Capacitor contactor, Tesys Deca, 63kVAR at 400/415V 50Hz, 220V AC 50/60Hz coil, screw clamp terminals

CAPACITOR CONTACTOR, TESYS DEC

SQDLC1DWK12M7 LC1DWK12M7 3389110060539
1781.93 / EA
http://schema.org/OutOfStock
  • Depth: 154 mm
  • Warranty Length: 18 mth
TeSys Deca contactor, 3 poles (3NO), for switching 3-phase capacitor banks up to 63kVAR@400V 50Hz (104kVAR@690V). It provides a 220V 50/60Hz AC coil, 1NO+2NC instantaneous auxiliary contacts, with front mounted early make poles and pre-wired damping resistors for current limitation. For operating rates until 240 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA) and compliant with shunt capacitors standard IEC 60831.
QTY
  • Product Description
  • Features
  • Specifications
TeSys Deca contactor, 3 poles (3NO), for switching 3-phase capacitor banks up to 63kVAR@400V 50Hz (104kVAR@690V). It provides a 220V 50/60Hz AC coil, 1NO+2NC instantaneous auxiliary contacts, with front mounted early make poles and pre-wired damping resistors for current limitation. For operating rates until 240 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA) and compliant with shunt capacitors standard IEC 60831.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Complementary Attributes
    • Control Circuit Type : AC 50/60 Hz
    • Maximum Operating Rate : 100 cyc/h
    • Uc Control Circuit Voltage : 220 V AC 50/60 Hz
    • Ue Rated Operational Voltage : power circuit 690 V AC 50/60 Hz
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB, SI
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electrical Durability : 300000 cycles 400 V, 200000 cycles 690 V
    • Mounting Support : DIN rail, plate
    • Product Name : TeSys LC1D.K, TeSys Deca
    • Product Or Component Type : capacitor duty contactor
    • Range : TeSys
    • Reactive Power Rating : 35 kvar 230-230 V AC 50 Hz 60 °C, 63 kvar 400-400 V AC 50 Hz 60 °C, 67 kvar 440-440 V AC 50 Hz 60 °C, 104 kvar 690-690 V AC 50 Hz 60 °C, 30 kvar 230-230 V AC 60 Hz 60 °C, 60 kvar 460-460 V AC 60 Hz 60 °C, 80 kvar 575-575 V AC 60 Hz 60 °C
    • Tightening Torque : power circuit 9 N.m connector, control circuit 1.7 N.m screw clamp terminals
    • Connections Terminals : control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 4-25 mm² - cable stiffness: solid, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable endcontrol circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 4-50 mm² - cable stiffness: solid
    • Carbon Footprint Of The Distribution Phase A4 : 0.52233, 0.5 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 5 kg CO2 eq., 4.7072
    • Carbon Footprint Of The Installation Phase A5 : 0.29663, 0.3 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 11 kg CO2 eq., 10.946
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 81 kg CO2 eq., 80.77
    • Certificate Agency : IECEE CB Scheme, UL, CSA, UKCA
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Return Indicator : N
    • Stocking Flag : Y
    • Stock Policy : 2
    • Device Type : LV equipment - LV contactor
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Manufacturing Carbon Footprint : 10.946
    • Use Carbon Footprint : 80.77
    • End Of Life Carbon Footprint : 4.7072
    • Weee Scope : In
    • Weee Product Category : 5
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant
    • Rohs Eur Conformity Date : 1924
    • Rohs Eur Full Compliance Status : Compliant
    • China Rohs In Scope : No
    • China Rohs Label : 1
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Tier Id : 1
    • Tier : 1
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Compatibility Code : LC1D
    • Contactor Application : power factor correction
    • Device Application : control
    • Device Short Name : LC1DWK
    • Number Of Poles : 3P
    • Pole Contact Composition : 3 NO
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Range Of Product : TeSys Deca
    • Returnability : No
    • Software Version : v5.9.4
    • Sustainable Packaging : Yes
    • Total Lifecycle Carbon Footprint : 97 kg CO2 eq.
