SQUARE D

Bus coupler, TeSys island, 24VDC, 3A, Profinet IO

BUS COUPLER, TESYS ISLAND, PRO

SQDTPRBCPFN TPRBCPFN 3606489832711
427.93 / EA
http://schema.org/OutOfStock
  • Depth: 114 mm
  • Warranty Length: 18 mth
TeSys island bus coupler, point of connection between a TeSys island configuration (group of starters) and an automation system over PROFINET IO. It performs all functions for the application (TeSys avatars), selectable and configurable through SoMove or MachineExpert. For diagnostics and maintenance of the TeSys island, a web server (OMT) is embedded. To be supplied externally by 24V DC, it provides two RJ45 ports for PROFINET IO, one RJ45 service port over Ethernet, one micro SD card port, and a port for the internal bus interconnecting the modules of the island. Mounting on DIN rail, together with the other modules of the TeSys island configuration, the bus coupler is the module on the most left position. Multi standards certified (IEC, UL, CSA, CCC, EAC), cybersecurity Achilles Level 2 certified.
QTY
  • Product Description
  • Features
  • Specifications
TeSys island bus coupler, point of connection between a TeSys island configuration (group of starters) and an automation system over PROFINET IO. It performs all functions for the application (TeSys avatars), selectable and configurable through SoMove or MachineExpert. For diagnostics and maintenance of the TeSys island, a web server (OMT) is embedded. To be supplied externally by 24V DC, it provides two RJ45 ports for PROFINET IO, one RJ45 service port over Ethernet, one micro SD card port, and a port for the internal bus interconnecting the modules of the island. Mounting on DIN rail, together with the other modules of the TeSys island configuration, the bus coupler is the module on the most left position. Multi standards certified (IEC, UL, CSA, CCC, EAC), cybersecurity Achilles Level 2 certified.
  • Prop 65
    • WARNING: This product can expose you to chemicals including: Carbon black, which is known to the State of California to cause cancer, and Toluene, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Assets
    • Cad : https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_3D-simplified.stp, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-back.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-back.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-bottom.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-bottom.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-front.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-front.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-isometric.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-isometric.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-left.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-left.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-right.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-right.dxf, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-top.dwg, https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005277_3D-CAD&p_File_name=MCADPD0005277_2D-top.dxf
  • Communications & Management Attributes
    • Communication Service : conformance class A (CC-A), net load class 1, DHCP client, SNTP client
    • Communication Port Protocol : Profinet IO
  • Conformance Attributes
    • Product Certifications : UL, CSA, EAC, Achilles level 2, PNO
    • Standards : EN/IEC 60947-4-1, CSA C22.2 No 61010-2-201, UL 61010-2-201, EN/IEC 61010-2-201
  • Complementary Attributes
    • Integrated Connection Type : 2 RJ45 female Profinet IO, fieldbus port, 1 RJ45 female Ethernet TCP/IP, service port, 1 micro SD card port
    • Rated Current : 3 A maximum
    • Us Rated Supply Voltage : 24 V DC
  • Important Information Attributes
    • Persona Type Ids : EU, LC, OM, OM8, PB
    • Persona Type Names : End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
    • Market Segmentation Id : COMMERCIAL, INDUSTRIAL
    • Market Segmentation : Commercial, Industrial
    • Electromagnetic Compatibility : power supply: surge immunity test (common mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5, electrostatic discharge, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2, radiated RF fields, level 3, 10 V/m, conforming to EN/IEC 61000-4-3, communication: fast transients immunity test, level 3, 1 kV, conforming to EN/IEC 61000-4-4, power supply: fast transients immunity test, level 3, 2 kV, conforming to EN/IEC 61000-4-4, communication: surge immunity test (common mode), level 3, 1 kV, conforming to EN/IEC 61000-4-5
