Busway, I-Line, plug in, tap box, 400A, 600VAC, aluminum, 600A, 600 VAC, copper, 3 phase, 4 wire, integral ground bus

SQD PBTB506G BUSWAY PLUG-IN TA

SQDPBTB506G PBTB506G 785901787198
10930.34 / EACH
http://schema.org/OutOfStock
  • Depth: 197 mm
  • Material: Aluminum
  • Warranty Length: 18 mth
I-Line™ Busway offers a complete line of compatible, sandwich-type feeder and plug-in busway lengths, fittings, and plug-in units. I-Line plug-in busway has options up to 1600A for circuit breaker plug-ins and 1200A for fusible plug-ins. Circuit breaker and fusible plug in units are available in 3 phase, 3 wire or 3 phase, 4 wire configurations, with Aluminum or Copper conductors, for system voltages up to 600 volts. This busway system is rated to allow 100% of the current to flow continuously. This I-Line plug-in tap box is for 400A to 600A, 600VAC, 3 phase, 4 wire with integral ground bus systems. I-Line busway is UL listed and CSA certified. I-Line Busway plug-in units are UL listed and CSA certified.
QTY
  • Product Description
  • Features
  • Specifications
I-Line™ Busway offers a complete line of compatible, sandwich-type feeder and plug-in busway lengths, fittings, and plug-in units. I-Line plug-in busway has options up to 1600A for circuit breaker plug-ins and 1200A for fusible plug-ins. Circuit breaker and fusible plug in units are available in 3 phase, 3 wire or 3 phase, 4 wire configurations, with Aluminum or Copper conductors, for system voltages up to 600 volts. This busway system is rated to allow 100% of the current to flow continuously. This I-Line plug-in tap box is for 400A to 600A, 600VAC, 3 phase, 4 wire with integral ground bus systems. I-Line busway is UL listed and CSA certified. I-Line Busway plug-in units are UL listed and CSA certified.
  • Features
    • Compact and totally enclosed design makes it lightweight and easy to handle
    • Easy and quick installation, get up to 75% savings in installation time
    • Utilizes sandwich-type construction to provide superior voltage drop characteristics, even at low power factors
    • Made of tough, durable and uniform polyester powder coat paint finish
    • Plated to ensure low surface-to-surface contact resistance
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Conformance Attributes
    • Product Certifications : UL listed file E22182, CSA C22.2 No 27
    • Standards : UL 857
  • Complementary Attributes
    • Line Rated Current : 600-600 A, 400-400 A
  • Important Information Attributes
    • Persona Type Ids : LC, OM8, PB, SI
    • Persona Type Names : Contractor, OEM - Control Panelbuilder, Panel Builder, System Integrator
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • AWG Gauge : AWG 2...600 kcmil 2 phase and neutral, AWG 1/0 2 ground
    • Carbon Footprint Of The Distribution Phase A4 : 12.386334578916196, 12 kg CO2 eq.
    • Carbon Footprint Of The End Of Life Phase C1 To C4 : 13 kg CO2 eq., 12.596585467001546
    • Carbon Footprint Of The Installation Phase A5 : 0.8277868424172027, 0.8 kg CO2 eq.
    • Carbon Footprint Of The Manufacturing Phase A1 To A3 : 25 kg CO2 eq., 24.953828689483696
    • Carbon Footprint Of The Use Phase B2 B3 B4 B6 : 169 kg CO2 eq., 168.96567536299636
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-11-13
    • Device Type : Busway & cable - LV busway
    • Serviceability : No
    • Traceability : No
    • Field Service Division : PPIBS
    • Average Life Duration : 20 year(s)
    • Legacy WEEE Scope : In
    • Scope Perimeter : At least in Europe
    • EOLI Availability Display : No need of specific recycling operations
    • Reach Full Compliance Status : Free of Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : NOT_CONTAINING_SVHC
    • Reach Compliance Directive : Free of Substances of Very High Concern above the threshold
    • ROHS EUR In Scope : Yes
    • ROHS EUR Status : Compliant
    • ROHS EUR Full Compliance Status : Compliant
    • ROHS EUR Full Compliance Status Id : COMPLIANT
    • Green Premium Status For Reporting : Green Premium product
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : No
    • Product Contributes To Saved And Avoided Emissions : No
    • Return Indicator : Y
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Energy Efficiency Optimized : False
    • Material : aluminium
    • Mounting Mode : plug-in
    • Package Weight Lbs : 28.123 kg
    • Phase : 3 phase
    • Product Availability : Non-Stock - Not normally stocked in distribution facility
    • Product Or Component Type : tap box
    • Range Of Product : I-Line
    • Returnability : Yes
    • Sustainable Packaging : No
    • Total Lifecycle Carbon Footprint : 220 kg CO2 eq.
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Wiring Configuration : 4-wire (integral ground bus)
    • Medium Desc : Busway, I-Line, plug in, tap box, 400A, 600VAC, aluminum, 600A, 600 VAC, copper, 3 phase, 4 wire, integral ground bus
    • Stocking Flag : Y
    • Product Kit Identifier : N
    • Pep Code : ENVPEP1407014EN
    • Database Version : 2024-01
    • Pep Verification Date : 2025-01-30
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
    • Data Source : extrapolated product
    • Functional Unit Description : Other switchgear and controlgear solutions mentioned in the scope (e.g. fuses TC32, all-or-nothing relays TC94, Measuring relays and protection equipment TC95), apply the general rules of PCR and mention in the accompanying report the functional unit, the reference product characteristics, the reference lifetime and the use scenario which are applied consistently with the relevant IEC technical standards.
    • Functional Unit Unit : Unit
    • Energy Model Manufacturing A1 A3 2 : Electricity Mix; Low voltage; 2020; United States, US
    • Energy Model Installation A5 2 : Electricity origin
    • Energy Model Use B6 2 : Electricity origin
    • Energy Model End Of Life C1 C4 2 : Electricity origin
    • Global Commercial Status : Commercialised
  • Environment Attributes Main
    • EU ROHS Directive : Compliant , Compliant
    • ROHS Exemption Information : Yes
    • Take Back : No
    • Reach Free SHVC : Yes
    • Recycled Metal Content At Cr Level : 0 %
    • China ROHS Regulation : X
    • Toxic Heavy Metal Free : Yes
    • Mercury Free : Yes
    • Carbon Footprint : 219.730210940815
    • Environmental Disclosure : ENVPEP1407014EN
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : No
    • Reach Free Of SVHC : Yes
    • Reach Regulation : Free of Substances of Very High Concern above the threshold
    • Pep Code : ENVPEP1407014EN
    • Pep Verification Date : 2025-01-30
    • Pcr Version : PCR-4-ed4-EN-2021 09 06
    • Psr Version : PSR-0005-ed3.1-EN-2023 12 08
  • General Attributes
    • Phase : 3 phase
    • Product Or Component Type : tap box
    • Range Of Product : I-Line
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Depth : 197 mm