C1-c4] : 3.4793
    • Climate Change - Total ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D] : -32.866
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 196.12
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Distribution [A4] : 7.2034
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Installation [A5] : 1.8108
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 7718.1
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4] : 161.63
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Benefits/Loads Beyond System Boundaries [D] : -727.56
    • Ecotoxicity (Fresh Water) (Ctue) Total Life Cycle : 4315.3937
    • Ecotoxicity (Fresh Water) (Ctue) Manufacturing [A1-a3] : 792.67
    • Ecotoxicity (Fresh Water) (Ctue) Distribution [A4] : 2.4329
    • Ecotoxicity (Fresh Water) (Ctue) Installation [A5] : 1.1808
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 3262.5
    • Ecotoxicity (Fresh Water) (Ctue) End Of Life [C1-c4] : 256.61
    • Ecotoxicity (Fresh Water) (Ctue) Benefits/Loads Beyond System Boundaries [D] : -609.03
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 151.58
    • Hazardous Waste Disposed Of (Kg) End Of Life [C1-c4] : 2.2254
    • Hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -864.29
    • Impacts Related To Land Use/Soil Quality (-) Operational Energy Use [B6] : 6.0277
    • Impacts Related To Land Use/Soil Quality (-) End Of Life [C1-c4] : 6.4806
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Manufacturing [A1-a3] : 111.02
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 450.43
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Benefits/Loads Beyond System Boundaries [D] : -293.59
    • Materials For Recycling (Kg) End Of Life [C1-c4] : 1.0684
    • Net Use Of Fresh Water (M3) Manufacturing [A1-a3] : 0.1411
    • Net Use Of Fresh Water (M3) Benefits/Loads Beyond System Boundaries [D] : -0.4807
    • Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 8.1308
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 43.587
    • Non-hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -25.519
    • Terrestrial Eutrophication (Mole Of N Equiv) Operational Energy Use [B6] : 2.9509
    • Terrestrial Eutrophication (Mole Of N Equiv) Benefits/Loads Beyond System Boundaries [D] : -0.2342
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 17.03
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 17.03
    • Total Use Of Primary Energy During The Life Cycle (Mj) Total Life Cycle : 9575.3735
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 202.71
    • Total Use Of Primary Energy During The Life Cycle (Mj) Distribution [A4] : 7.2035
    • Total Use Of Primary Energy During The Life Cycle (Mj) Installation [A5] : 1.94
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 9200.2
    • Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4] : 163.32
    • Total Use Of Primary Energy During The Life Cycle (Mj) Benefits/Loads Beyond System Boundaries [D] : -737.61
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 6.5889
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 1482.1
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) End Of Life [C1-c4] : 1.6929
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Benefits/Loads Beyond System Boundaries [D] : -10.052
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 17.03
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 17.03
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 8067.8342
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 179.09
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Distribution [A4] : 7.2034
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Installation [A5] : 1.8108
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 7718.1
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 161.63
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -727.56
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 5.9098
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1482.1
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 1.6929
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -9.444
    • Water Use (M3 Eq) Manufacturing [A1-a3] : 6.06
    • Water Use (M3 Eq) Operational Energy Use [B6] : 10.719
    • Water Use (M3 Eq) End Of Life [C1-c4] : 2.6818
    • Water Use (M3 Eq) Benefits/Loads Beyond System Boundaries [D] : -20.645
    • Customs Code : 8536200020
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -25-70 °C, -25-70 °C
    • Ambient Air Temperature For Storage : -50-85 °C, -50-85 °C
    • Operating Altitude : 0...6561.68 ft (0...2000 m) without derating, 2000 m...5000 m with derating
    • Take Back : No
    • Halogene Performance : Product contains halogen above thresholds
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Carbon Footprint : 318.55425
    • Circularity Profile : ENVEOLI2304017EN
    • Environmental Disclosure : ENVPEP2304017EN
    • Eu Rohs Directive : Compliant
    • Halogen Content Performance : Product contains halogen above thresholds
    • Ip Degree Of Protection : IP40 conforming to IEC 60529
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 0-95 %
    • Pep Code : ENVPEP2304017EN
    • Pep Verification Date : 2023-06-30
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent external review
  • General Attributes
    • Product Or Component Type : circuit breaker
    • Range Of Product : ComPacT NSX100...250
  • ETIM
    • ETIM 8 : EC000228
    • ETIM 9 : EC000228
  • Specifications
    • Country of Origin : Brazil, Spain, France, Indonesia, Philippines, Poland, United States
    • Depth : 86 mm