    • Utilisation Category : AC-6b
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Warranty In Months : 18
    • Control Circuit Voltage 18 Control Circuit Voltage : 220 V
    • Control Circuit Type 1 Network Frequency : 50/60 Hz
    • Pep Code : ENVPEP1112074EN
    • Database Version : 2022-01
    • Pep Verification Date : 2025-11-10
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
    • Data Source : referent product
    • Functional-unit Description : Switch on and off during 20 years electrical power supply of a downstream installation with an electrical and/or mechanical control.The functional unit is characterized by a type Capacitor duty contactor, a control circuit voltage 220V, a power circuit voltage 690V and a rated operational current 80A.
    • Functional-unit Quantity : 1
    • Functional-unit Unit : Unit
    • Reference Lifetime, In Y : 20
    • Energy Model - Manufacturing [A1-a3] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Installation [A5] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - Use [B6] : Electricity Mix; Production mix; Low voltage; FR
    • Energy Model - End Of Life [C1-c4] : Electricity Mix; Production mix; Low voltage; FR
    • Recyclability Potential, In % : 67
    • Height Nominal : 180 mm
    • Width Nominal : 85 mm
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Manufacturing [A1-a3] : 10.636
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Operational Energy Use [B6] : 80.562
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) End Of Life [C1-c4] : 4.6736
    • Climate Change - Fossil Fuels ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D] : -121.43
    • Climate Change - Total ( Kg Co2 Eq.) Manufacturing [A1-a3] : 10.946
    • Climate Change - Total ( Kg Co2 Eq.) Operational Energy Use [B6] : 80.77
    • Climate Change - Total ( Kg Co2 Eq.) End Of Life [C1-c4] : 4.7072
    • Climate Change - Total ( Kg Co2 Eq.) Benefits/Loads Beyond System Boundaries [D] : -121.78
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Total Life Cycle : 15949.24
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Manufacturing [A1-a3] : 220.55
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Distribution [A4] : 6.3424
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Installation [A5] : 3.0876
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Operational Energy Use [B6] : 15510
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) End Of Life [C1-c4] : 209.26
    • Depletion Of Abiotic Resources - Fossil Fuels (Mj) Benefits/Loads Beyond System Boundaries [D] : -2754.1
    • Ecotoxicity (Fresh Water) (Ctue) Total Life Cycle : 4481.1264
    • Ecotoxicity (Fresh Water) (Ctue) Manufacturing [A1-a3] : 3782.4
    • Ecotoxicity (Fresh Water) (Ctue) Distribution [A4] : 2.1421
    • Ecotoxicity (Fresh Water) (Ctue) Installation [A5] : 2.0243
    • Ecotoxicity (Fresh Water) (Ctue) Operational Energy Use [B6] : 570.43
    • Ecotoxicity (Fresh Water) (Ctue) End Of Life [C1-c4] : 124.13
    • Ecotoxicity (Fresh Water) (Ctue) Benefits/Loads Beyond System Boundaries [D] : -2110.3
    • Hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 129.11
    • Hazardous Waste Disposed Of (Kg) End Of Life [C1-c4] : 1.7346
    • Hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -2993.5
    • Impacts Related To Land Use/Soil Quality (-) Operational Energy Use [B6] : 2.5748
    • Impacts Related To Land Use/Soil Quality (-) End Of Life [C1-c4] : 3.0988
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Manufacturing [A1-a3] : 2456.2
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Operational Energy Use [B6] : 2093.6
    • Ionizing Radiation, Human Health (Kbq Of U235 Equiv.) Benefits/Loads Beyond System Boundaries [D] : -136.26
    • Materials For Recycling (Kg) Total Life Cycle : 1.2976
    • Materials For Recycling (Kg) Installation [A5] : 0.163
    • Materials For Recycling (Kg) End Of Life [C1-c4] : 1.1346
    • Net Use Of Fresh Water (M3) Benefits/Loads Beyond System Boundaries [D] : -1.2384