    • Function Available : full integration with SoMove for the control of the island, one single 24V DC power supply for the complete island, two fieldbus ports for communication with an automation controller, one service port with an embedded webserver for maintenance
    • Local Signalling : 1 LED green/yellow PWR power supply status, 1 LED green/red SF system fault, 1 LED green/red BF network status, 1 LED green/red BS internal bus status, 1 LED green/red SD SD card access (SD)
    • Protection Type : external fuse, 3 A fast power supply, reverse polarity protection power supply
    • Vibration Resistance : 1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6, 1 gn 13-200 Hz) IEC 60068-2-6
    • Medium Desc : Bus coupler, TeSys island, 24VDC, 3A, Profinet IO
    • Local Data Status : Publishable
    • Local Publishable Date : 2025-07-09
    • Global Commercial Status : Commercialised
    • Return Indicator : Y
    • Stocking Flag : N
    • Device Type : Relay, Control & Measurement - measuring, monitoring device
    • Serviceability : No
    • Traceability : No
    • Weee Applicability : Finished product
    • Weee Scope : In
    • Legacy Weee Scope : In
    • Scope Perimeter : At least in Europe
    • Eoli Availability Display : Yes
    • End Of Life Doc Ref : ENVEOLI1904009EN
    • Reach Full Compliance Status : Reference contains Substances of Very High Concern above the threshold
    • Reach Full Compliance Status Id : CONTAINS_SVHC
    • Reach Compliance Directive : Reference contains Substances of Very High Concern above the threshold
    • Rohs Eur In Scope : Yes
    • Rohs Eur Status : Compliant By Exemption
    • Rohs Eur Full Compliance Status : Compliant By Exemption
    • China Rohs In Scope : No
    • With Recycled Cardboard : Yes
    • Without Single Use Plastic : Yes
    • Product Contributes To Saved And Avoided Emissions : No
    • Function Option Id : STANDARD
    • Function Option : Standard
    • Product Kit Identifier : N
    • Cybersecurity : Achilles certified
    • Device Short Name : TPRBC
    • Energy Efficiency Optimized : False
    • Fire Resistance : 960 °C UL 94
    • Halogen Free Status : Halogen free plastic parts and cables product
    • Mounting Mode : horizontal and vertical 35 mm symmetrical rail)
    • Power Dissipation In W : 7 W maximum
    • Product Availability : Stock - Normally stocked in distribution facility
    • Product Name : TeSys island
    • Product Or Component Type : bus coupler
    • Protective Treatment : TC
    • Range : TeSys
    • Returnability : Yes
    • Shock Resistance : 15 gn 11 ms) IEC 60068-2-27
    • Supply Voltage Limits : 20.4-28.8 V DC
    • Sustainable Packaging : No
    • Weee Label : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    • Connections Terminals : power supply removable spring terminal block 2 2.5-2.5 mm² AWG 14)rigid or flexible
    • Pep Code : ENVPEP1904009EN
    • Height Nominal : 118 mm
    • Width Nominal : 50 mm
  • Environment Attributes Main
    • China Rohs Regulation : Product out of China RoHS scope , Product out of China RoHS scope. Substance declaration for your information.
    • Ambient Air Temperature For Operation : -10-60 °C, -10-60 °C
    • Ambient Air Temperature For Storage : -25-70 °C, -25-70 °C
    • Product Compatibility : TPRST motor starter, TPRSS SIL motor starter, TPRPM power module, TPRSM SIL interface module, TPRVM voltage interface module, TPRAN analog IO module, TPRDG digital IO module
    • Take Back : Nej
    • Halogene Performance : Halogen free plastic parts & cables product
    • Recycled Metal Content At Cr Level : 0 %
    • Mercury Free : Yes
    • Circularity Profile : ENVEOLI1904009EN
    • Environmental Disclosure : ENVPEP1904009EN
    • Eu Rohs Directive : Compliant By Exemption
    • Halogen Content Performance : Halogen free plastic parts & cables product
    • Ip Degree Of Protection : IP20
    • Operating Altitude : 0...6561.68 ft (0...2000 m) without derating
    • Packaging Made With Recycled Cardboard : Yes
    • Packaging Without Single Use Plastic : Yes
    • Reach Regulation : Reference contains Substances of Very High Concern above the threshold
    • Relative Humidity : 5-95 %
    • Pep Code : ENVPEP1904009EN
  • General Attributes
    • Product Or Component Type : bus coupler
  • ETIM
    • ETIM 8 : EC001604
    • ETIM 9 : EC001604
  • Contractual Warranty Attributes
    • Warranty Period : 18 months
    • Warranty : 18 months
  • Specifications
    • Country of Origin : Singapore, United States
    • Depth : 114 mm
  • Overview Attributes
    • Device Presentation : point of connection between a group of starters and an automation controller, management of the complete island up to 20 modules