    • Non-hazardous Waste Disposed Of (Kg) Manufacturing [A1-a3] : 7.2364
    • Non-hazardous Waste Disposed Of (Kg) Operational Energy Use [B6] : 7.7665
    • Non-hazardous Waste Disposed Of (Kg) Benefits/Loads Beyond System Boundaries [D] : -100.49
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Total Life Cycle : 15.686
    • Total Use Of Non-renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 15.686
    • Total Use Of Primary Energy During The Life Cycle (Mj) Manufacturing [A1-a3] : 225.58
    • Total Use Of Primary Energy During The Life Cycle (Mj) Distribution [A4] : 6.3424
    • Total Use Of Primary Energy During The Life Cycle (Mj) Installation [A5] : 3.3091
    • Total Use Of Primary Energy During The Life Cycle (Mj) Operational Energy Use [B6] : 16944
    • Total Use Of Primary Energy During The Life Cycle (Mj) End Of Life [C1-c4] : 210.08
    • Total Use Of Primary Energy During The Life Cycle (Mj) Benefits/Loads Beyond System Boundaries [D] : -2778.5
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Manufacturing [A1-a3] : 5.0316
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Operational Energy Use [B6] : 1433.9
    • Total Use Of Renewable Primary Energy Resources (Primary Energy And Primary Energy Resources Used As Raw Materials) (Mj) Benefits/Loads Beyond System Boundaries [D] : -24.48
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 15.686
    • Use Of Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 15.686
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 15933.56
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 204.87
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Distribution [A4] : 6.3424
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Installation [A5] : 3.0876
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 15510
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) End Of Life [C1-c4] : 209.26
    • Use Of Non-renewable Primary Energy, Excluding Non-renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -2754.1
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Total Life Cycle : 2.6296
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 2.6296
    • Use Of Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -2.934
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Manufacturing [A1-a3] : 2.4021
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Operational Energy Use [B6] : 1433.9
    • Use Of Renewable Primary Energy, Excluding Renewable Primary Energy Resources Used As Raw Materials (Mj) Benefits/Loads Beyond System Boundaries [D] : -21.546
    • Water Use (M3 Eq) Manufacturing [A1-a3] : 4.0178
    • Water Use (M3 Eq) Distribution [A4] : 0.0265
    • Water Use (M3 Eq) Operational Energy Use [B6] : 5.85
    • Water Use (M3 Eq) End Of Life [C1-c4] : 2.0745
    • Water Use (M3 Eq) Benefits/Loads Beyond System Boundaries [D] : -53.184
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Pro-active China RoHS declaration (out of China RoHS legal scope)
    • Ambient Air Temperature For Operation : -5-60 °C, -5-60 °C
    • Ambient Air Temperature For Storage : -60-80 °C, -60-80 °C
    • Take Back : No
    • Reach Free Shvc : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 97.24216
    • Environmental Disclosure : ENVPEP1112074EN
    • Eu Rohs Directive : Compliant
    • Ip Degree Of Protection : IP20 front face IEC 60529
    • Operating Altitude : 0...9842.52 ft (0...3000 m)
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Free Of Svhc : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1112074EN
    • Pep Verification Date : 2025-11-10
    • Pcr Version : PEP-PCR-ed4-2021 09 06
    • Psr Version : PSR-0005-ed2-2016 03 29
    • Type Of Verification For The Pep : Independent internal review
  • General Attributes
    • Product Or Component Type : capacitor duty contactor
    • Range Of Product : TeSys Deca
  • ETIM
    • ETIM 8 : EC001079
    • ETIM 9 : EC001079
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Brazil, China, Czechia, France
    • Depth : 154 mm